7.0 Cu. Ft. Super Capacity Frontload Electric Dryer
®
Dimensions and Installation Information (in inches)
Electric Dryer Rating
240V
5600W, 24A, 60Hz
208V
4400W, 22A, 60Hz
Exhaust Options: 4-way via rear, right, left and bottom.
Circuit Requirements: An individual, properly grounded
branch circuit, protected by a 30-amp circuit breaker or
a time-delay fuse, is required.
Note: Dryer wall outlet must be located within 36"
of service cord entry and accessible when dryer is
mounted in position.
Installation Information: For complete information, see
installation instructions packed with your dryer.
For answers to your Monogram,
GE Profile
®
GE
®
appliance questions, visit our website at
ge.com or call GE Answer Center
®
800.626.2000.
or
service,
27
31-1/8
Specification Revised 8/09
1-5/8
41-1/2
3-3/4
5-1/2
Listed by
Underwriters
Laboratories
360455

Advertisement

loading

Summary of Contents for GE DCVH680EJMR

  • Page 1 Installation Information: For complete information, see installation instructions packed with your dryer. For answers to your Monogram, GE Profile ® ™ ® appliance questions, visit our website at ge.com or call GE Answer Center service, ® 800.626.2000. 31-1/8 Specification Revised 8/09 1-5/8 41-1/2...
  • Page 2 For more information on venting kits and accessories, please call 1-800-GE-CARES. For answers to your Monogram, GE Profile ® ™ appliance questions, visit our website at ® ge.com or call GE Answer Center ® service, 800.626.2000. Stacked Dimensions (in inches) Specification Revised 8/09 80-1/8 Listed by...
  • Page 3 (crawl space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage. Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of lint and grease could create a fire hazard. Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down. For more information on venting kits and accessories, please call 1-800-GE-CARES. Best performance Maximum length of 4" dia. rigid metal duct Exhaust hood type Number 90°...
  • Page 4 • A nti-Bacteria Option - Certified by the NSF of bacteria • 5 Heat Selections - Offer enhanced drying performance and fabric care • DuraDrum - Provides long-lasting dependability and durability ™ • Damp Dry Signal - Reminds you when to remove select items for hang-drying • Delay Start - Lets you do the laundry on your terms • Model DCVH680EJBB – Black on black • Model DCVH680EJMR – Metallic red • Model DCVH680EJMS – Metallic silver • Model DCVH680EJWW – White on white • Model DCVH680EJMV – Vermillion Red to reduce up to 99% of certain types ® DCVH680J Specification Revised 8/09 360455...

This manual is also suitable for:

Dcvh680ejmsDcvh680ejmvDcvh680ejwwDcvh680ejDcvh680ejbb