DOD SR400D Manual

Digital room delay processor

Advertisement

SR 400D manual
6/8/99
10:54 AM
Page 1
S
Harman Music Group Inc.
Visit DOD on the World Wide Web at http://www.dod.com

Advertisement

Table of Contents
loading

Summary of Contents for DOD SR400D

  • Page 1 SR 400D manual 6/8/99 10:54 AM Page 1 Harman Music Group Inc. Visit DOD on the World Wide Web at http://www.dod.com...
  • Page 2: Warranty

    6. The foregoing is in lieu of all other warranties, expressed or implied, and DOD neither assumes nor authorizes any per- son to assume for it any obligation or liability in connection with the sale of this product. In no event shall DOD or its dealers be liable for special or consequential damages or from any delay in the performance of this warranty due to caus- es beyond their control.
  • Page 3: Table Of Contents

    SR 400D manual 6/8/99 10:54 AM Page 1 Signal Processing Table of Contents Warranty ................................iv Introduction ..............................2 Safety Precautions ............................2 SECTION 1 - GETTING STARTED ........................3 Supplying Power ..............................3 Front Panel Controls ............................3 Bypass Button ..............................3 Mode Button ..............................3 Utility Button..............................4 Display Window ..............................4 Signal / Clip LEDs ............................4 Level Button ..............................4...
  • Page 4: Introduction

    Signal Processing INTRODUCTION Congratulations and thank you for your purchase of the DOD SR 400 D room delay processor. With the SR 400 D room delay, dialing-in the unique sounds and charac- teristics of each venue is a breeze. The SR 400 D lets you enter in information such as Delay time, Room temperature and humidity and then it takes care of all of the calculations for optimizing the sound of the room.
  • Page 5: Section 1 - Getting Started

    Also in this category (but more expensive) are rack mount power supplies. Some of these (such as the DOD 828), have retractable light tubes and RF filtering.
  • Page 6: Utility Button

    SR 400D manual 6/8/99 10:54 AM Page 4 Signal Processing Signal Processing Signal Processing the display to the right when the SR 400 D is in utility mode. 3) UTILITY - This button is used to put the SR 400 D in Utility mode. Once in utili- ty mode, the SR 400 lets you edit functions such as: Temperature, Humidity, delay units, humidity units, Screen contrast and Keyboard lock.
  • Page 7: Channel 2 Xlr Input

    SR 400 D. 6) CHANNEL 2 XLR OUTPUT - This is the Channel 2 Output XLR connector. 7) AC INPUT - Connect the included DOD PS 750 power supply here. SECTION 2 - PROGRAMMING THE SR 400 D Selecting and Editing Delays The SR 400 D is designed to be both easy to program and flexible.
  • Page 8: Mode

    SR 400D manual 6/8/99 10:54 AM Page 6 Signal Processing Signal Processing Signal Processing Mode Selection The Mode selection of the SR 400 D allows you to choose between a 1-In and 2-Out or a 2-In and 2-Out configur- ation. To select either of the two modes, press the <Mode> button and use the <Data Wheel> to change the config- uration mode.
  • Page 9: Temperature

    SR 400D manual 6/8/99 10:54 AM Page 7 Signal Processing Signal Processing Temperature The temperature of a venue also plays a crucial role in affecting the Room delay. The SR 400 D allows you to enter in the current room temperature. Once the correct temperature is entered, the SR 400 D will re-calculate the Room delay so the correct delay is used.
  • Page 10: Declaration Of Conformity

    FAX (801) 566-7005 International Distribution: 3 Overlook Drive, Unit 4 Amherst, New Hampshire 03031 U.S.A. FAX (603) 672-4246 SR 400 D is a registered trademark of DOD Electronics Corporation Copyright © 1997 DOD Electronics Corporation Printed In U.S.A. 3/97 Manufactured in the U.S.A.

Table of Contents