Gas Conversion - Beko Oven Manual

Table of Contents

Advertisement

the bottom by turning left or right and align
level with the work top.
Adjusting the feet of oven
4 feet are supplied together with your oven.
Each foot must be installed into respective
slots located at 4 corners under the oven.
Screw the thread of the foot by turning in
clockwise.
For your safety, make sure that they are level
when screwing all 4 feet. Unbalance of the
legs has negative influence on cooking.
1
Foot
2
Foot slot
Final check
1. Reconnect the product to the mains.
2. Open gas supply.
3. Open gas supply.
4. Check gas installations for secure fitting and
tightness.
5. Ignite burners and check appearance of the
flame.
Flame must be blue and have a regular
shape. If the flame is yellowish, check if the
burner cap is seated securely or clean the
burner.

Gas conversion

DANGER
Before starting any work on the gas
installation, disconnect the gas supply.
There is the risk of explosion!
In order to change your appliance's gas type,
change all injectors and make flame adjustment
for all valves at reduced flow rate position.
15/EN
Gas conversion must only be carried out
by a Gas Safe registered installer or
service agent.
Exchange of injector for the burners
1. Take off burner cap and burner body.
2. Unscrew injectors by turning the counter-
clockwise.
3. Fit new injectors.
4. Check all connections for secure fitting and
tightness.
New injectors have their position
marked on their packing or injector
table on Injector table, page 6 can be
referred to.
1
Flame failure device (model dependant)
2
Spark plug
3
Injector
4
Burner
Unless there is an abnormal condition, do
not attempt to remove the gas burner taps.
You must call an Authorised service agent if
it is necessary to change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted and
turn the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to
adjust the flow rate adjustment screw.
For LPG (Butane - Propane) turn the screw
clockwise. For the natural gas, you should turn the
screw counter-clockwiseonce.
» The normal length of a straight flame in the
reduced position should be 6-7 mm.
4. If the flame is higher than the desired position,
turn the screw clockwise. If it is smaller turn
anticlockwise.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents