Furuno FCV-585 Operator's Manual page 51

Furuno sonar user manual
Hide thumbs Also See for FCV-585:
Table of Contents

Advertisement

FURUNO
3. INTERFACE
3.1
Input Data Sentences
3.2
Output Data Sentences IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0), interval: 2 s
4. POWER SUPPLY
4.1
FCV-620
4.2
FCV-585
5. ENVIRONMENTAL CONDITION
5.1
Ambient Temperature
5.2
Relative Humidity
5.3
Waterproofing and
Dust Proofing
(IEC60529)
5.4
Vibration
6. CHASSIS COLOR
6.1
Display Unit
IEC61162-1 (NMEA0183 Ver 1.5/2.0/3.0)
Order of priority
Latitude/Longitude: GGA>RMC>RMA>GLL
Course (true): VTG>RMC>RMA
Course (magnetic): VTG
Ground speed: VTG>RMC>RMA
Water speed: VHW
Distance to waypoint: BWC>RMB
Bearing to waypoint (true): BWC>RMB
Bearing to waypoint (magnetic): BWC
Heading (true): HDT>VHW
Heading (magnetic): HDG>VHW
Cross track error: XTE>RMB
Atmospheric pressure: MDA
Water temperature: MTW
Wind speed and angle (true/apparent): MWV
DBT, DPT, MTW*, VHW*, TLL* by key operating
*: External data required
12-24 VDC: 0.8-0.4 A
12-24 VDC: 1.0-0.5 A
-15 °C to +50 °C
93 % at 40 °C
IP55
● 2-5 Hz and up to 13.2 Hz with an excursion of ±1 mm ±10 %
2
(7 m/s
maximum acceleration at 13.2 Hz)
● 13.2-100 Hz with a constant maximum acceleration of 7 m/s
Chassis: N-2.5
Bracket: N-1.75
SP - 2
FCV-620/585
2
E2374S01D-M