FURUNO
1.
GENERAL
1.1
TX Frequency
1.2
Transmit Method
1.3
Output Power
FCV-620
FCV-585
1.4
TX Rate
1.5
Pulse-length
1.6
Sensitivity
2.
DISPLAY UNIT
2.1
Display System
FCV-620
FCV-585
2.2
Display Mode
2.3
Expansion Mode
2.4
Basic Range
Unit
1
m
5
ft
15
fa
3
pb
3
HR*
4
2.5
Range Shift
2.6
Zoom Range
2.7
Display Advance Speed 8 steps (Lines/TX; 4/1, 2/1, 1/1, 1/2, 1/4, 1/8, 1/16, Freeze)
2.8
Function Settings
2.9
Display Color
SPECIFICATIONS OF ECHO SOUNDER
FCV-620/585
50 kHz and 200 kHz
Single or dual frequency transmitting
600 W
600 W or 1 kW selectable
Max. 3,000 pulse/min
0.04 to 3.0 ms
10 dBμV
5.6-inch color LCD, 84.7 mm (W) x 113.3 mm (H), 234 x 320 dots
8.4-inch color LCD, 121 mm (W) x 170 mm (H), 480 x 640 dots
Single frequency (high or low freq.), Dual frequency,
Zoom (high or low freq.), Nav data 1/2, A-Scope
Bottom lock, Bottom zoom, Marker zoom
Basic Range
2
3
4
10
20
40
30
60
120
5
10
20
5
10
20
8
15
30
0 to 800 m, 0 to 2,500 ft, 0 to 400 fa, 0 to 450 pb, 0 to 500 HR
Bottom lock expansion: 3 to 10 m, 10 to 30 ft
Bottom and Marker zoom: 2 to 800 m, 7 to 2,500 ft
Pic. Advance, Shift, Interference, Clutter, Color Erase, White Line,
White Marker, WPT List, Bottom Zone
Echo color: 8, 16 or 64 colors according to echo intensity
Background color: White, blue, black, gray or night
5
6
7
80
150
200
200
400
600
40
80
100
50
100
150
50
100
150
*: Japanese unit of depth measurement
SP - 1
FCV-620/585
Setting Range
8
300
2 to 800
1,000
7 to 2,500
150
2 to 400
200
2 to 450
200
2 to 500
E2374S01D-M

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fcv-620

Table of Contents