Download Print this page
GE Profile Performance Advantium SCA2000BCC Quick Manual
GE Profile Performance Advantium SCA2000BCC Quick Manual

GE Profile Performance Advantium SCA2000BCC Quick Manual

Profile performance series
Hide thumbs Also See for Profile Performance Advantium SCA2000BCC:

Advertisement

Quick Links

SCA2000BCC - GE Profile Performance
Dimensional Information (in inches)
66" MIN.
Mounting
height
from
floor
20-1/2"
Door open
Electrical Requirements:
Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts. This
product must be connected to an individual properly grounded branch
circuit, protected by circuit breakers or time delay fuses. Wire size must
conform to the requirements of the National Electric Code or the prevailing
local code for kilowatt rating. The outlet box should be located in the cabinet
above the oven. The supply circuit and outlet box should be installed by a
qualified electrician and conform to all prevailing electrical codes. The wall
outlet receptacle recommended for this appliance is NEMA#14-30R and
accepts the four prong grounded plug of this appliance.
Specification Revised 11/99
Advantium
30"
MIN.
width
Exhaust outlet
required
connects to
3-1/4" X 10" duct
12"
MAX.
14-13/16
16-3/32
15-19/32
Oven
Installation Requirements:
1. A minimum of 30" between the cabinets is required for the installation. If the space
between the cabinets is than 30", a Filler Panel Kit may be used to fill the gap between
the oven and the cabinets. Your Owner's Manual contains the kit number for your model.
2. Make sure the bottom edge of the cabinet that will be above the oven will be at least 66"
from the floor and 30" from the cooking surface.
3. For easier access to change the hood and range lamps, the bottom of the oven should be
at least 2" above the range backsplash.
4. If you are going to vent your oven to the outside, see exhaust duct
preparation instructions.
5. When installing the oven beneath smooth, flat cabinets, be careful to follow the
instructions on the top cabinet template for power cord clearance.
6. For best installation results, we recommend a maximum cabinet depth of 12".
Installation Information: This information is not intended to be used for installing unit described.
Before installing, consult installation instructions packed with product/kit for current dimensional data.
WARNING - PLEASE READ CAREFULLY.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID
SEVERE OR FATAL SHOCK.
Insure proper ground
exists before use.
DO NOT UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR REMOVE ANY OF THE
PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.
NEMA 14-30R
Wall Receptacle
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile
or GE appliance questions, call
GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
R

Advertisement

loading

Summary of Contents for GE Profile Performance Advantium SCA2000BCC

  • Page 1 SCA2000BCC - GE Profile Performance ™ Advantium ™ Oven Dimensional Information (in inches) Installation Requirements: 66" MIN. 1. A minimum of 30” between the cabinets is required for the installation. If the space 30" Mounting MIN. between the cabinets is than 30”, a Filler Panel Kit may be used to fill the gap between...
  • Page 2 SCA2000BCC - GE Profile Performance ™ Advantium ™ Oven Hood Exhaust Duct MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4” x 10” rectangular or Outside ventilation requires a HOOD EXHAUST DUCT. Read the following 6” diameter round duct should not exceed 140 equivalent feet.
  • Page 3 SCA2000BCC - GE Profile Performance ™ Advantium ™ Oven Features and Benefits • Family-Size Oven with Stainless Steel Interior • Speedcook Technology • Over 100 Pre-Programmed Menu Items with Repeat Last, Help and Demo Mode • Electronic Scrolling-Display with Variable Speed Control •...