(7) Bearing accuracy
(8) Range accuracy
(9) Presentation modes
(10) Variable Range Markers
(11) Electronic Bearing Lines
(12) Offcenter
4. POWER SUPPLY
(1) DC Source
FR-1710/1725:
FR-1760DS:
(2) AC Source
FR-1710:
FR-1725:
FR-1760DS:
Display unit:
Antenna power supply unit:100-115 VAC: 3.0 A, 1 phase, 50-60 Hz
5. DIMENSION AND MASS
6. ENVIRONMENTAL CONDITIONS
(1) Ambient temperature (Complies with IEC 945)
(2) Relative humidity
(3) Water proofing
(4) Vibration
(5) Category of Equipment Units
Display unit:
Antenna power supply unit To be installed in a protected area
Antenna unit:
±1°
1% of range in use or 8 m whichever is the greater
Head-up, Head-up TB, North-up, Course-up, True motion north-up
(Gyro signal required except for HU)
Two Variable Range Markers, switchable
Two Electronic Bearing Lines, switchable
Sweep origin can be offcentered by 75% of range in use in any direction
(Not available for maximum range)
24 rpm: 24/32 VDC: 8.5/6.4 A, 42 rpm: 24/32 VDC: 8.8/6.6 A
24 VDC: 5.6 A
100-115/200-230 VAC, 1 phase, 50-60 Hz
2.3 A (24 rpm), 3.2 A (42 rpm)
100-115/200-230 VAC, 1 phase, 50-60 Hz
3.2 A (24 rpm), 3.3 A (42 rpm)
24 VDC: 5.6 A
220/240 VAC, 1 phase, 50-60 Hz (optional rectifier required)
See Outline Drawing
Display unit: -15 to + 55°C
Antenna unit : -25 to + 70°C
95% at 40°C
Display unit (panel): IEC60529 IPX2, Antenna unit: IEC60529 IPX6
±1 mm ±10%, 2(5) to 13.2 Hz,
Maximum acceleration 7 m/s
To be installed in a protected area
To be installed in an exposed area
SP - 3
2
, 13.2 to 100 Hz