Download Print this page

Kenmore 625.388270 Owner's Manual page 23

Water softeners with deluxe valve
Hide thumbs Also See for 625.388270:

Advertisement

[ii:ii,:iii,:iii,:ii
SECTION
5
SERVICE TECH. INFORMATION
A. TROUBLESHOOTING
AUTOMATIC
ELECTRONIC
DIAGNOSTICS
The faceplate
timer
(PWA)
com-
I_lll--_ I
puter
has a self-diagnostic
func-
tion for the electrical
system,
ex-
cept
for input
power
and
water
meter.
The computer
monitors
electronic
compo-
nents and circuits
for correct operation.
Ifa malfunc-
tion occurs,
an error
code appears
in the faceplate
display.
CODE
Err1, Err&
Err4
Err5
The chart
below
shows
the error
codes
that
could
appear,
and the possible
defects
for each code.
While
an error code appears
in the display,
all face
plate buttons
are inoperable
except
the SELECT but-
ton. SELECT remains
operational
so the service
per-
son
can
make
the MANUAL
INITIATED
ELEC-
TRONIC
DIAGNOSTICS
(below)
to further
isolate
the defect,
and check the water
meter.
POSSIBLE DEFECT
MOST LIKELY
_..--'
_,.
LESS LIKELY
motor inoperative / wiring harness or connection to switch / position switch / valve defect causing
hiqh torque
faceplate timer (PWA)
PROCEDURE
FOR REMOVING ERROR CODE FROM FACEPLATE: 1. Unplug
transformer
from outlet 2. Correct
defect
3. Plug in transformer
4. Wait for 8 minutes.
The error code will return if the defect was not corrected.
MANUAL
INITIATED
ELECTRONICS
DIAGNOSTICS
_l_To
enter
diagnostics,
press
the SELECT
button
and hold for three seconds.
You will see the following
display,
showing
valve
cycle
position,
position
switch
status
(open
or
closed),
and turbine
operation.
valve position indicator
indicator (open)
turbine count (water
flowing)
_.
;.......
/¢-._q
[
!
1''U
turbine count (no
water flowing)
TURBINE
OPERATION:
If no
water
is flowing
through
the softener,
the turbine
indicator
displays
three
zeros.
When
water
is flowing,
the flow
bar
scrolls
across
the display,
and a 000 to 199 count
re-
peats
for each gallon
of water
passing
through
the
turbine.
To check
for positive
operation
of the tur-
bine
if zeros
are shown,
open
a nearby
soft water
faucet
and observe
the turbine
count
and flow bar.
If you don't
get a reading
in the display,
with faucet
open,
pull
the sensor
from
the valve
outlet
port.
Pass a small
magnet
back and forth
in front
of the
sensor.
You should
get a reading
in the display.
If
you get a reading,
unhook
the in and out plumbing
and check
the turbine
for binding.
U
POSITION
SWITCH
SENSOR
VALVE
OUTLET
RBINE
RBINE
SUPPORT AND
SHAFT
POSITION
SWITCH
STATUS:
With the valve in ser-
vice, or any of the recharge
cycles, the switch
indica-
tor will show
open
.-,x... While
the valve
is rotating
from
one
position
to another,
the
indicator
will
show
the switch
closed
-,'-.
A defect is probable
if
indications
vary
from this pattern.
5-2
Problems,
Questions?
Call
1-800-426-9345
Kenmore
Water
Line

Hide quick links:

Advertisement

loading