Oki C9500dxn Maintenance Manual page 132

Color led page printer
Hide thumbs Also See for C9500dxn:
Table of Contents

Advertisement

Message
Cause
Service Call
EEPROM not detected
105: Error
at power ON.
Service Call
Error in engine control
106: Error
logic detected at power
ON.
Service Call
Engine ROM
107: Error
check sum error.
Service Call
Option unit for different
110: Error
model detected.
~
110: EnvelopeFeeder
116: Error
111: Duplex unit
112: 2nd Tray
113: 3rd Tray
114: 4th Tray
115: 5th Tray
116: Finisher
Service Call
PU unit fan motor error.
120: Error
Service Call
High-voltage power
121: Error
supply I/F error.
Service Call
Low-voltage power
122: Error
supply fan error.
Low-voltage power
supply temperature error.
Service Call
Improper environment
123: Error
humidity detected by
sensor.
Service Call
Improper environment
124: Error
temperature detected
by sensor.
Service Call
Error detected at MT
125: Error
home position.
Turn power
Sensor dew error.
OFF and wait
126: Dew
error
Service Call
Error detected at the
127: Error
fuser unit cooling fan.
Service Call
Temperature rise
130: Error
detected at LED head.
Service Call
Same unit not detected
131: Y Head
upon power ON or
132: M Head
opening cover.
133: C Head
134: K Head
Service Call
Error detected at
140: Y ID
proper ID position.
141: M ID
142: C ID
143: K ID
41956001TH Rev.1
Table 6-1-1 Operator Alarms (3/6)
Error Description
Does EEPROM exist?
Does error reoccur?
Does error reoccur?
Does error reoccur?
Is error recovered by reloading PU F/W?
Is a proper option unit for the printer set?
1) Is fan in PU unit operating?
2) Error reoccurs after replacing fan motor.
Is cable between PU board andhigh-
voltage power LSI connected properly?
1) Is fan in low-voltage power supply unit
operating?
2) Error reoccurs after replacing fan motor.
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
Sensor dew error detected.
1) Does the fuser unit cooling fan operate?
2) Does the error repeat after fuser unit
cooling fan replacement?
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Is LED head properly set?
3) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
Oki Data CONFIDENTIAL
Solutions
Yes
Check for EEPROM and set if not
found.
Yes
Replace engine control board (K7N).
Yes
Replace engine control board (K7N).
Yes
Reload PU I/F.
No
Replace engine control board (K7N).
Yes
Set proper option unit.
No
Check connections and turn power
ON. If error is not recovered, replace
the unit.
No
Replace fan motor.
Yes
Replace engine control board (K7N).
Yes
Replace engine control board (K7N).
No
Connect properly.
Yes
Replace high-voltage power supply.
Check improper connections for
high-voltage.
No
Replace fan motor.
Yes
Replace low-voltage power supply.
Yes
Replace low-voltage power supply.
Yes
Turn ON power again.
Yes
Replace humidity sensor.
Yes
Turn ON power again.
Yes
Replace humidity sensor.
Yes
Turn ON power again.
Yes
Replace MT.
Turn ON power after a while.
No
Replace the fuser unit cooling fan.
Yes
Replace the engine control PWB (K7N).
Yes
Replace the engine control PWB (K7N).
Yes
Leave alone for 30 min.
Yes
Turn power OFF. Leave for 30 min.,
Yes
then turn power ON. Replace LED
head.
Yes
Confirm that LED head is set properly.
No
Turn power ON again.
Yes
Replace LED head assembly.
Yes
Turn power ON again.
Yes
Replace drum contacct assembly.
132 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9500C9300