Download Print this page

Samsung AM18A1C09 Owner's Instructions & Installation Manual

Multi-split type room air conditioner (cool)
Hide thumbs Also See for AM18A1C09:

Advertisement

Quick Links

MULTI-SPLIT TYPE ROOM AIR CONDITIONER
ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT
CLIMATISEUR DE TYPE MULTIPLE
OWNER'S INSTRUCTIONS &

INSTALLATION MANUAL

MANUAL DE INSTRUCCIONES &
MANUAL DE INSTALACIÓN
MANUEL D'UTILISATION &
MANUEL D'INSTALLATION
Indoor Unit
AM18A1C09
AM26A1C13
AM27A1C13
AM27A1C07
(Refroidissement)
Outdoor Unit
UM18A1C2
UM26A1C2
UM27A1C3
(Cool)
(Refrigeración)

Advertisement

loading

Summary of Contents for Samsung AM18A1C09

  • Page 1: Installation Manual

    OWNER’S INSTRUCTIONS & INSTALLATION MANUAL MANUAL DE INSTRUCCIONES & MANUAL DE INSTALACIÓN MANUEL D’UTILISATION & MANUEL D’INSTALLATION Indoor Unit Outdoor Unit AM18A1C09 UM18A1C2 AM26A1C13 UM26A1C2 AM27A1C13 UM27A1C3 AM27A1C07 MULTI-SPLIT TYPE ROOM AIR CONDITIONER (Cool) ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT (Refrigeración)
  • Page 2 The following safety precautions must be taken when using your air conditioner. Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist.
  • Page 4 UM26A1C2 UM18A1C2 UM27A1C3...
  • Page 6 You have just purchased a multi-split type room air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contain much valuable information on using your air conditioner. Please take the time to read them as they will help you take full advantage of the unit’s features.
  • Page 7 The remote control is supplied with a plastic holder that can be fitted to the wall to hold the remote control when you are not using it. To attach the holder to the wall, proceed as follows. You must insert or replace the remote control batteries when: You purchase the air conditioner The remote control does not work correctly Use two LR03 1 V batteries.
  • Page 8 Your air conditioner contains a clock used to start and stop the unit automatically at a given time. You must set the time when you: Purchase the air conditioner Replace the batteries Be sure to reset the time when you change clocks from standard todaylight savings time and vice versa.
  • Page 9 You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. IMPORTANT...
  • Page 10 You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling IMPORTANT...
  • Page 11 The Turbo cooling function is used to cool your room as quickly as possible. Example: You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
  • Page 12 If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. IMPORTANT...
  • Page 13 If the atmosphere in your room is stale, you can air the room using the Fan feature.
  • Page 14 Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. RECOMMENDATION If you switch the air conditioner...
  • Page 15 You can set the timer to switch the air conditioner on and/or off automatically at given times. Example: You wish to start cooling your room before you return from work; you decide to: Switch the air conditioner on at 5:30 p.m. Switch it off at 11:30 p.m.
  • Page 16 The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. If you wish to switch the unit off at a specific time, refer to page 15. The Quick Timer enables you to set the air conditioner to switch off automatically after a given period of time, by pressing one single button.
  • Page 17 If you no longer wish to use the On/Off Timer that you have set, you can cancel it at any time. If you no longer wish to use the Sleep Timer that you have set, you can cancel it at any time. If you no longer wish to use the Quick Timer that you have set, you can cancel it at any time.
  • Page 18 Here is a recommendation that you should follow when using your air conditioner. The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the cooling operation is used at over 33°C/92°F (indoor temperature) then, does not a full capacity.
  • Page 19 To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you IMPORTANT have switched off the breaker used for the unit. If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly.
  • Page 20 Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call.
  • Page 21 Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken.
  • Page 24 NSTALLATION ANUAL...
  • Page 26 When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Indoor Unit Outdoor Unit You have just purchased a split-type room air conditioner and it has been installed by your installation specialist.
  • Page 27 18,000Btu/h Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
  • Page 28 26,000Btu/h Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
  • Page 29 27,000Btu/h Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.
  • Page 30 The following accessories are supplied with the air conditioner. The quantities are indicated in parentheses. The following connection accessories are optional. If they are not supplied, we recommended that you had better purchase these parts from a shop like home depot before installing the air conditioner. If these accessories are supplied, they are located in the accessory box.
  • Page 31 Before fixing the installation plate to a wall or window frame, you must determine the position of the 65 mm(2 inch) hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit. When facing the air conditioner in position on the wall, the piping and cable can be connected from the: Right Left...
  • Page 32 On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. To prevent dirt or foreign objects from getting into the pipes during installation, do NOT remove the caps completely until you are ready to connect the piping.
  • Page 33 Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the 65 mm(2 inch) hole drilled in the wall, check that none of the following situations occur. To install the drain hose, proceed as follows.
  • Page 34 There are two refrigerant pipes of different diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant A short length of piping is already fitted to the air conditioner. You must extend this piping using assembly piping (optionally supplied). The connection procedure for the refrigerant piping varies according to the exit position of the piping from the indoor unit, as seen when facing the air conditioner in position on the wall:...
  • Page 35 Five metres of piping is supplied with the air conditioner(Optional). This length can if necessary be: Extended to a maximum of ten metres Shortened as required If more than five metres of piping is required: The assembly cable must also be extended Refrigerant must be added to the circuit by an approved installer;...
  • Page 36 Two electric cables must be connected to the outdoor unit: The assembly cable connecting the indoor unit to the outdoor unit. The power cable connecting the auxiliary circuit breaker to the outdoor unit.
  • Page 38 Auxiliary circuit breaker should be installed near outdoor unit so that each access is possible. Main/outdoor power supply cable are connected to upper/lower terminal of auxiliary circuit breaker. It is necessary that the conduit kit for power supply to the outdoor unit be installed between auxiliary power s/w and the outdoor unit.
  • Page 39 If the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner.
  • Page 40 The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour. If it is to be installed in a location exposed to strong winds or at a height, the unit must be fixed to an appropriate support (wall or ground).
  • Page 41 The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction. Refrigerant for air purging is not charged in the outdoor unit. Use Vacuum Pump as shown at the right figure.
  • Page 42 Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate.
  • Page 43 To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly.
  • Page 44 The remote control is supplied with a plastic holder that can be fitted to the wall to hold the remote control when it is not being used. Choose a position where: The signal from the remote control will not be blocked (by a curtain for example) The remote control is not exposed to direct sunlight or heat The remote control is at least one metre away from a television...
  • Page 46 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS...

This manual is also suitable for:

Am26a1c13Am27a1c13Am27a1c07Um18a1c2Um26a1c2Um27a1c3