Omron Micro A-I-R NE-U22 Instruction Manual

Omron Micro A-I-R NE-U22 Instruction Manual

Mesh nebulizer

Advertisement

EN-p2-20-(NE-U22)-3
I N S T R U C T I O N M A N U A L
MESH NEBULIZER
NE-U22
Model
Thank you very much for purchasing
OMRON Mesh Nebulizer.
Be sure to read this Instruction Manual
before using the unit for you to use it
safely and correctly.
Keep this Instruction Manual always at
hand for your future reference.
This unit is a medical instrument. Be sure to follow the instructions of a doctor and use the unit correctly.
For the type, dose, and regimen of medication, be sure to follow the instructions of a doctor.
This unit is not appropriate to use as a household inhalator for humidifying the mucous membranes of throat and nose.
The nebulization characteristics of this unit differ by the properties of medication. Especially with the use of a medication
having high surface activity or viscosity such as medication solubilizing agent or expectorant, the nebulization rate may be
reduced. The nebulization rate may also be reduced when the temperature of medication is low.
This unit cannot nebulize distilled water.
3/25/02
4:48 PM
Page 1
The electromagnetic compatibility of this unit conforms to the Medical
Electric Instrument EMC Standard IEC60601-1-2 (1993 version).
The illustrations in this Instruction Manual are image drawings.
Before Using the Unit
Notes on Safety . . . . . . . . . . . . . . . . . . . . . 2
Product Features . . . . . . . . . . . . . . . . . . . . 5
Product Contents. . . . . . . . . . . . . . . . . . . . 5
Correct Use of the Unit
How to Fill the Medication . . . . . . . . . . . . 12
How to Inhale. . . . . . . . . . . . . . . . . . . . . . 15
How to Disinfect the Unit
How to Disinfect. . . . . . . . . . . . . . . . . . . . 18
How to Replace the Mesh Cap . . . . . . . . 19
Troubleshooting
How to Carry the Unit . . . . . . . . . . . . . . . 20
Troubleshooting . . . . . . . . . . . . . . . . . . . . 21
Specifications / Option parts . . . . . . . . . . 22

Advertisement

Table of Contents
loading

Summary of Contents for Omron Micro A-I-R NE-U22

  • Page 1: Table Of Contents

    How to Disinfect....18 OMRON Mesh Nebulizer. How to Replace the Mesh Cap ..19...
  • Page 2: Notes On Safety

    • They may be broken and cannot be used or you may suffer electric shock. Do not use the AC adapter other than the one supplied by Omron. Do not use a broken AC adapter. (AC adapter is an optional part.) •...
  • Page 3: Product Features

    Product Contents Please check the product. The following items are contained in the box. If any item is missing, please contact the store where you purchased the product or the nearest OMRON dealer. 1. Main Unit 2. Main Unit 3. Medication 4.
  • Page 4: Names And Functions Of The Parts

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 4 Names and Functions of the Parts Mesh Cap An alloy mesh is installed for nebulization. - Mesh Cap is consumable. Mesh Cap Cover A figure viewed Protects the Mesh. from the above Medication Port Fill the medication by opening the Mesh Cap.
  • Page 5 EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 5 Nebulization Port Do not insert your Nebulize medication here. finger into the A figure viewed Nebulization Port. from the rear Mesh Efficient nebulization is realized from the minute pores. - Mesh is an extremely minute part. Handle it carefully.
  • Page 6: How To Assemble The Main Unit

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 6 How to Assemble the Main Unit First, check how to assemble the unit. You must assemble the unit before starting to use it. You may find the parts slightly hard to assemble because they are made to prevent the medication from leaking.
  • Page 7 EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 7 3 Install the Mask Adapter Installation is to the Main Unit. complete. Securely cover the Main Unit with the Mask Adapter. Install the Mouthpiece or the Inhalation Mask (S) or (L) to the Mask Adapter.
  • Page 8: How To Prepare The Power Source

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 8 How to Prepare the Power Source Connect the unit to the power source before starting to use it. Use batteries or optional AC Adapter as the power source. How to use the optional AC Adapter Please note that this AC Adapter is not a battery charger.
  • Page 9 EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 9 How to Insert Batteries Batteries are not supplied. Use two commercially available AA alkaline batteries. You can also use nickel-hydrogen batteries (rechargeable batteries). If you use a commercially available battery charger, you can save cost by recharging the batteries repeatedly.
  • Page 10: How To Fill The Medication

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 10 How to Fill the Medication Remove the Mask Adapter, Mouthpiece, or Inhalation Mask (S), then fill the medication. 1 Remove the Medication Bottle from the Main Unit. Lift up the Medication Bottle by pushing in the Medication Bottle Disengaging Buttons on both sides and releasing the engagement.
  • Page 11 EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 11 5 Install the Medication Bottle to the Main Unit. Align both - If the Medication Bottle is not Electrodes with installed correctly, the power will not each other. turn on. - If the Electrodes are extremely stained, the unit will not nebulize normally.
  • Page 12: How To Select The Nebulization Mode

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 12 How to Select the Nebulization Mode You can select the nebulization mode by the way how you push the Button. Continuous Nebulization Mode If you push the Button and immediately lift your finger away from the Button...
  • Page 13: How To Inhale

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 13 How to Inhale 1 Hold the Main Unit with your hand and start inhalation in relaxed posture. Slightly slant the Main unit (the Medication side of Button) towards yourself. Immerse the Vibrator in the medication.
  • Page 14: How To Clean The Unit After Inhalation

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 14 How to Clean the Unit after Inhalation Be sure to clean and store the unit after inhalation. If you do not clean the unit after inhalation, medication will be dried and adhered, and will not nebulize normally the next time. If this happens, clean the Mesh Cap by boiling to wash off the adhered medication.
  • Page 15 EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 15 4 Dry the parts thoroughly. Immediately after washing the parts, wipe off water with new gauze and dry them thoroughly. General advice Do not insert your Never try to wipe off water with tissues finger into the Nebulization Port.
  • Page 16: How To Disinfect

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 16 How to Disinfect This unit can be easily cleaned and disinfected because the Medication Bottle and the Mesh Cap can be removed from the Main Unit. The unit can be disinfected with benzalkonium chloride.
  • Page 17: How To Replace The Mesh Cap

    You can usually use a Mesh Cap for approximately 1 year (according to the test result of OMRON). However, the unit may not nebulize even before using it a year depending on how you use it. The unit also may not nebulize or nebulize extremely weak even after disinfected by boiling.
  • Page 18: How To Carry The Unit

    EN-p2-20-(NE-U22)-3 3/25/02 4:48 PM Page 18 How to Carry the Unit You can carry the with the Mouthpiece or the Inhalation Mask in the Storage Bag. - When carrying the unit, cover the Main Unit with a Main Unit Cover.
  • Page 19: Troubleshooting

    The Electrode of the Main Unit Wipe off the stain. (Refer to Page 15.) is stained. If the unit does not nebulize normally after taking the above-mentioned procedure, contact the store where you purchased the unit or the nearest OMRON dealer.
  • Page 20: Specifications / Option Parts

    U22-3: Medication U22-4: Mesh Cap U22-5: AC Adapter U22-7: Storage Bag Bottle (With a mesh) For the inquiry on where to purchase the option parts, contact the store where you purchased the unit or the nearest OMRON dealer.

Table of Contents