9200 Power Supply
This document discusses the installation and specifications for the following
9200 meter power supply options:
!
Standard AC/DC power supply
!
Low voltage DC power supply
480V power supply
!
In This Document
Installing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
!
Wiring the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
!
Wiring the Standard AC/DC or Low Voltage DC Power Supply . . . . . . . . . . . . . . 3
Wiring the 480V Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Powering Up the Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
!
Additional Information
9200 Installation and Operation Guide
!

Advertisement

loading

Summary of Contents for Siemens 9200

  • Page 1 9200 Installation and Operation Guide © 2003 Siemens Energy & Automation. All rights reserved. The information in this document is believed to be accurate at the time of publication, however, Siemens Energy & Automation assumes no responsibility for errors which may...
  • Page 2: Replacing The Power Supply

    (if you are replacing an existing power supply). Fit the power supply plug-in connector to the meter plug-in port. All 9200 power supply models are installed the same way; the diagram for the 480V power supply is included to show the greater depth dimension of that model.
  • Page 3: Wiring The Power Supply

    9200 Power Supply Retrofit Instructions Wiring the Power Supply Wiring the Power Supply The meter requires a constant power supply to maintain monitoring, analysis, control, and communications operations. Powering the device from the voltage source it is monitoring is not suitable for applications where these operations must be maintained in the event of a power outage.
  • Page 4: Powering Up The Meter

    Wiring the 480V Power Supply 9200 Power Supply Retrofit Instructions Wiring the 480V Power Supply Use18 to 14 AWG (0.8mm to 2.1mm ) wires Use18 to 14 AWG (0.8mm to 2.1mm ) wire Connections to the L1 and L2 terminals...
  • Page 5: Specifications

    9200 Power Supply Retrofit Instructions Specifications Specifications Maximum Steady State Dielectric Power Supply Rated Inputs Meter Withstand Integrated AC: 100 – 240 VAC, 50 – 60 Hz Standard AC / DC DC: 110 – 300 VDC 2000 VAC RMS, TRAN / RMD Power Supply Installation category II (Local).