CLEARANCE DIMENSIONS
SPECIAL WARNING
For complete information in regard to installation of
Only qualified personnelshould
Jenn-Air range, see figures 1, 2, 3 and 4. For SAFETY
install or service this range.
CONSIDERATIONS, do not installa range in any
combustible cabinetrywhichis not in accord with the
installationclearancesshownin figure 1.
Read "Safety Instructions" in Use &
Care book before using range.
CAUTION:
This range has been designed in
accordance with the requirements of various safety
Improper installation, adjustment,
agencies and complies with the maximum allowable
wood cabinet temperatures of 194°F. If this range
alteration, service, maintenance
or
is installed with cabinets that have a lower working
use of range can result in serious
temperature than 194°F, discoloration,delamination
or melting may occur.
injury or property damage.
Your range may notbe equipped I
WARNING
w,th some of the features referred I
). ALALusRA;GERSIEsCA;
pT/RPsoANsD,
to in this manual,
I
• INSTALL
ANTI-TIP
DEVICES
PACKED WITH RANGE.
ENGLISH
I_
PP. 1-11
• FOLLOW ALL
INSTALLATION
ESPAI;IOL
I)
pan. 12-22
INSTRUCTIONS.
FRANCAIS
_
p, 23-33
8101 P427-60
(I0-01-00)

Advertisement

loading

Summary of Contents for Jenn-Air 8101P427

  • Page 1 SPECIAL WARNING For complete information in regard to installation of Only qualified personnelshould Jenn-Air range, see figures 1, 2, 3 and 4. For SAFETY install or service this range. CONSIDERATIONS, do not installa range in any combustible cabinetrywhichis not in accord with the installationclearancesshownin figure 1.
  • Page 2: Installation Drawings

    INSTALLATION DRAWINGS (Pages 2, 3 & 4) IMPORTANT PLEASE KEEP FOR THE USE OF THE-LOCAL ELECTRICAL INSPECTOR. CLEARANCE BETWEEN ,M]JACENT COMBUSTIBLE COI¢STRUCTIOI_ AriD TH£ BACK AND SIDe'S OF" THE RANGE BELOW ,HE COOKING SURFACE. _ql# 92_f>'l ts FIGURE 1 NOTE: Figure may not be representative of actual unit. The 30 inches (76.2 cm) minimum clearance between the installing a range hood that projects horizontally a top of the cooking surface and the bottom of an...
  • Page 3 MAY[AG C0 M Bring innovation home. 30" JENN-AIR RANGES _ WHEN REPLACING AN EXISTING UNIT, A MAXIMUM CUT DEPTH 1/2" (59.7 IS ACCEPTABLE. X< "F" "nrpT__ p' _ NOTE: EORMEO FRONT EDGE. ._T_ "C__ "t ON COUNTER TOPS WITH SHAVE RAISED...
  • Page 4 MAYFAG_. C 0 M Bring innovation home. _M 30" JENN-AIR RANGES Unity IISlide-In Range Dimensions • Inches Centimeters 63.5 61.0 76.2 91.4 235/8 60.0 5 1/2 14.0 25.4 23 1/4 59.1 29 7/8 75.9 K 2* 263/16 66.5 353/4 90.8...
  • Page 5: Mobile Homes

    MOBILE HOMES LOCATING THE RANGE The installation of a range designed for mobile home Place range in a well lit area. Do not set range over holes installation must conform with the Manufactured Home in the floor or other locations where it may be subject to Construction and Safety Standard, Title 24 CFR, Part strong drafts.
  • Page 6 STEP 2 - Ant|-TiD Bracket Installstion Opti_ls STEP 3 - Ranqe Installation A. Wood Construction: A. A Jenn-Air range may be installed by one person. 1, Floor: Locate the center of the two holes identified in figure 5 as "HOLES FOR FLOOR." Drifta 1/8"...
  • Page 7: Connecting The Range

    CONNECTING THE RANGE ELECTRIC SUPPLY RANGE CONNECTIONS The range must be installedin accordancewith Localand Some modelsare shippeddirect from the factory with NationalElectric Code (NEC) ANSI/NFPA No. 7C-latest servicecords(pigtails)attached.There are no range edition.See rating plate for total connectedKW rating, connections necessary on these models.Just plug into the range outlet.
  • Page 8 3-WIRESERVICECORD OR CONDUIT 4-WIRESERVICECORDOR CONDUIT INSTALLATION INSTALLATION 1. Insure that the copper ground strap IS CONNECTED (MOBILE HOMES OR AS REQUIRED BY CODES) between the middle post of the main terminal 1. The copper ground strap connected between the connection block and the range chassis, neutral (middle) post of the main terminal block and the chassis MUST be cut off as shown in figure 9.
  • Page 9 3. Make cutout in the cabinet floor of either the right or INLET left side cabinet as shown in figures 14 or 15. _,,,_"--._. --r--"- L_uc---m_- cm) - (32.71_ ¢m} 4. Relocate the mounting brackets on the blower | r_/J./////J_///_ _ ;==_..-.J- rililUi|TL[- - housing as shown in figure 17.
  • Page 10: Range Installation

    8. Install the 6" (15,24 cm) elbow of the blower housing INSTALLING THE BLOWER and secure with duct tape. The open end of the elbow I NOTE: shouldbe pointedto the left. Attach the 6" (15.24 cm) Install the blower prior to installing flex duct (providedwith the range) to the elbowand to I range.