Step 10 Installing Trim, Logs, And Ember Material; Installing The Trim; Positioning The Logs; Shutter Setting - Quadra-Fire QV-ST Installer's Manual

Table of Contents

Advertisement

Step 10. Installing Trim, Logs,
and Ember Material

Installing the Trim

Combustible materials may be brought up to the specified
clearances on the side and top front edges of the fireplace,
but MUST NEVER overlap onto the front face. The joints
between the finished wall and the fireplace top and sides
can only be sealed with a 300° F. (149° C) minimum sealant.
WARNING: WHEN FINISHING THE FIREPLACE,
!
NEVER OBSTRUCT OR MODIFY THE AIR INLET/
OUTLET GRILLES IN ANY MANNER.
Install optional marble and brass trim surround kits as
desired. Marble, brass, brick, tile, or other non-combustible
materials can be used to cover up the gap between the
sheet rock or wood and the fireplace.
Do not obstruct or modify the air inlet/outlet grilles. When
overlapping on both sides, leave enough space so that the
bottom grille can be lowered and the trim door removed.

Positioning the Logs

If the gas logs have been factory installed they should not
need to be positioned. If the logs have been packaged
separately, refer to the instructions that accompany the
logs. Save the log instructions with this manual.
If sooting occurs, the logs might need to be repositioned
slightly to avoid excessive flame impingement.
Shutter Settings
NG
LP
___________________________________________
Burner
3/8”
Set
GLASS SPECIFICATIONS:
Glass
Model
Type
QV-ST
TEMPERED
QV-PIER
TEMPERED
Village Collection gas fireplaces manufactured with tempered
glass may be installed in hazardous locations such as bath-
tub enclosures as defined by the CPSC. The tempered glass
has been tested and certified to the requirements of ANSI
Z97.1-1984 and CPSC 16 CFR 1202. (Safety Glazing Certi-
fication Council SGCC # 1595 and 1597. Architectural Test-
ing, Inc. Reports 02-31919.01 and 02-31917.01.)
This statement is in compliance with CPSC 16 CFR Sec-
tion 1201.5 “Certification and labeling requirements” which
refers to 15 USC 2063 stating “…Such certificate shall ac-
company the product or shall otherwise be furnished to any
distributor or retailer to whom the product is delivered.”
Some local building codes require the use of tempered glass
with permanent marking in such locations. Glass meeting
this requirement is available from the factory. Please con-
tact your dealer or distributor to order.

Placing the Ember Material

Ember material is shipped with this gas fireplace. The bag
labeled Golden Ember (GE-93) is flame colorant material.
The bag labeled Glowing Ember (050-721) is standard glow-
ing ember material.
To place the ember material:
• Remove the wing nuts and glass clips or tension springs
around the glass door.
• Remove the glass door from the unit.
• Place dime size pieces of ember material about 1/2 inch
apart near port holes in burner top. Do NOT press em-
bers into burner ports. Cover the top of the burner with a
single layer of ember material. For best performance do
NOT place embers on the ports at the rear of the burner.
• Save the remaining ember materials for use during fire-
place servicing. The bag of embers provided is sufficient
for 3 to 5 applications.
• Replace the wing nuts, glass clips, and screws.
• Replace the glass door and a front trim door on the unit.
• Hand tighten the wing nuts.
CAUTION: IT IS STRONGLY RECOMMENDED THAT
TRIM DOORS WITH OPTIONAL MESH SCREENS BE
INSTALLED ON PROPANE MODELS.
Figure 35. Placement of the Ember Material
Page 31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qv-pierIllage qv-stIllage qv-pier