GenReady™
GenReady™ Load Center Features
The GenReady load center is a hybrid panel that operates as a normal load center and
also allows for seamless integration of standby generators. It is available in a NEMA
1 configuration for indoor installations, or in a NEMA 3R configuration for outdoor
applications. For installation flexibility, it is multi-listed for use with multiple breaker
manufacturers.
• 200 amp
• 40 circuit capacity with the use of tandem breakers
• Multi listed for use with Siemens, Square D and GE 1" breakers
• Dimensions are the same as a standard 42-space main load center
• Utilizes standard Siemens components
• Protect up to 18 circuits, up to 30 with the use of tandem breakers
• 10 circuits available for non-protected loads
• Circuits can easily be shifted from protected to non-protected and vice versa
• ETL listed for service equipment and consumer safety
• Models available with or without EZ Transfer Operator™ factory installed
• Single panels are compatible with generators rated up to 125 Amps/30 kW
• Multiple GenReady load centers can be supported with a single generator
• Flush Mount NEMA 1 Enclosure or NEMA 3R Enclosure
EZ Transfer Operator™ Features
• Factory installed on the GenReady Advanced model. Can be easily installed in the
field on the GenReady Basic with available kit
• Allows for manual or automatic operation
Please Note: The GenReady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer's generator may
require the purchase and installation of additional sensing and control components.
GenReady™ Series
Load Centers and Transfer Switch
Model 005448-2 (NEMA 1 Basic)
Model 005449-2 (NEMA 1 Advanced)
Model 005453-2 (NEMA 3R Basic)
Model 005454-2 (NEMA 3R Advanced)
Model 005447-0 (EZ Transfer Operator™)
®
1 of 4

Advertisement

loading

Summary of Contents for Generac Power Systems GenReady Series 005448-2

  • Page 1 EZ Transfer Operator™ Features • Factory installed on the GenReady Advanced model. Can be easily installed in the field on the GenReady Basic with available kit • Allows for manual or automatic operation Please Note: The GenReady Panel is designed to be directly compatible with any Generac manufactured product. Use of another manufacturer’s generator may require the purchase and installation of additional sensing and control components.
  • Page 2 ® GenReady™ Load Centers and Transfer Swtich Load Center Product Options NEMA 1 NEMA 1 NEMA 3R GenReady™ Advanced Load Center with GenReady™ Advanced Load Center with GenReady™ Basic Load Center Model Number 5448 EZ Transfer Operator™ EZ Transfer Operator™ Model Number 5449 Model Number 5454 2 of 4 Includes: Includes GenReady Basic plus: Includes GenReady Basic plus: • 125A Circuit Breaker • E Z Transfer Operator • E Z Transfer Operator • 1 25A Lower Panel • 1 25A Lower Panel, • 1 25A Lower Panel, Circuit Switch...
  • Page 3 ® GenReady™ Load Centers and Transfer Swtich Dimensions 15.63 14.875 14.38 3 of 4 Outside Dimensions Outside Dimensions of Enclosure Shell of Enclosure Shell Front Cover & Door 43.25 14.38 NEMA 1 NEMA 3R Equipment Ground Utility Bonding Generator Transfer Operator Connection Neutral...
  • Page 4: Specifications

    ETL listed ......................................Yes Seismically qualified to meet UBC code ............................. Yes Weight – GenReady Basic w/o EZ Transfer Operator (GenReady Advanced with EZ Transfer Operator) ......................45.5 lbs. (49 lbs.) Operating temperature range ............................-20º F to 140º F Installation Options GenReady™ Basic GenReady™ Advanced GenReady™ Complete The GenReady load center is installed The GenReady load center is installed with Everything included in the GenReady without the EZ Transfer Operator. It replaces the EZ Transfer Operator. All fuel and electri- Advanced level is installed along with an the home’s main load center. This option will cal lines (contractor supplied) are installed automatic standby generator. The home’s save the homeowner thousands in upgrade to the planned generator site along with the selected circuits will be backed up by gen- costs when a generator is installed. generator pad (if required). The home is erator power whenever the utility is lost. completely wired and ready for the addition of a generator in the future. The NEMA 3R GenReady installation is similar but is suitable for outdoor installations. ® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com ©2012 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0175200SBY-J Printed in U.S.A. 12/12/12...

This manual is also suitable for:

Genready series 005454-2Genready series 005449-2Genready series 005453-2Genready series 005447-0Genready 5448Genready 5449 ... Show all