D. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specifi ed. Framing or fi nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
Combustible Mantels
TO CEILING
18
12
11
10
32
9
8
25
7
19
6
18
5
17
4
16
3
15
14
13
12
2-1/2
11
10
5
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
Note: All measurements in inches.
Note: Measurement is taken from top of the
opening, NOT the top of the fi replace.
Figure 5.3 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles
Combustible Mantel Legs or Wall Projections
INTERIOR WALL
TOP VIEW
A
B
FIREPLACE OPENING
MANTEL LEG OR WALL PROJECTIONS
A
B
If
minimum is ____, then
maximum is_____.
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Inches
A
62
87
113
138
164
189
Millimeters
1
2
3
4
5
Inches
B
25
51
76
102
127
Millimeters
The CMOD door will overlap the appliance. See Figure
5.5 and 5.6.
Figure 5.5 Appliance Surround
3/8 IN.
1-3/4 IN.
3/8 IN.
Figure 5.6 Door Overlaps Surround