Summary of Contents for Heat & Glo 7000XLT

  • Page 5 ITEM / SERIAL # / N° DE PART NUMBER STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE PIÈCE SÉRIE / N° DE PIÈCE Robertshaw Valve Valve NG / Valve GN 060-522 Valve LP / Valve PL 060-523 Pilot Assembly NG / Module de veilleuse GN 485-510A Pilot Assembly LP / Module de veilleuse PL 485-511A...
  • Page 7 ITEM / SERIAL # / N° PART NUMBER STANDING PILOT IGNITION / ALLUMAGE UNE VEILLEUSE PIÈCE DE SÉRIE / N° DE PIÈCE Valve Assembly NG / Module de Valve GN 389-005A Valve Assembly LP / Module de Valve PL 389-006A Valve NG / Valve GN 060-522 Valve LP / Valve PL...
  • Page 10 TOP STANDOFFS TOP VENT COLLARS HOOD TRIM DOOR RATING PLATE LINE AND LABELS ACCESS ELECTRICAL ACCESS CONTROLS...
  • Page 13 8 5/8” (220mm) DV-45D 35 3/4” 47 3/4” (908mm) (1.2m) 11 3/4” (298mm) 8 3/4” 5 3/4” (222mm) (146mm) DV-09D DV-12D DV-06D...
  • Page 14 VERTICAL TERMINATION STORM COLLAR ROOF FLASHING HORIZONTAL HORIZONTAL PIPE DVK-01D DVK-TVCD TERMINATION SUPPORT PIPE LENGTH DVK-01TRD WALL FIRESTOP CEILING WALL BRACKET 90 DEGREE FIRESTOP ELBOW...
  • Page 18 STARTING COLLAR STOVE SEALANT BEAD FIRST VENT COMPONENT 1 INCH (25.4mm)
  • Page 20 12" (305mm) 12" (305mm) 1" (25.4 mm) VENT PIPE HEAT SHIELD TRIM HEAT SHIELD IF TOO LONG, ADD TO SHIELD IF TOO SHORT EXTERIOR FIRESTOP INTERIOR FIRESTOP...
  • Page 21 JOIST CEILING NAILS (4 REQUIRED) CEILING FIRESTOP 11" (280 mm) 11" (280mm) CHIMNEY HOLE NAILS (4 REQUIRED) EXISTING CEILING JOISTS FRAMING MEMBERS CEILING RAFTER CEILING CEILING FIRESTOP...
  • Page 22 ROUND CAP TERMINATION PERFORATION CANNOT BE INSIDE THE WALL 7 1/2" (191mm) MINIMUM TRAPEZOID CAP TERMINATION 7 1/4" (184mm)
  • Page 23 openable fixed closed J or K 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4...
  • Page 24 HORIZONTAL OVERHANG 2 FT. 2 FT. MIN. VERTICAL MIN. WALL LOWEST DISCHARGE OPENING TERMINATION ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING...
  • Page 26 USE A WRENCH ON SHUT-OFF VALVE WHEN TIGHTENING GAS LINE MANUAL CONTROL SHUT-OFF VALVE VALVE GAS VALVE GAS LINE FLEX ACCESS HOLE CONNECTOR...
  • Page 27 BLACK S2 REMOTE SWITCH 3/16” PIGGYBACK CONNECTOR PIGTAIL ON/OFF WHITE T2 SWITCH GAS VALUE RED T1 THERMOPILE THERMOCOUPLE OPTIONAL WALL SWITCH, BLACK S1 THERMOSTAT OR REMOTE VARIABLE SPEED CONTROL NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 C RATED WIRE.
  • Page 28 CEILING 12" 11" 10" 9" 31” 8" 7" 6" 12” 5" 11” 10” 4" 9” 3" 8” 7” 2" 6” 5” 4" 3” 2” TOP FRONT EDGE OF FIREPLACE...