Heat & Glo 6000TRS-CE Installer's Manual
Hide thumbs Also See for 6000TRS-CE:

Advertisement

Model:
6000TRS-CE
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed
by a qualified installer, service agency, or the
gas supplier.
This is a room sealed appliance and no other ventilation is
required than what is provided.
Please contact your Heat & Glo dealer with any questions or
concerns. For the number of your nearest Heat & Glo dealer,
please visit www.heatnglo.com.
Printed in U.S.A. Copyright 2013
Heat & Glo, a brand of Hearth & Home Technologies
7571 215
Street West, Lakeville, MN 55044, USA
th
This product is covered by one or more of the following patents: (United States) 5601073, 5613487, 5647340, 5890485, 5941237, 6006743, 6019099, 6053165,
6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending.
1
READ THIS MANUAL BEFORE INSTALLING OR
OPERATING THIS APPLIANCE. THIS INSTALLERS
GUIDE MUST BE LEFT wITH APPLIANCE FOR FUTURE
REFERENCE.
Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13
wARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
These instructions are only valid if the following country symbol is
on the appliance. If this symbol is not present on the appliance,
it is necessary to refer to the technical instructions which will
provide the necessary information concerning the modification
of the appliance to the conditions of use for the country.
These instructions are valid for the following countries: GB, IE
Installers Guide
0086
2000-945B

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6000TRS-CE

  • Page 1 This product is covered by one or more of the following patents: (United States) 5601073, 5613487, 5647340, 5890485, 5941237, 6006743, 6019099, 6053165,  6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 2: Safety And Warning Information

    Any safety screen or guard removed for servicing must be replaced before operating this appliance. This appliance is intended for use on a gas installation with a governed meter. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 3: Table Of Contents

    Step 12 Lighting the Fireplace ........38 After the Installation ........38 Section 4: Maintaining and Servicing Your Fireplace ..........39 Section 5: Troubleshooting .........41 Limited Lifetime Warranty ..........44  = Contains updated information. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 4: Service Parts List

    6000TRS-CE Service Parts 36” Gas Fireplace - Dv Beginning Manufacturing Date: Jan 2004 Ending Manufacturing Date: Active Log Set Assembly Part number list on following page. 03/13 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 5 Glass Latch Assembly Pkg of 2 33858/2 High Temp Limit Switch 046-018A Exhaust Restrictor 530-299 Mineral Wool 050-721 Touch-Up Paint TUP-GBK-12 Additional service part numbers appear on following page. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 6 Natural to Propane NGK-6TRS-CE Propane to Butane LPK-6TRS-CE Butane to Propane BGK-6TRS-CE Regulator N 230-1570 Regulator P/B 230-1520 Pilot Orifi ce N 529-512 Pilot Orifi ce P/ B 200-2630 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 7: Section 1: Approvals And Regulations

    This appliance must be installed with the rules in force, and used only in a sufficiently ventilated space. Consult instructions before installation and use of this appliance. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 8: Section 2: Getting Started

    Heat & Glo Fireplace Products, Inc., not withstanding any independent testing laboratory or other party approval of such component part or accessory. ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 9 FRONT VIEW RIGHT SIDE Location Centimeters Location Centimeters 104,1 54,6 91,8 29,7 85,1 72,4 87,9 36,2 21,6 24,6 68,3 21,6 15,2 dia 101,9 91,8 Figure 1. Diagram of the 6000TRS-CE Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 10: Section 3: Installing The Fireplace

    For Horizontal Sections at wall firestops For vertical Sections Bottom Sides Bottom Sides 7.6 cm 2.54 cm 2.54 cm 2.54 cm 6.4 cm 1.3 cm 2.54 cm Figure 3. Minimum Clearances Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 11: Step 2 Framing The Fireplace

    THE ELBOW FOR THE ENTIRE WIDTH AND DEPTH (BEHIND THE FRONT HEADER) OF THE FIREBOX. 107 cm 102 cm 56 cm 68,3 cm 106 cm Figure 4. Framing Dimensions Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 12: Step 3 Installing The Flue System

    HORIZONTAL TERMINATION HORIZONTAL PIPE SUPPORT PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP FLUE SYSTEM TERMINATION KITS DVP-SERIES DVP-TVHW DVP-TRAP Figure 5. Flue Components and Terminations Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 13 1.3 cm TYP 31.9 cm NOTE: PIPES OVERLAP 3,2 cm AT EACH JOINT. Figure 6. DVP-Series Balanced Flue Component Specifications (127 mm inner pipe / 203 mm outer pipe) Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 14 11.8 m MAX. Figure 7. Straight up vertical Flue STRAIGHT OUT HORIZONTAL FLUE MIN. RUN MAX. RUN 13.1” (33.2 cm) 24” (61.0 cm) Figure 8. Straight Out Horizontal Flue Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 15 NOTE: If a 90º elbow is first attached to the unit, the maximum horizontal run is 3 feet (91.4 cm). Figure 10. Flue with One 90° Elbow Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 16 MAX. 1.22 m MAX. 3.72 m MIN. 1.22 m MAX. 1.8 m MAX. 4.9 m MAX. 6.1 m MAX. 1.8 m MAX. 4.9 m Figure 11. Flue with Two 90° Elbows Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 17 MAX. 3.7 m MIN. 1.22 m MAX. 4.9 m V+H+H = MAX. 11.8 m = MAX. 4.9 m = MAX. 12.97 m Figure 12. Flue with Two 90° Elbows Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 18 MAX. 1.22 m MAX. 3.6 m MIN. 1.22 m MAX. 1.86 m MAX. 4.9 m MAX. 6.1 m MAX. 1.86 m MAX. 4.9 m Figure 13. Flue with three 90° elbows Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 19 MIN. 1.22 m MAX. 4.9 m V + V + H + H = MAX. 10.97 m H + H = MAX. 4.9 m Figure 14. Flue with three 90° elbows Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 20: Installing Flue Components

    Insert screwdriver or similar object Out Top Out Rear here to remove cap. SEAL INSULATION, SEAL DISCARD BOTH PIECES HEAT SHIELD HEAT DISCARD SHIELD INSULATION CUT HERE Figure 15 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 21 To install support brackets for horizontal runs: • Place the pipe supports around the flue pipe. • Nail the pipe supports to the framing members. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 22 • The pipe opening of the firestops MUST BE placed towards the bottom of the firestop. • Continue the flue run through the firestop. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 23 • Frame the hole with framing lumber the same size as the ceiling joists. 10" (25.4 cm) ” CHIMNEY HOLE EXISTING CEILING JOISTS FRAMING MEMBERS CEILING Figure 19. Hole and New Framing Members Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 24: Flue Termination

    • One section of the heat shield is attached to the wall shield. The other is attached to the termination cap in the same manner (see Figure 22). Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 25 THE TERMINATION CAP MUST BE POSITIONED SO THAT THE ARROw IS POINTING UP. • Use a high-temperature sealant gasket to seal between the pipe and exterior firestop. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 26 Place non-hardening mastic around the joint, between the storm collar and the vertical pipe. • Slide the termination cap over the end of the flue pipe and snap into place. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 27 45.0°-49.4° ..........1.52 49.4°-53.1° ..........1.83 53.1°-56.3° ..........2.13 56.3°-59.0° ..........2.29 59.0°-60.3° ..........2.44 *.91 M minimum in snow regions Figure 24. Minimum Height from Roof to Lowest Discharge Opening Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 28 Figure 25 vent Termination Minimum Clearances cauTiON: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 29: Securing The Fireplace

    230 vAC MUST NEvER BE CONNECTED TO A CONTROL vALvE IN A MILLIvOLT SYSTEM. STANDING PILOT Figure 27. Gas Control System Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 30: Step 6 The Gas Supply Line

    The gas line should be installed by a qualified service technician. GAS LINE ACCESS Figure 28 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 31: Step 7 Gas Pressure Requirements

    Position the wall switch in the desired position on a wall. Run a maximum of 780 cm or less length of 0.102 cm diameter minimum wire and connect it to the fireplace ON/OFF switch pigtails. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 32: Step 9 Finishing

    MODIFY THE AIR INLET/OUTLET GRILLES IN ANY MANNER. Note: Factory installed non-combustible board may only be replaced with HHT product code SUPERM-60 material and must be fully replaced in its entirety. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 33: Step 10 Installing Trim, Logs & Ember Material

    See following pages for log installation instruction. Figure 32. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 34: Positioning The Logs

    LOG #2 (SRV2049-701): Locate the bottom grooves of log #2 over the second and third grate bars. Push back against the grate tabs on these bars. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 35 Push log #5 against the grate tabs on the 5th grate bar and rest its top in the groove on log #1. If sooting occurs, the logs might need to be repositioned slightly to avoid excessive flame impingement. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 36: Placing The Ember Material

    • Save the remaining ember materials for use during fireplace servicing. • Replace the glass door and a front trim door on the unit (see Replacement Parts Section of the manual.) • Replace the latches and tension springs. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 37: Step 11 Before Lighting The Fireplace

    Remove and clean the glass. Replace the glass and run the fireplace for an additional 8 hours. This will help to cure the products used in the paint and logs. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 38: Step 12 Lighting The Fireplace

    USER’S MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE. After the LEAvE THIS INSTALLATION MANUAL wITH Installation THE APPLIANCE FOR FUTURE REFERENCE. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 39: Section 4: Maintaining And Servicing Your Fireplace

    NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 40 MAKE SURE THE FLAMES ARE STEADY—NOT LIFTING OR FLOATING. Figure 35. Burner Flame Patterns STANDING PILOT Figure 36. Pilot Flame Patterns Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 41: Section 5: Troubleshooting

    Be sure the wire connections from the thermopile at the gas valve terminals are tight and that the thermopile is fully inserted into the pilot bracket. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 42 Clean and adjust the pilot flame for maximum outage problem. flame impingement on thermocouple. high or too low, or blowing Follow lighting instructions carefully. (high), causing pilot safety to drop out Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 43 Ensure that the glass is tightened properly on the unit, particularly on top corners. Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 44: Limited Lifetime Warranty

    3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...
  • Page 45 THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • 6000TRS-CE • 2049-900 Rev. R • 3/13...

Table of Contents