WARNING:
IF THE INFORMATION IN THESE
INSTRUCTIONS IS NOT
FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
- Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
- What to do if you smell gas
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier,
call the fire department.
- Installation and service must be
performed by a qualified installer,
service agency, or the gas supplier.
Printed in U.S.A.
Copyright 1997,
Heat-N-Glo Fireplace Products, Inc.
6665 West Highway 13, Savage, MN 55378
Underwriters Laboratories Listed
READ THIS MANUAL BEFORE INSTALLING
OR OPERATING THIS APPLIANCE. THIS
INSTALLERS GUIDE MUST BE LEFT WITH
APPLIANCE FOR FUTURE REFERENCE.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE
OR MAINTENANCE CAN CAUSE INJURY
OR PROPERTY DAMAGE. REFER TO
THIS MANUAL. FOR ASSISTANCE OR
ADDITIONAL INFORMATION CONSULT A
QUALIFIED INSTALLER, SERVICE
AGENCY, OR THE GAS SUPPLIER.
This appliance may be installed in an
1.
aftermarket, permanently located,
manufactured (mobile) home, where
not prohibited by local codes.
2. This appliance is only for use with the
type of gas indicated on the rating
plate. This appliance is not convertible
for use with other gases, unless a
certified kit is used.
Please contact your Heat-N-Glo Fireplace dealer for any
questions or concerns. For the number of your nearest
Heat-N-Glo dealer, please call 612-890-8367.
Installers Guide
Patents Pending

Advertisement

Table of Contents
loading

Summary of Contents for Heat-N-Glo AT-GRAND

  • Page 1 Installers Guide Model: AT-GRAND Patents Pending Underwriters Laboratories Listed READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS WARNING: INSTALLERS GUIDE MUST BE LEFT WITH IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT APPLIANCE FOR FUTURE REFERENCE. FOLLOWED EXACTLY, A FIRE...
  • Page 7: Minimum Fireplace Size

    SURROUND ON/OFF SWITCH VOLTAGE WIRES MINIMUM FIREPLACE SIZE FRONT WIDTH: 33” (839mm) REAR WIDTH : 24” (610mm) 13 1/2 TOP VIEW DEPTH : 13 ” (343mm) HEIGHT : 24” (610mm) NOTE: If exhaust collar on insert and fireplace damper do not line up, add 4 inches (102mm) to minimum fireplace height for bends in vent pipe.
  • Page 11 This option shows both exhaust and TERMINATION CAP inlet air vent pipes attached the adaptor. ADAPTOR EXHAUST VENT PIPE V= 14FT. MINIMUM 50FT. MAXIMUM WARNING: Do not block pipe end with insulation or any other sealing material. INLET AIR VENT PIPE...
  • Page 14 USE A WRENCH ON USE A WRENCH ON SHUT-OFF VALVE WHEN SHUT-OFF VALVE WHEN TIGHTENING GAS LINE. TIGHTENING GAS LINE. MANUAL SHUT-OFF MANUAL SHUT-OFF VALVE VALVE GAS VALVE FLEX CONNECTOR...
  • Page 17 FAN WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE NOTE: IF ANY OF THE ORIGINAL WIRE VARIABLE SPEED CONTROL AS SUPPLIED WITH THE APPLIANCE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE MUST BE REPLACED, IT MUST BE REPLACED WITH TYPE 105 DEGREE C REPLACED WITH TYPE 105 DEGREE C RATED WIRE.
  • Page 18 GLASS DOOR...
  • Page 19 FIREBOX SURROUND WITH TRIM SURROUND TRIM DOOR ON/OFF SWITCH VOLTAGE WIRES Figure 12...
  • Page 20 12” MAX. MANTEL 12” MAX. TOP OF UNIT Figure 13...

Table of Contents