  • Page 1 PRO PLUS PORTABLE WHEELCHAIR SCALE MODEL 2450KL BALANCE PORTATIVE PRO PLUS POUR FAUTEUIL ROULANT MODELE 2450KL BALANZA PORTABLE PRO PLUS PARA SILLA DE RUEDAS MODELO 2450KL OPERATION MANUAL MODE D'EMPLOI MANUAL DE OPERACIÓN...
  • Page 2: Table Of Contents

    PRO PLUS PORTABLE WHEELCHAIR SCALE MODEL 2450KL Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference. Merci d'avoir acheté ce produit. Veuillez lire attentivement ce manuel et le garder à portée de main pour pouvoir le consulter à tout moment Gracias por la adquisición de este producto.
  • Page 3: Caution And Warning

    AC power source as soon as possible. SPECIFICATIONS GENERAL Health o meter’s Pro Plus Portable Wheelchair Scale Model 2450KL uses highly sophisticated microprocessor technology. Each precision instrument is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient.
  • Page 4: Set Up

    SET UP Parts List: (1) Scale Assembly (1) AC Adapter (1) Display Assembly (1) Load Cell Cable (4) Plastic Feet Assemblies Tools required: Phillips head screwdriver. Remove each assembly from the carton and unwrap packing material carefully to prevent scratching the unit’s parts. Figure 1.
  • Page 5 SET UP Figure 2a Figure 2b Tighten the width adjusting knob in order to lock the width adjusting mechanism. Remove the stand at the rear of the display assembly by unscrewing 4 screws, in order to connect load cell cable and power cord to the display assembly (see Figure 3). Connect the load cell cable connector to the load cell port on the rear of the display assembly and insert and secure the cable into the center channel in the display.
  • Page 6 Remove protective plastic film from keypad and display. Place batteries in the battery holder (see “Replacing Batteries”). Plug the scale’s AC adapter into the power source. Press the ON/OFF button to turn the scale on. The display will show “Health o Meter Pro-Plus” and then ”000 ”.
  • Page 7: Operation Instructions

    OPERATION INSTRUCTIONS Press the ON/OFF button to turn the scale on. Wait until ”000 ” and “ZERO” on the left side of the display will appear. Bring the wheelchair close to the scale ramps. Unscrew the width adjusting knob and adjust the scale width by moving the left ramp.
  • Page 8 OPERATION INSTRUCTIONS Figure 5. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. Holds the value of the weighed object on the display until HOLD/RELEASE the button is pressed again to clear the value. Also used to scroll down in the menu.
  • Page 9 OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys ( ) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the menu and presses the down button, it will return to the top of the menu.
  • Page 10 OPERATION INSTRUCTIONS TARE WEIGHT NOTE: Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a wheelchair, shoes, etc): press MENU (1) and select option 02-Tare Weight or press TARE (9).
  • Page 11 OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4.
  • Page 12 OPERATION INSTRUCTIONS Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values. If the transfer was unsuccessful, the values are kept in memory until successfully transferred or cleared. Clear memory All the values stored in memory will be cleared.
  • Page 13 OPERATION INSTRUCTIONS Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity. Default time is 10 minutes. If the value is set to zero, the auto off function is disabled. Tone Volume There is an option to adjust the beeping tone of the scale.
  • Page 14 OPERATION INSTRUCTIONS Display Backlight The user can set the brightness of the backlight. Display Contrast The user can set the brightness of the LCD. Live Weight By selecting “Yes” the user can set the Live Weight mode to deactivate the motion-sensing mode. In the Live Weight mode the weight displayed will fluctuate with the patient’s movement;...
  • Page 15 OPERATION INSTRUCTIONS Set the date using the up and down keys and enter the values on the keypad. About This screen displays the software version of the scale. SYSTEM TEST Battery Test The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced.
  • Page 16 OPERATION INSTRUCTIONS UI Test The scale has a diagnostic routine where it tests the User Interface (UI) hardware functionality (LCD, keypad). In order to do this the user has to press all the keys according to the messages displayed on the screen. If the requested command was not received or wrong button was pressed, the following message will be displayed.
  • Page 17 OPERATION INSTRUCTIONS Disp Height & ID When the user selects to display the height and ID of the user, it will be displayed at the bottom of the screen. We recommend the use of this function to ensure that the patient’s correct ID and height have been entered.
  • Page 18: Maintenance

    MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the Pro Plus Portable Wheelchair Scale Model 2450KL. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of non-use, check the scale for proper operation and function.
  • Page 19: Troubleshooting

    TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on Dead Battery Replace batteries Faulty electrical outlet Use a different outlet Bad power supply Replace adapter Questionable weight or External object...
  • Page 20: Calibration Path

    X.XXXXX Press ENTER Calibration Please clear the scale Please remove weight from the scale platform Rebooting Please wait 10. Please wait until the scale resumes normal Health O Meter operation Pro Plus EXPLODED VIEW OF SCALE...
  • Page 21 EXPLODED VIEW OF SCALE (continue)
  • Page 22: Parts List

    PARTS LIST Key No. Part No. Description Qty. 1109402-0 DISPLAY ASSEMBLY 3824801-0 HEAD STAND PHIL. PAN HEAD SCREW NC8-32*5/16” 2033702-0 MAIN BOARD TO CONNECTION CABLE PHIL. PAN HEAD SCREW NC6-32*1/4” 2138902-0 RIGHT CONNECTION DIGITAL BOARD COUNTERSUNK PHIL. HEAD SCREW M4*6 3825201-0 LOAD CELL MOUNTING PLATE 1304202-0...
  • Page 23: Warranty

    7400 West 100th Place, Bridgeview IL 60455 • 1-800-638-3722 or 1-708-598-9100 www.healthometermedical.com Health o meter ProPlus products are manufactured, designed and owned by Pelstar LLC. Health o meter® is a registered trademark of Sunbeam Products Inc., Boca Raton, FL 33431. ProPlus is a trademark of Pelstar LLC...