installation & Operating Manual
P43 Pellet Stove Owners Manual
"Ce manuel est disponible en Français sur demande"

SaFetY nOtice

PleaSe Read thiS entiRe Manual beFORe YOu inStall and uSe YOuR new ROOM heateR. FailuRe
tO FOllOw inStRuctiOnS MaY ReSult in PROPeRtY daMage, bOdilY injuRY, OR even death.
FOR uSe in the u.S. and canada. Suitable FOR inStallatiOn in MObile hOMeS.
iF thiS haRMan StOve iS nOt PROPeRlY inStalled, a hOuSe FiRe MaY ReSult. FOR YOuR SaFetY, FOllOw
inStallatiOn diRectiOnS.
cOntact lOcal building OR FiRe OFFicialS abOut ReStRictiOnS and inStallatiOn inSPectiOn
ReQuiReMentS in YOuR aRea.
cOntact YOuR lOcal authORitY (Such aS MuniciPal building dePaRtMent, FiRe dePaRtMent, FiRe
PReventiOn buReau, etc.) tO deteRMine the need FOR a PeRMit.
cette guide d'utiliSatiOn eSt diSPOnible en FRancaiS. chez vOtRe cOnceSSiOnnaiRe de haRMan
hOMe heating.
R1
Save theSe inStRuctiOnS.
1
P43 Pellet Stove
3-90-04301R18_03/13

Advertisement

Table of Contents
loading

Summary of Contents for Harman P43

  • Page 1: Safety Notice

    & Operating Manual P43 Pellet Stove Owners Manual “Ce manuel est disponible en Français sur demande” SaFetY nOtice PleaSe Read thiS entiRe Manual beFORe YOu inStall and uSe YOuR new ROOM heateR. FailuRe tO FOllOw inStRuctiOnS MaY ReSult in PROPeRtY daMage, bOdilY injuRY, OR even death.
  • Page 3 76mm min 3" min 9"(228mm) 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 4: Table Of Contents

    The P43 Pellet Stove has huge features in a small package, giving you 0 to 43,000 BTU when you need it, automatically. You basically need to set your desired room temperature and fill the hopper. With the P43 you will notice even heat throughout your zone and a level of convenience you never thought possible.
  • Page 5 SeRvice PeRSOn. PeRiOdic cleaning SPeciFicallY aPPROved FOR Such iS ReQuiRed thROughOut the heating inStallatiOn. SeaSOn and at the end OF each winteR FOR the StOve tO wORk eFFicientlY. See cleaning inStRuctiOnS On Pg 23. 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 6: Installation

    The P43 is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping. To free the stove from the skid you must remove the hold-down bolts in the rear of the pedestal base.
  • Page 7 Measurement "K" is measured from waRning the glass in the US ONLY the StRuctuRal integRitY OF the canada ManuFactuRed hOMe FlOOR, wall, and ceiling/ROOF MuSt be Maintained. loor protector dO nOt inStall in SleePing ROOM. 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 8 Inside Corner Detail Fixed Porch or Deck Closed Openable Fixed Openable or Fixed Closed Openable Sidewalk =Vent Terminal =Air Supply Inlet =Area where termination is mot permitted P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 9 & home technologies strongly recommends increaser Part #3PvP-X4adhb are highly recommended attaching outside air in all installations, especially lower to be installed on the starter collar to insure a proper pipe connection to the unit. level and main floor locations. 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 10: Vent Configurations

    To install outside air use 2 3/8" I.D. non-combustible flex pipe. There is a break-away hole on the rear Direct Vent Wall Passthrough Kit panel of the P43 stove which must be removed before (part #1-00-677077) connecting the flex pipe. The pipe should be run outside and terminate to the side or below the vent pipe outlet so the flue outlet is more than 12"...
  • Page 11 (such as grass, leaves, etc.) at least 3 feet away from the flue outlet on the outside of the building. 3 Ft. 12" min. wall to outlet Fig. 9 to combustibles 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 12: Venting

    The connector pipe should extend through the smoke chamber to the base or into the first flue tile. Be sure to design the venting so that it can be easily cleaned. Fig. 11 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 13 The pipe or liner inside the chimney should be 4" diameter. In this method a cap should also be installed on the chimney to keep out rain. Fig. 13 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 14 #8 installing through the ceiling Fig. 15 Through the ceiling vent, follow PLvent manufacturers recommendations when using wall and ceiling pass through. note: do not place joints within wall pass-throughs. 12" min. wall to outlet Fig. 16 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 15: Esp Control

    P43 automatic ignition eSP control Feed adjuster Sets the maximum Power Light feed rate. Indicates power to the control. Test Runs all motors at full speed for one minute Status Light to check operation. Will be lit in either stove...
  • Page 16 P43 automatic ignition / Operation The P43 is a fully automatic stove that features two Room temperature Mode operating modes; Stove Temperature Mode and Room Temperature Mode. In Stove Temperature Mode, you select a burn rate and the stove will remain at the same burn rate regardless of the room temperature.
  • Page 17 P43 automatic ignition / Operation Stove temperature Mode out. The fire will not go out immediately and may take In the Stove Temperature Mode and with the igniter more than an hour to fully shut down. toggle switch in the Auto position, the stove will light...
  • Page 18 P43 automatic Start up Starting First Fire igniter Switch to"autO"(up position) Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit. SeeHint #7. Fig. 17 Flame Guide nOtice: be sure there is no unburned fuel 1"...
  • Page 19: Automatic Operation

    P43 Manual ignition / Operation The P43 Pellet Stove is capable of manual operation. This also allows the operator to manually control operation during an emergency (i.e. igniter failure, when using a 502H battery backup, as opposed to the 512H, or when using certain generators.) The unit can be switched between "AUTO"...
  • Page 20 P43 Manual Start up Starting First Fire igniter Switch to"Manual" (down position) Fig. 20 Make sure the unit is plugged into a 120 VAC, 60 HZ electrical source. The power light should be the only light lit. Fig. 19 nOtice: be sure there is no unburned fuel See Hint #7.
  • Page 21: Low Draft Voltage Adjustment

    1. Plug unit into a 120VAC, 60 HZ outlet. for firebox tightness, gasket leakage, motor operation and igniter operation. The P43 is then factory set at a 2. Close the hopper lid, front view door, and the ash mid-point adjustment and in most cases will not need pan.
  • Page 22: Maintenance

    & hOMe technOlOgieS. • inStallatiOn OF PaRtS OR cOMPOnentS nOt SuPPlied OR aPPROved bY heaRth & hOMe technOlOgieS. • OPeRating aPPliance withOut FullY aSSeMbling all cOMPOnentS. OR anY Such actiOn that MaY cauSe a FiRe hazaRd. P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 23 4. Scrape burnpot with flat end of scraper provided with the stove. Inspect the holes on the burnpot surface. Blower Cover See Fig. 33. Latch 5. Open burn pot clean-out. Clean fly ash from burn pot Fig 27 and replace cover. 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 24 The stove should be cleaned after damage ESP probe each ton of pellets (50 bags) and the venting system when cleaning with inspected and cleaned after each heating season. brush. Probe Fig. 31 Fig. 33 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 25: Burn Pot Cleaning And Maintenance

    P43 Maintenance - burn Pot burn Pot cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot.(Fig 33) It is not necessary to completely remove all material from the burn pot. The excess will be pushed out during the next use.
  • Page 26: Safety Features

    P43 Maintenance - cleaning the Feeder body Pellet fines may accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this area must be performed. To clean out fines: 5/16" Hex Head 5/16" Hex Head Screws (2 on 1.
  • Page 27: Troubleshooting

    4. The holes in the burnpot may be getting filled with and all others at 3% or more. ash or carbon buildup. The P43 is capable of burning all 3 categories of pellets 5. Combustion blower fan blades may need cleaned. due to a patented feeder and burn pot system.
  • Page 28 Flue Size 3 inch Outside Air Size " i.d. inch Fuse Rating 6 amp P43 wiring diagram HARMAN P43/P61A/P68 PELLET STOVE WIRING DIAGRAM MALE/FEMALE CONNECTIONS BROWN WHITE GREEN WIRE IS GROUND REMOTE SENSOR PORTS 6 AMP GLASS FUSE BONDED TO STOVE BODY...
  • Page 29: Options

    This will allow the swell latch of the hopper extension to fully expand to the bottom side of the hole for a proper seal. 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 30: Warranty

    Damp pellet fuel could turn back into sawdust which does not flow properly through the feed system. P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 31 Loosen these two wing screws for access to clean the air passage and igniter. For P38+ model, follow Stove Temp instructions. Keep feed rate on #3 or above when using a wall thermostat. P43 Pellet Stove...
  • Page 32 Addendum Minimizing Smoke During Loss of Power Using Battery Back-up Harman strongly recommends installing battery back-up to minimize entry of smoke into the room in the event of power loss. Your pellet/biomass burning appliance relies on a combustion blower to remove exhaust. A power failure will cause the combustion blower to stop.
  • Page 33 1 year Burners, logs and refractory years Limited 3 years Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645F 02-18-13 Page 1 of 2 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 34: Warranty Conditions

    THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE. 4021-645F 02-18-13 Page 2 of 2 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 35: Service Parts

    1-90-04300-2 (charcoal)(june 2011) 1-90-04300-5 (honey glo) (june 2009) 1-90-04300-3 (goldenfi re) (june 2011) 1-90-04300-10 (Mojave Red) (jan 2010) 1-90-04300-4 (Metallic blue) (jan 2010) 1-90-04300-12 (Forest green) (jan 2010) 11 12 Part number list on following page. 01/13 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 36 3-40-900450-414 Hopper Heat Shield 2-00-773854B Feeder Cover 2-00-773826L Circuit Board w/Knobs & Shafts 1-00-05886 Control Board Label 3-90-06655A Circuit Board Plate, Studded w/label 1-10-08327 Knob, Contol Board/D-Shaft 25 Sets 1-00-015605 Additional service parts on following page. P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 37 Silicone Tubing, 1/8" 5 Ft 1-00-5113574 Airwash O-Rings Pkg of 10 1-00-939639 Arrow Burn Pot Scraper Pkg of 10 2-00-773850-10 Cradle Assembly Igniter Holder, Cradle, & Flat Bottom 3 Sets 1-00-06620 Additional service parts on following page. P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 38 Bright Nickel 3-43-06802-8 Gold 3-43-08400 Ash Lip Trim Brushed Stainless 3-43-08400-7 Bright Nickel 3-43-08400-8 Gold 3-43-06729-4 Tile Frame Brushed Stainless 3-43-06729-7 Bright Nickel 3-43-06729-8 Spring Clips (Required for installation of Tile Frame) Pkg of 20 3-31-232547-20 P43 Pellet Stove 3-90-04301R18_03/13...
  • Page 39 Service & Maintenance log Date Of Service Performed By Description Of Service 3-90-04301R18_03/13 P43 Pellet Stove...
  • Page 40 At Harman, we build each product to a standard, not a price. This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels. (Signature of Boxer) Your premium quality hearth product designed and assembled by the experienced and skilled members at Harman in Halifax, PA, USA.

Table of Contents