Download Print this page

Regular Maintenance; If Your Smoke/Co Alarm Sounds; What To Do First-Identify The Type Of Alarm; If The Co Alarm Sounds - First Alert SCO5 User Manual

Combination carbon monoxide & smoke alarm
Hide thumbs Also See for SCO5:

Advertisement

REGULAR MAINTENANCE

This unit has been designed to be as maintenance-free as possible, but there
are a few simple things you must do to keep it working properly.
Use only the replacement batteries listed below. The unit may not
operate properly with other batteries. Never use rechargeable batteries
since they may not provide a constant charge.
Test it at least once a week.
Clean the Smoke/CO Alarm at least once a month; gently vacuum the
outside of the Smoke/CO Alarm using your household vacuum's soft
brush attachment. A can of clean compressed air (sold at computer or
office supply stores) may also be used. Follow manufacturer instructions
for use. Test the Smoke/CO Alarm. Never use water, cleaners or solvents
since they may damage the unit.
If the Smoke/CO Alarm becomes contaminated by excessive dirt, dust
and/or grime, and cannot be cleaned to avoid unwanted alarms, replace
the unit immediately.
Relocate the unit if it sounds frequent unwanted alarms. See "Where This
Alarm Should Not Be Installed" for details.
Choosing a replacement battery:
Your Smoke/CO Alarm requires two standard AA batteries. The following
batteries are acceptable as replacements: Eveready Energizer E91. These
batteries are available at many local retail stores.
Actual battery service life depends on the Smoke/CO Alarm and the environ-
ment in which it is installed. All the batteries specified above are acceptable
replacement batteries for this unit. Regardless of the manufacturer's suggested
battery life, you MUST replace the battery immediately once the unit starts
"chirping" (the "low battery warning").
To replace the batteries (without removing
Alarm from the ceiling or wall):
1. Open the battery compartment.
2. Press tabs A and B as shown in the diagram
and remove each battery.
3. Insert the new batteries, making sure they
snap completely into the battery compartment.
Match the terminals on the ends of the
batteries with the terminals on the unit.
4. Close the battery compartment, and then test
the unit by pressing the Test/Silence button.

IF YOUR SMOKE/CO ALARM SOUNDS

WHAT TO DO FIRST–IDENTIFY THE TYPE OF ALARM
Type of Alarm
Carbon Monoxide (CO)
Smoke

IF THE CO ALARM SOUNDS

"ALARM-MOVE TO FRESH AIR"
If you hear the CO alarm horn and the CO red light is flashing, move
everyone to a source of fresh air. DO NOT remove the batteries!
Actuation of your CO Alarm indicates the presence of carbon monoxide
(CO) which can kill you. In other words, when your CO Alarm sounds,
you must not ignore it!
IF THE CO ALARM SIGNAL SOUNDS:
1. Operate the Test/Silence button.
2. Call your emergency services, fire department or 911. Write down the
number of your local emergency service here:
__________________________________________________________________
3. Immediately move to fresh air—outdoors or by an open door or window.
Do a head count to check that all persons are accounted for. Do not re-
enter the premises, or move away from the open door or window until the
emergency services responder has arrived, the premises have been aired
out, and your CO Alarm remains in its normal condition.
4. After following steps 1-3, if your CO Alarm reactivates within a 24-hour
period, repeat steps 1-3 and call a qualified appliance technician to inves-
tigate for sources of CO from fuel-burning equipment and appliances, and
inspect for proper operation of this equipment. If problems are identified
during this inspection have the equipment serviced immediately. Note any
combustion equipment not inspected by the technician, and consult the
manufacturers' instructions, or contact the manufacturers directly, for more
information about CO safety and this equipment. Make sure that motor
vehicles are not, and have not, been operating in an attached garage or
adjacent to the residence. Write down the number of a qualified appliance
technician here:
__________________________________________________________________
A B
What You See and Hear
CO LED: Flashes Red
Horn: 4 beeps, pause, 4 beeps, pause
Power/Smoke LED: Off
Power/Smoke LED: Flashes Red
Horn: 3 beeps, pause, 3 beeps, pause
CO LED: Off

IF THE SMOKE ALARM SOUNDS

RESPONDING TO AN ALARM
If the unit alarms and you are not testing the unit, it is warning you
of a potentially dangerous situation that requires your immediate
attention. NEVER ignore any alarm. Ignoring the alarm may result in
injury or death.
Never remove the batteries from a battery operated Smoke/CO
Alarm to stop an unwanted alarm (caused by cooking smoke, etc.).
Removing batteries disables the alarm so it cannot sense smoke,
and removes your protection. Instead open a window or fan the
smoke away from the unit. The alarm will reset automatically.
If the unit alarms get everyone out of the house immediately.
WHAT TO DO IN CASE OF FIRE
• Don't panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don't stop to get
dressed or collect anything.
• Feel doors with the back of your hand before opening them.
If a door is cool, open it slowly. Don't open a hot door. Keep doors
and windows closed, unless you must escape through them.
• Cover your nose and mouth with a cloth (preferably damp).
Take short, shallow breaths.
• Meet at your planned meeting place outside your home,
and do a head count to make sure everybody got out safely.
• Call the Fire Department as soon as possible from outside.
Give your address, then your name.
• Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer.
Alarms have various limitations. See "General Limitations of Smoke/CO
Alarms" for details.

USING THE SILENCE FEATURES

Never remove the batteries to quiet an unwanted alarm. Removing the
batteries disables the alarm and removes your protection.
The Silence Feature is intended to temporarily silence the horn while you identify
and correct the problem. Do not use the Silence Feature in emergency situations.
It will not correct a CO problem or extinguish a fire.
The Silence Feature can temporarily quiet an unwanted alarm for several minutes.
Press the Test/Silence button on the alarm cover for at least 3-5 seconds.
After the Test/Silence button is released, the Red LED blinks during the silence
mode.
When the Smoke Alarm is Silenced
The Smoke Alarm will remain silent for
up to 15 minutes, then return to normal
operation.
If the smoke has not cleared–or
continues to increase–the device
will go back into alarm.
SILENCING THE LOW BATTERY WARNING
This silence feature can temporarily quiet the low battery warning "chirp" for up
to 8 hours. Press the Test/Silence button on the alarm cover.
Once the low battery warning "chirp" silence feature is activated, the unit
continues to flash the Green light twice a minute for 8 hours. After 8 hours, the
low battery "chirp" will resume. Replace the batteries as soon as possible;
this unit will not operate without battery power!
To deactivate this feature: Press the Test/Silence button again. The unit will go
into Test Mode and the low battery warning will resume (LED flashes and unit
sounds "chirp" once a minute).
NOTE: A qualified appliance technician is defined as "a person, firm, corporation,
or company that either in person or through a representative, is engaged in and
responsible for the installation, testing, servicing, or replacement of heating,
ventilation, air conditioning (HVAC) equipment, combustion appliances and
equipment, and/or gas fireplaces or other decorative combustion equipment."
4
When the CO Alarm is Silenced
The CO alarm will remain silent for
up to 4 minutes.
After 4 minutes, if CO levels remain
potentially dangerous the horn will
start sounding again.

Hide quick links:

Advertisement

loading