BATTERY OPERATED CARBON MONOXIDE ALARM
WITH DIGITAL DISPLAY AND SILENCE FEATURE
Printed in Mexico
M08-0157-007 P 08/10
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your Carbon
Monoxide (CO) Alarm's operation. If you are installing this CO Alarm for use
by others, you must leave this manual-or a copy of it-with the end user.

TABLE OF CONTENTS

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Understanding Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Using the Peak CO Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . . . . . . . .2
How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . . . . . . . .4
How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Potential Sources of CO in the Home . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Underwriters Laboratories Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
© 2010 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005
www.brkelectronics.com • www.firstalert.com
USER'S MANUAL
LISTED TO
UL 2034
Model CO410
STANDARD

INTRODUCTION

BASIC SAFETY INFORMATION

Dangers, Warnings, and Cautions alert you to important operating
instructions or to potentially hazardous situations. Pay special
attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to detect
carbon monoxide from ANY source of combustion. It is NOT designed
to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences.
It is NOT designed for marine use.
This CO Alarm will only indicate the presence of carbon monoxide gas
at the sensor. Carbon monoxide gas may be present in other areas.
The Silence Feature is for your convenience only and will not correct
a CO problem. Always check your home for a potential problem after
any alarm. Failure to do so can result in injury or death.
NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to
"If Your CO Alarm Sounds" for more information. Failure to do so
can result in injury or death.
Test the CO Alarm once a week. If the CO Alarm ever fails to test
correctly, have it replaced immediately! If the CO Alarm is not working
properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of family
living units. It is not designed to measure CO levels in compliance
with Occupational Safety and Health Administration (OSHA) commer-
cial or industrial standards. Individuals with medical conditions that
may make them more sensitive to carbon monoxide may consider
using warning devices which provide audible and visual signals for
carbon monoxide concentrations under 30 ppm. For additional infor-
mation on carbon monoxide and your medical condition contact your
physician.

HOW YOUR CO ALARM WORKS

GENERAL INFORMATION
This Co Alarm does not operate without working batteries. Removing
the batteries, or failure to replace them at the end of their service
life, removes your protection.
High temperatures, low temperatures, high humidity, impact or
dropping can adversely affect LCD displays.
A CO Alarm measures the CO levels in the air. It will alarm if CO levels rise
quickly (if the heat exchanger on your furnace breaks, for example), or if CO
is consistently present (a slow CO leak on a fuel-burning appliance).
This carbon monoxide alarm features a permanently installed sensor, three
colored indicator lights, and an 85 dB alarm horn. It also has a silence feature
to temporarily quiet the alarm horn.
THE PARTS OF YOUR CO ALARM
2
5
1 Open door here
2 Test/Silence Button
3 POWER/ALARM Light (Green/Red)
4 Battery Compartment
1
6
7
1
3
4
5 (Behind Cover) Alarm Horn: 85dB
audible alarm for test, alarm,
and unit malfunction warning.
6 Peak Level Button
7 Digital Display

Advertisement

loading

Summary of Contents for First Alert KV-T29SN81 CO410

  • Page 1: Table Of Contents

    Failure to do so can result in injury or death. LISTED TO • NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to UL 2034 Model CO410 “If Your CO Alarm Sounds” for more information. Failure to do so STANDARD can result in injury or death.
  • Page 2: Understanding Your Co Alarm

    UNDERSTANDING YOUR CO ALARM Lights blink when batteries are first connected. DIGITAL DISPLAY: All segments are turned on for a short time upon initial power. Then the battery level icon is displayed. ALARM RECEIVING BATTERY POWER Green light flashes every minute. Horn is silent. DIGITAL DISPLAY: Battery icon will show a full or almost full icon.
  • Page 3: How To Install Your Co Alarm

    HOW TO INSTALL YOUR CO ALARM Read “Where To Install CO Alarms” before starting. Before you start installation, find the pair of self-adhesive labels included with this CO Alarm. On each label write in the phone number of your emer- gency responder (like 911) and a qualified appliance technician.
  • Page 4: Testing And Maintenance

    TESTING & MAINTENANCE WEEKLY TESTING • Test the CO Alarm once a week. If the CO Alarm ever fails to test correctly, have it replaced immediately! If the CO Alarm is not working properly, it cannot alert you to a problem. •...
  • Page 5: Potential Sources Of Co In The Home

    Fuel-burning appliances like: portable heater, gas or wood burning fireplace, gas kitchen range or cooktop, gas clothes dryer. Damaged or insufficient venting: corroded or disconnected water heater vent pipe, leaking chimney pipe or flue, or cracked heat exchanger, blocked or clogged chimney opening. Improper use of appliance/device: operating a barbecue grill or vehicle in an enclosed area (like a garage or screened porch).
  • Page 6: Troubleshooting Guide

    For your records, please record: Date Purchased: _______________Where Purchased: ___________________ Date Installed: ____________/____________Month/Year First Alert ® is a registered trademark of the First Alert Trust. TROUBLESHOOTING GUIDE THIS MEANS... Low battery warning. MALFUNCTION SIGNAL. Based on its Self Test diagnostics, the unit has detected a malfunction.

This manual is also suitable for: