Download Print this page
First Alert FCD2B User Manual
First Alert FCD2B User Manual

First Alert FCD2B User Manual

120v plug-in carbon monoxide alarm with battery back-up and silence feature

Advertisement

USER'S MANUAL
120V PLUG-IN CARBON MONOXIDE ALARM WITH
BATTERY BACK-UP AND SILENCE FEATURE
~
120V AC
,
60 Hz, 0.09A
M08-0084-001 S 07/04 Printed in Mexico
IMPORTANT!
PLEASE READ CAREFULLY AND SAVE.
This user's manual contains important information about your Carbon
Monoxide (CO) Alarm's operation. If you are installing this CO Alarm for
use by others, you must leave this manual—or a copy of it—with the
end user.
TABLE OF CONTENTS
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Basic Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
How Your CO Alarm Works . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Understanding Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where to Install CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Where CO Alarms Should NOT Be Installed . . . . . . . . . . . . . . . .2
How to Install Your CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . .2
If Your CO Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If the Alarm Signal Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Using the Silence Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Weekly Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Regular Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Replacing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
What You Need To Know About CO . . . . . . . . . . . . . . . . . . . . . . . .3-4
What is CO? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Symptoms of CO Poisoning . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Finding the Source of CO After an Alarm . . . . . . . . . . . . . . . . . .3
How Can I Protect My Family? . . . . . . . . . . . . . . . . . . . . . . . . . .4
Potential Sources Of CO In The Home . . . . . . . . . . . . . . . . . . . .4
Underwriters Laboratories Inc. UL2034 . . . . . . . . . . . . . . . . . . . . . .4
General Limitations Of CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . .4
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
All Rights Reserved. © 2004 BRK Brands, Inc.
BRK Brands, Inc., 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: (800) 323-9005 • www.firstalert.com
Model FCD2BT
1
INTRODUCTION
BASIC SAFETY INFORMATION
Dangers, Warnings, and Cautions alert you to important
operating instructions or to potentially hazardous situations.
Pay special attention to these items.
THIS IS NOT A SMOKE ALARM! This CO Alarm is designed to
detect carbon monoxide from ANY source of combustion. It is
NOT designed to detect smoke, fire, or any other gas.
This CO Alarm is approved for use in single-family residences.
It is NOT designed for marine or RV use.
This CO Alarm will only indicate the presence of carbon
monoxide gas at the sensor. Carbon monoxide gas may be
present in other areas.
The Silence Feature is for your convenience only and will not
correct a CO problem. Always check your home for a potential
problem after any alarm. Failure to do so can result in injury or
death.
This CO Alarm should receive continuous 120VAC, 60 Hz, pure
sine wave electrical power. (The battery is meant for emergency
back-up only). Do not use in an extension cord or outlet con-
trolled by a dimmer or switch. In order for the emergency bat-
tery back-up to work, a working (fresh) battery must be proper-
ly installed.
NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer
to "If Your CO Alarm Sounds" for more information. Failure to
do so can result in injury or death.
Test the CO Alarm once a week. If the CO Alarm ever fails to
test correctly, have it replaced immediately! If the CO Alarm is
not working properly, it cannot alert you to a problem.
This product is intended for use in ordinary indoor locations of
family living units. It is not designed to measure CO levels in
compliance with Occupational Safety and Health Administration
(OSHA) commercial or industrial standards. Individuals with
medical conditions that may make them more sensitive to
carbon monoxide may consider using warning devices which
provide audible and visual signals for carbon monoxide concen-
trations under 30 ppm. For additional information on carbon
monoxide and your medical condition contact your physician.
HOW YOUR CO ALARM WORKS
GENERAL INFORMATION
Leave your CO Alarm plugged in year-round. CO problems can
occur any time during the year, and this Alarm can only alert you if it
is plugged in and receiving power.
This CO Alarm is intended for use in a standard, unswitched 120V AC
wall outlet. It is not intended for use in extension cords, power strips, or
outlets controlled by a switch or dimmer. These may not provide contin-
uous power to the unit. When fully powered, the unit samples the air and
takes a new reading about every second. A microchip inside the unit
stores each reading, and remembers the levels of CO it has been
exposed to over time. The Alarm sounds when it has been exposed to a
"critical" level of CO (measured in parts per million or "ppm") within a
specified time (measured in minutes). This CO Alarm features a perma-
nently installed sensor, an indicator light, and an 85dB alarm horn. It also
has a Silence Feature to temporarily quiet the alarm horn.
MALFUNCTION WARNING
This unit performs self-diagnostic tests approximately every second.
If the Alarm malfunctions, it should be replaced immediately.
THE COVER OF YOUR CO ALARM
3
1
Test/Silence Button
2
POWER/ALARM Light
(Red)
2
3
Air Vents
4
Alarm Horn: 85dB
audible alarm for test,
1
alarm, and unit
malfunction warning.

Advertisement

loading

Summary of Contents for First Alert FCD2B

  • Page 1 (fresh) battery must be proper- ly installed. • NEVER ignore your Carbon Monoxide Alarm if it alarms. Refer to “If Your CO Alarm Sounds” for more information. Failure to do so can result in injury or death.
  • Page 2: Understanding Your Co Alarm

    UNDERSTANDING YOUR CO ALARM What you see and hear during installation WHEN YOU FIRST INSTALL UNDER NORMAL CONDITIONS THE BATTERY: (AC POWER): HORN: May chirp briefly HORN: Silent POWER/ALARM LIGHT: POWER/ALARM LIGHT: Flashes once a minute Shines continuously WHEN YOU FIRST PLUG-IN WHEN YOU TEST THE CO THE CO ALARM: ALARM:...
  • Page 3: Replacing Battery

    IF YOUR CO ALARM SOUNDS Actuation of your CO Alarm indicates the presence of carbon monoxide (CO) which can kill you. In other words, when your CO Alarm sounds, you must not ignore it! IF THE ALARM SIGNAL SOUNDS: Operate the Test/Silence button. Call your emergency services, fire department or 911.
  • Page 4: Potential Sources Of Co In The Home

    A CO Alarm is an excellent means of protection. It monitors the air and sounds a loud alarm before carbon monoxide levels become threatening for average, healthy adults. A CO Alarm is not a substitute for proper maintenance of home appliances. To help prevent CO problems and reduce the risk of CO poisoning: •...
  • Page 5: Troubleshooting Guide

    If you have any questions that cannot be answered by reading this manual, call Consumer Affairs at 1-800-323-9005. BRK Brands, Inc. ("BRK") the maker of First Alert brand products, warrants that for a period of 5 years from the date of purchase, this product will be free ®...