PERFORMANCE DATA SHEETS
Base Grille Water
Filtration
System
Model WF-NL300/NL300
capacity 300 Gallons (1136 Liters)
Model WF-L500/L500
capacity 500 Gallons (1893 Liters)
@
System tested and certified by NSF International
against ANSI/NSF
Standard 53 for the reduction of Lead; and against Standard
ANS/NSF
42 for the reduct on of Taste and Odor, Ch or ne C ass ,
This system has been tested according to ANSl/NSF 42/53 for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Contaminant
Average
Influent Challenge
Product
Average %
Max. Permissible
Max.
Min. %
Reduction
Influent
Concentration
Water
Reduction
Concentration
Effluent
Reduction
mg/L
mg/L
mg/L
mg/L
Lead: @ pH 6.5
0.16
0.15 mg/L _+10%
0.0024
98.4
0.01
.005
97
Lead: @ pH 8.5
0.17
0.15 mg/L + 10%
0.0045
97.4
0.01
.009
95
Substance
Reduction
Min. Required %
reduction
Chlorine, Taste/Odor
2.0
2.0 mg/L _+10%
0.14
93.0
_>75%
N/A
N/A
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psi (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance,
and filter
replacement requirements be carried out for the product to
perform as advertised.
Using Replacement
Cartridge
NL300 - Model WF-NL300:
The concentration
of the indicated substances
in water
entering the system was reduced to a concentration
less than
or equal to the permissible limit for water leaving the system
as specified in ANSl/NSF 42 and 53. Change cartridge at
least every 6-9 months. Use replacement cartridge NL 300,
part# 4392857. 2002 suggested retail price of $29.95 U.S.A./
$39.95 Canada. Prices are subject to change without notice.
Using Replacement
Cartridge
L500 - Model WF-L500:
The concentration
of the indicated substances
in water
entering the system was reduced to a concentration
less than
or equal to the permissible limit for water leaving the system
as specified in ANSI/NSF 42 and 53. The filter monitor system
measures the amount of water that passes through the filter
and alerts you to replace the filter. When 90% of the filter's
rated life is used, the filter indicator light changes from green
to yellow. When 100% of the filter's rated life is used, the filter
indicator light changes from yellow to red, and it is
recommended
that you replace the filter. Use replacement
cartridge L500, part# 4392857. 2002 suggested retail price of
$29.95 U.S.A./S39.95 Canada. Prices are subject to change
without notice.
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or
of unknown
quality without
adequate
disinfection
before
or after the system.
Refer to the "Assistance or Service" section for parts and
service availability or for the Manufacturer's
name, address
and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Note that while the testing was performed under standard
laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with
manufacturer's
recommended
procedures and guidelines.
Application Guidelines/Water
Supply Parameters
Water Pressure
Water Temperature
33 ° - 100°F (0.6 ° - 37.8 ° C)
Rated Service Flow
0.5 gpm (1.9 Lpm)
<¢ NSF is a registered trademark