LG LP1200SDR User's Manual & Installation Instructions
LG LP1200SDR User's Manual & Installation Instructions

LG LP1200SDR User's Manual & Installation Instructions

Hide thumbs Also See for LP1200SDR:

Advertisement

Available languages

Available languages

ScUID_ _ iNsial l!_ilON i NsmUcilONS
Please retain this owner's manual for future
reference.
Read and follow all safety rules and instructions
before using this product.
To contact LG Electronics, 24 hours a day,
7 days a week:
1-800-243-0000
(US)
Or visit us on the Web at: us.lge.com
Para comunicarse con LG Electronics,
24 horas al dia, 7 dias a la semana:
1-800=243=0000
0 visitenos en la Web en: us.lge.com
AcONDlclONADOR
DEAIRE PORI! IIL
c;Ui A DEUSUAI_IO
E
INSIP, Uc€ION[S D [ INsi_! A€ION
Guarde este manual de usuario para referencia
futura. Lea y siga todas
las reglas e instrucciones
de seguridad antes
de utilizar este producto.
Model/Modelo
LP1200SDR
P/No. MFL62172001

Advertisement

Table of Contents
loading

Summary of Contents for LG LP1200SDR

  • Page 1 To contact LG Electronics, 24 hours a day, 7 days a week: 1-800-243-0000 (US) Or visit us on the Web at: us.lge.com Para comunicarse con LG Electronics, 24 horas al dia, 7 dias a la semana: 1-800=243=0000 0 visitenos en la Web en: us.lge.com...
  • Page 2: Table Of Contents

    Key Parts and Components ....Congratulations on your purchase Control Panel and Remote ....and welcome to the LG family. HOW TO USE Your new LG Air Conditioner Before Using Your Air Conditioner .... 8, 9 Using the Controls ....... 10-12 combines high=efficiency...
  • Page 3: Basic Safety Precautions

    iMPORIANI S AFELY iNSIRUcliONS READ ALL iNSTRUCTiONS BEFORE Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
  • Page 4: Electricalsafety

    llviPORlANl S AFELY INSIRUcllONS READ ALL iNSTRUCTiONS BEFORE BASic SAFETY PREcAUTiONS using this appliance, follow basic precautions, including the following: , To avoid possible cuts, avoid contacting the , To prevent spills and property damage, be sure metal parts of the air conditioner when removing to drain the air conditioner properly.
  • Page 5 RESET button. If the TEST button does not cause the circuit breaker to trip, or if the RESET button will not stay engaged, unplug the air conditioner immediately and contact your LG service technician. Due to potential safety hazards, the use of TEMPORAR...
  • Page 6: Key Parts And Components

    PARlS AND FEAlURES KEY PARTS AND COMPONENTS CONTROL PANEL AND DISPLA Y Easy=to=read white LCD display shows the operatin state. Digital touch buttons make changing settings quick and easy. MOTORIZED AIR DISCHARGE The adjustable Iouvered air discharge opens automatically when the air conditioner is turned on, and closes when it is turned off.
  • Page 7: Control Panel And Remote

    PARlS AND FEAlURES CONTROL PANEL AND REMOTE A PART B PART NOTE:Please press the _ part to operate the button. Operation of functions is the same when using the remote or the control panel, unless otherwise stated. C001 Fan Dry For detailed instructions on each function, see the following...
  • Page 8: Before Using Your Air Conditioner

    ttOW lO USE BEFORE USING YOUR AiR CONDiTiONER PREPARING FOR OPERATION UNPACKING THE AIR CONDiTiONER Refer to the Installation Instructions included Remove and store packing materials for reuse. this manual before using the air conditioner. Remove any shipping tape before using the Once the air conditioner has been properly air conditioner.
  • Page 9: Before Using Your Air Conditioner

    HOWlO USE BEFORE USING YOUR AiR CONDiTiONER /NSER TING BATTERIES/IV THE REMOTE Before using your remote, install the provided AAA batteries: Be sure to note Press and glide the battery cover on the back olarity! of the remote,then you can remove the cover. Insert two new alkaline AAA batteries into the battery compartment, being sure to note...
  • Page 10: Using The Controls

    ttOW lO USE USING THE CONTROLS Control panel buttons shoWn. Operation Always point the remote at the sensor. The using the remote control is the same, unless remote may not work if the sensor is in bright specifically noted.NOTE: The remote sensor is light or ff there is not a clear path between the remote and the sensor.
  • Page 11 ttOW lO USE USING THE CONTROLS TIMER Pressing the FAN button cycles the circulation When theTIMER function is selected, you can set the air conditioner to either automatically turn fan speed from low (F1) to medium (F2) to high (F3).The selected fan speed 7_MER up to 24 hours.
  • Page 12: Using The Controls

    ttOW lO USE USING THE CONTROLS AUTO CLEAN AUTO SW/NG To turn the AUTO CLEAN function on, press the AUTO SWING function can only be activated with AUTOCLEAN button while the air conditioner the remote. When this function is on, the air discharge will oscillate to Auto c_+_...
  • Page 13: Preparing For Installation

    iNslallaliON iNSIRUcliONS PREPARING FOR INSTALLATION WABU|U , WWI,_FI|I The air conditioner is heavy! Use two or more people lift and install the unit! Failure to do so could result in back injury or other injuries. EXHA US T C OV/P OIVEN TS The following components are used for window venting.
  • Page 14: Attachingthe Hose And Diffuser

    iNSlAilaliON iNSIRUcliONS ATTACHINGTHE HOSE AND DIFFUSER NOTE: The air conditioner is shipped With the hose instafled. The hose may be removed for cleaning and storage, if necessary. Simply reverse the steps below to remove. As you see from Fig,insert this end of the hose into the hole on the back of the air conditioner.
  • Page 15: Window Vent Panel And Extensions

    iNslali_aliONiNSIRUcliONS WINDOW VENT PANEL AND EXTENSIONS The window installation kit allows you to install the air conditioner in most vertical-sliding windows 18" to 48" wide, or casement-style windows from 18" to 48"high. Small extension panel Small - extension panel For window openings from 18¼" to 24", For an 18"...
  • Page 16: Installationin Vertical Sliding Windows

    iNslAilaliON iNslRUcliONs iNSTALLATiONiN VERTICAL SLiDiNG WINDOWS NOTE: The WindoW installation kit can be used with vertical sliding windows between 18" and 48" wide. Foam seal C type-shorter) Extension panel _L(_required) T-------_ v_____ent < (Adhesive type) Cut the foam seal A(adhesive type) & Insert the vent panel assembly, including C(adhesive type-shorter)to the proper...
  • Page 17: Installation In Vertical Sliding Windows

    iNslallaliON iNSIRUcliONS iNSTALLATiONIN VERTICAL SLiDiNG WINDOWS Security Bracket Type A screw Insert the oval end of the diffuser into the Install the security bracket with a type A window installation kit until the locking tabs screw, as shown. engage.
  • Page 18: Installation In Casement Windows

    iNslAilaliON iNslRUcliONs iNSTALLATiONiN cASEMENT STYLE WINDOWS NOTE: The window installation kit can be used with casement windows between 18" and 48" tall.._,,% Foam seal C (Adhesive type-shorter) Foam seal (Adhesive type) Cut the foam seal A(adhesive type) & Insert the vent panel assembly, including C(adhesive type-shorter)to the proper...
  • Page 19 iNslallaliON iNSIRUcliONS iNSTALLATiONiN cASEMENT STYLE WINDOWS Security bracket Type A screw Insert the oval end of the diffuser into the install the window security bracket with a window installation kit until the locking tabs type A screw, as shown. engage.
  • Page 20: Care And Cleaning

    For maximum efficiency, it is recommended operation with only minimal cleaning and that you have the cooling coils inspected maintenance. cleaned annually. Your local LG Authorized Service Center can provide this inspection and cleaning service for a nominal fee. WARNING • Unplug...
  • Page 21: Emptying The Water:collectiontank

    CAREAND€iEANiNc EMPTYING THE WATER:COLLECTIONTANK Using the bottom drain port When the internal water collection tank is full, FL will appear in the display and the air conditioner will turn off until the tank is emptied. Unplug the air conditioner, disconnect the exhaust hose from the back, and move the air conditioner to a suitable drain...
  • Page 22: Storing The Air Conditioner

    CAREAND€iEANiNc STORING THE AiR cONDiTiONER If the air conditioner will not be used for an Before using the air conditioner again: extended period of time: Make sure the filter and drain cap are in place. Drain the water collection tank completely and leave the bottom drain cap and rubber Check the cord to make sure it is in good plug long enough to allow any residual water...
  • Page 23: Before Callingfor Service

    IROUB[ESttOOIiNc BEFORE CALLINGFOR SERviCE Before you call for service, review this list. It may save you time and expense. This list includes common occurrences that are not the result of a defect in workmanship or materials......i............................... ;............... Make sure e ectrica p ug isp ugged completely...
  • Page 24 IROU iESttOOllNG BEFORE CALMNG FOR SERVICE Problem Possible Causes Solutions Codeappears in the display: • Airconditioner isin FANmode F1,F2,or F3 • Thisis normal. T heair conditioner isworking properly. andthe numbershownis theset fanspeed. • Thewatercollectiontankisfull. Emptythewatercollection tank.Seethe CareandCleaning section. CH01 Shortor opencircuitin the indoor Unplug theair conditioner andcontact y ourauthorized air thermostat.
  • Page 25: Productregistration Information

    Should your LG PortableAir Conditioner prove to be defective in material or workmanship under normal use duringthe warranty period listed below, effective from the date of original consumer purchase of the product, LG Electronicswill replacethe defective part(s). Replacementparts will meet intended fit and function of the original part.
  • Page 26 Piezas y componentes clave ....Felicitaciones por su compra Panel de control y control remoto ..... bienvenido a la familia de LG. COMO UTILIZAR EL ARTEFACTO Antes de utitizar su acondicionador de aire ... 32, 33 Su nuevo acondicionador de aire C6mo usar los controles ....
  • Page 27 IMPOfilANIES INSIfiUcclONES DE SECURIDAD I-SA TODAS I-AS |NSTRUCC|ONSS ANTES DS USAR Su seguridad y ia seguridad de otros son muy importantes. Hemos incluido muchos mensajes de segufidad importantes en este manual y en su artefacto. Siempre lea y obedezca todos los mensajes de seguridad.
  • Page 28 llviPOfilANIES INSIfiUcclONES DE SEGURIDAD M=A TODAS LAS |NSTRUCC|ONSS ANTSS DS USAR PRECAUCIONES BASICAS DE SEGURIDAD PRECAUC|ON dosco,.go o, c .co o lesiones a personas cuando utilice este artefacto, deben seguirse precauciones b_sicas seguridad, incluyendo las siguientes: * Para evitar posibles cortes, evite el contacto con las * Para evitar derrames y dafios a la propiedad, asegOrese de drenar el acondicionador de aire correctamente.
  • Page 29 RESET (reconfiguraci6n) no queda trabado, desenchufe ,fi_ el acondicionador de aire de inmediato y ..,.17... >117 ..comuniquese con un tecnico de LG. Debido a peligros de segurid ad potenciales, METODO DE CONEXION A TIERRA "%...
  • Page 30 PIEZASY €ARAclERiSllcAS PARTES Y comPONENTES PRINCIPALES PANEL DE CONTROL YPANTALLA La pantalla LCD de facil lectura muestra el estado de funcionamiento. Los botones tactiles digitales permiten cambiar la configuraci6n de forma rapida y sencilla. DESCARGA DE AIRE /ViO TORIZADA La rejilla ajustable de descarga de aire se abre automaticamente cuando el equipo se enciende y se cierra cuando se apaga el equipo.
  • Page 31 PIEZASY €ARAclERTSllcAS PANEL DE CONTROL Y CONTROL REmOTO A PART B PART NOTA: Pulse la parte para utiNzar el bot6n. En caso de no indicar Io contrario, la operaci6n de las funciones Co01 Fan Dry es la misma al usar el control remoto y el panel de control. ?im_ r ..dill Para obtener una informaci6n...
  • Page 32 cOMOUliiiZaR Ei ARIEFACIO ANTES DE UTILIZAR EL ACONDICIONADOR DE AIRE PREPARACION PARA LA OPERACION COMO DESEMPACAR ACONDICIONADOR DE AIRE Lea las Instrucciones de instalaci6n incluidas en Quite y guarde los materiales de empaque para este manual antes de usar el acondicionador volverlos a usar.
  • Page 33 cOMOUliiiZaR Ei ARIEFACIO ANTES DE USAR EL AIRE ACONDICIONADO INSERC/ON DE/_AS BA TERiAS EN EL CONTROL REMOTO Antes de usar el control remoto, instale las baterias AAA proporcionadas: iAsegOrese de tener en Apriete deslice la cubierta de baterias del control ridad! remoto y, a continuaci6n, retire la cubierta.
  • Page 34 cONOUliliZaR [i ARIEFACIO UTILIZACION DE LOS CONTROLES Se muestran los botones del panel de control. Apunte siempre el control remoto hacia el sensor. La operaci6n usando el control remoto es la El control remoto podria no funcionar si el sensor misma, a menos que se especifique Io contrario.
  • Page 35 ¢OMOU[iliZaR ei ARIEFACIO UTILIZACiON DE LOS CONTROLES VEL OCIDAD DE VENTILADOR TEMPORIZADOR Cuando se selecciona la funci6n TIMER Pulsar el bot6n FAN SPEED (VELOCIDAD VENTILADOR) iniciara un ciclo de velocidad de (TEMPORIZADOR) puede configurar el aire ventilador entre baja (F1) a media TIMER apagarse automaticamente...
  • Page 36 cOMOUliliZafi Ei ARIEFACIO UTILIZACION DE LOS CONTROLES Para cancelar la funci6n AUTO CLEAN A U TOL IMPIEZA (AUTOLIMPIEZA), o para detener el ciclo de Para activar la funciGn AUTO CLEAN autolimpieza, simplemente pulse de nuevo el bot6n (AUTOLIMPIEZA), pulse el botGn AUTO CLEAN AUTO CLEAN (AUTOLIMPIEZA).
  • Page 37 MFL36812504_SP:Layollt 2007.12.8 1:43 Page INSI UCCI(NES DE INS LAGON PREP AIRACION PARA LA INSTALACION AD VER TEN CIA iEl_condicionadordo_dleospos_do! iUtJlico o mOs personas pttrtt lewtntttr o inst_tlttrlttunidttd!No h_tcorlo puodo provocttr le_ionos on lttosp_tldtt u otrtts les ionos. COMPO _\_ N TES DE SALIDA siguie_tes compo nentesse...
  • Page 38 iNslalaciON iNSIRUcciONES DE COMO CONECTAR LA MANGUERA Y EL DIFUSOR NOTA: El aire acondicionado se envia con la manguera instalada, Si es necesario, puede retirarla para limpieza y almacenamiento, Para retirarla simplemente siga los pasos anteriores en sentido inverso, Como puede ver en la figura, inserte el extremo de la manguera en el orificio de la parte trasera del aire acondicionado.
  • Page 39 iNslaiaciON iNSIRUcciONES DE PANEL DE VENTILACION Y EXTENSIONES DE LA VENTANA El equipo de instalacidn le permite instalar el acondicionador de aire en la mayoffa de las ventanas de desfizamiento vertical de 18 " a 48" de ancho, o ventanas deslizamiento horizontal de 18 "...
  • Page 40 iNslalaciON iNSIRUcciONES DE INSTALACION EN VENTANAS DE DESLIZAMIENTO VERTICAL NOTA: El equipo de instalaci6n en ventanas puede utilizarse con ventanas de deslizamiento vertical de un ancho de entre 18" y 48". Tipo C de sellado con espuma (tipo adhesivo-mas corto). Sellante de espuma A adhesivo) ..
  • Page 41 iNslaiaciON iNSIRUcciONES DE INSTALACION EN VENTANAS DE DESLIZAMIENTO VERTICAL Sopo_e de seguridad Tornillos Tipo A Introduzca el extremo oval del difusor dentro Instale el soporte de seguridad con un tornillo tipo A, como puede verse. del equipo de instalaci6n en ventanas hasta que las lengOetas queden trabadas.
  • Page 42 iNslalaciON iNSIRUcciONES DE INSTALACION EN VENTANAS DE DESLIZAMIENTO HORIZONTAL NOTA: El equipo de instalaci6n de ventanas puede usarse con ventanas con bisagras con una altura de 18"a 48". Sellado con espuma C (tipo adhesivo- as corto) Sellado con espuma A Panel de ventilaci6n Corte la espuma A (tipo adhesivo) y C (tipo...
  • Page 43 iNslaiaciON iNSIRUcciONES DE INSTALACION EN VENTANAS DE DESLIZAMIENTO HORIZONTAL Soporte de seguridad Tornillos Tipo A ....................Instale el soporte de seguridad con un Introduzca el extremo oval del difusor tornillo tipo A, como puede verse. dentro del equipo de instalaci6n en ventanas hasta que las lengQetas queden trabadas.
  • Page 44 Iimpiar las serpentinas fimpieza y mantenimiento mfnimos. enfriamiento una vez por ado. Su Centro de Servicio Autorizado LG local puede prestar este servicio de inspeccidn y fimpieza por una mddica suma. ADVERTENCIA • Desenchufe el acondicionador de aire antes...
  • Page 45 €UiDADO¥ [iMPiEZA RECOLECCION COIViOVAClAR EL TANOUE DE DE AGUA Empleando el puerto inferior de drenaje Cuando el tanque interno de recolecci6n de agua est_ Ileno, aparecer& FL en la pantalla y el acondicionador de aire se apagar_ hasta que se vacie el tanque.
  • Page 46 €UiDADO¥ iiMPIEZA COMO GUARDAR EL ACONDICIONADOR DE AIRE Si no va a usar el acondicionador de aire durante Antes de volver a usar el acondicionador de aire: un perfodo prolongado: Gb Verifique que el filtro y la tapa de drenaje esten en su lugar.
  • Page 47 DEiECCION DE PROB[EMAS ANTES DE LLAMAR AL SERVlClO Ti CNICO Antes de Ilamar al servicio tecnico, examine esta list& Puede ahorrarle tiempo y dinero. La [ista incluye situaciones comunes que no son el resultado de mano de obra o materiales defectuosos del artefacto.
  • Page 48 • Hay un circuito cortado o abierto en el • Desenchufe el aire acondicionado y p6ngase en termostato del aire de interior, contacto con un servicio tecnico LG autorizado. CH02 • Hay un circuito cortado o abierto en el • Desenchufe el aire acondicionado...
  • Page 49 1. Visitasa su domicilio paraentregar o retirarpiezas, i nstalar, i nstruir, reparacionesinadecuadasincluyen el uso de piezas no aprobadas reemplazar fusiblesdom6sticos, conexi6n de cableados o caSerias, o o especificadaspor LG. paracorregirreparaciones n oautorizadas. 10. Mantenimientonormal como se describe el la Guiade Usuario,como 2.
  • Page 50 NOIES...
  • Page 51 NOIES...
  • Page 52 P/No. MF162172001 Printed in China...

Table of Contents