Extron electronics SCP 150 AAP User Manual
Extron electronics SCP 150 AAP User Manual

Extron electronics SCP 150 AAP User Manual

Relay control modules control accessories
Hide thumbs Also See for SCP 150 AAP:

Advertisement

Quick Links

Extron Electronics, USA
Extron Electronics, Europe
1230 South Lewis Street
Beeldschermweg 6C
Anaheim, CA 92805
3821 AH Amersfoort
USA
The Netherlands
714.491.1500
+31.33.453.4040
www.extron.com
Fax 714.491.1517
Fax +31.33.453.4050
© 2002 Extron Electronics. All rights reserved.
Extron Electronics, Asia
Extron Electronics, Japan
135 Joo Seng Road, #04-01
Daisan DMJ Building 6F
PM Industrial Building
3-9-1 Kudan Minami
Singapore 368363
Chiyoda-ku, Tokyo 102-0074 Japan
+65.6383.4400
+81.3.3511.7655
Fax +65.6383.4664
Fax +81.3.3511.7656
User's Manual

Relay Control Modules

SCREEN POSITION
DOWN
STOP
UP
RCM-SC
ROOM CONTROL
SCREEN POSITION
LIGHTING
ON / OFF
RCM-SCLT
Control Accessories
68-631-01
Printed in the USA

Advertisement

Table of Contents
loading

Summary of Contents for Extron electronics SCP 150 AAP

  • Page 1: Relay Control Modules

    Extron Electronics, USA Extron Electronics, Europe Extron Electronics, Asia 1230 South Lewis Street Beeldschermweg 6C 135 Joo Seng Road, #04-01 Anaheim, CA 92805 3821 AH Amersfoort PM Industrial Building Singapore 368363 The Netherlands 714.491.1500 +31.33.453.4040 +65.6383.4400 www.extron.com Fax 714.491.1517 Fax +31.33.453.4050 Fax +65.6383.4664 ©...
  • Page 2: Fcc Class A Notice

    Precautions Safety Instructions • English Warning This symbol is intended to alert the user of important Power sources • This equipment should be operated only from the power source indicated on the product. This equipment is intended to be used with a main operating and maintenance (servicing) instructions power system with a grounded (neutral) conductor.
  • Page 3: Table Of Contents

    Table of Contents Chapter 1 • Introduction ... 1-1 About the Relay Control Modules Features ... 1-2 Chapter 2 • Installation and Operation Installation Overview ... 2-2 UL Requirements ... 2-3 Rear Panel Connectors and Switches Cabling ... 2-5 MLC relay wiring for an RCM-SC ... 2-8 MLC relay wiring for an RCM-SCLT ...
  • Page 4: Chapter 1 • Introduction

    Table of Contents, cont’d Relay Control Modules Chapter One Introduction About the Relay Control Modules Features Relay Control Modules • Table of Contents...
  • Page 5: About The Relay Control Modules

    Introduction About the Relay Control Modules The Extron Relay Control Modules (RCMs) are hard-wired remote control keypads designed for use with the Extron MediaLink Controller (MLC). Refer to the MediaLink Controllers User’s Manual for information on installing, operating, and setting up the controller. All setup must be done via RS-232.
  • Page 6: Installation Overview

    Installation and Operation Installation Overview Installation and service must be performed by CAUTION authorized personnel only. These products should be used with UL approved electrical boxes. See “UL Requirements”, page 2-3. To install and set up Relay Control Modules, follow these steps: Turn the equipment off.
  • Page 7: Rear Panel Connectors And Switches

    Installation and Operation, cont’d Rear Panel Connectors and Switches The same type and quantity of connectors and DIP switches shown above can be found on the rear panels of all models of the control modules. Communications connectors — Use these connectors to connect control modules together and to connect them to the MLC and to an optional IR Link infrared repeater.
  • Page 8 Installation and Operation, cont’d Control Module +12VDC Ground ( ) Control signal (RCM/ IRCM) IR / RCM port A B C D IR / RCM MLC 206 to a daisy chain of Control Modules Connectors are included with each control module, but the cable must be purchased separately.
  • Page 9: Mlc Relay Wiring For An Rcm-Sc

    Installation and Operation, cont’d MLC relay wiring for an RCM-SC Low Voltage Controller SCREEN POSITION DISPLAY DOWN STOP POWER Laptop VOLUME UNSWITCHED MAX/ RCM-SC 100-240V - 5AMAX Extron MLC 206 MediaLink Controller MLC 206 w/ AAP A typical RCM-SC application The diagrams included here are examples only.
  • Page 10 Installation and Operation, cont’d The diagrams included here are examples only. Your equipment may have different wiring requirements. Refer to the specific wiring instructions provided by the manufacturer of the screen controller and AC power controller that you are using. Low Voltage Controller (Da Lite/Draper) Up (Stewart)
  • Page 11: Front Panel Features And Operation

    Installation and Operation, cont’d 120 VAC 50/60 Hz MAX LOAD 15 A LISTED 7Z37 PROFESSIONAL AUDIO EQUIPMENT MINIPORT-15 POWER RELAY CLASS2 WIRING +12VDC 6Ma MAX STATUS MLC Relay Port Connecting a Furman MiniPort-15 AC power controller to the MLC for lighting control For the Furman controller, connect pins 3A and 3B of the MLC’s relay port to the 12VDC and REM poles.
  • Page 12: Testing/Troubleshooting

    Installation and Operation, cont’d In the Relay & Misc. Options portion of the control program, select the appropriate options for each relay. For example, set the relays that are tied to the Screen Position Up ( ), Screen Position Down ( ), and Stop buttons to Momentary, and select the duration for the momentary contact.
  • Page 13: Mounting The Control Module Into An Aap Wallplate Or Device Faceplate

    Installation and Operation, cont’d All IR control signals are sent to all devices (video sources, projector, etc.) at the same time even if two or three IR Emitters or an IR Broadcaster are installed. The IR sending devices share the same IR Display/Control port on the MLC.
  • Page 14: Part Numbers

    Specifications, Part #s, Accessories, Dimensions Specifications General Power ... 12VDC from the MLC 206 Temperature/humidity ... Storage -40° to +158°F (-40° to +70°C) / 10% to 90%, non-condensing Operating +32° to +122°F (0° to +50°C) / 10% to 90%, non-condensing Rack mount ...
  • Page 15: Dimensions

    Specifications, Part Numbers, Accessories, cont’d Dimensions The following diagrams have been reduced to fit on the page. All dimensions are given in inches. The symbol “ø“ indicates a diameter. RCM dimensions +.000/ Ø.160 max. extrusion around -.010 stud on far side, +.003/ Ø.112 thru (4 places ).

This manual is also suitable for:

Rcm-scRcm-sclt

Table of Contents