Briggs & Stratton Portable Generator Operator's Manual

Hide thumbs Also See for Portable Generator:
Table of Contents

Advertisement

Available languages

Available languages

IGGS & STRA_O
®
I
G
rator's
I
This generator is rated in accordance with CSA(Canadian Standards
Association) standard C22.2 No. 100-04 (motors and generators).
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, W ISCONSIN,U.S.A.
Manual No. 206883GS
Revision A (09/03/2008)

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Briggs & Stratton Portable Generator

  • Page 1 IGGS & STRA_O ® rator's This generator is rated in accordance with CSA(Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators). BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC JEFFERSON, W ISCONSIN,U.S.A. Manual No. 206883GS Revision A (09/03/2008)
  • Page 2 Thankyou for purchasing this quality-built Briggs & Stratton generator. We are pleasedthat you've placed your confidence in the Bfiggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Bfiggs & Stratton generator will provide many years of dependable service. This manual containssafety information to make you aware of the hazards and risks associated with generators and how to avoid them.
  • Page 3: Table Of Contents

    Table of Contents €1# OperatorSafety ......... Equipment Description......... important Safety information ........Assembly ........Unpack Generator ..........Install Wheel Kit..........Verify Engine Oil Level......... Add Fuel............ System Ground ..........Connecting to a Building's Electrical System......Generator Location ........... Features and Controls ......Cord Sets and Receptacles ........
  • Page 4: Operatorsafety

    Operator Safety important Safety information The manufacturer cannot possibly anticipate every possible EquipmentDescription circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work Read this manual carefully and becomefamiliar with your generator.
  • Page 5 A, WARNING: Generator produces hazardous voltage. bJl|m Failure to isolate generator from power utility €ID can result in death or injury to electric utility Using a generator indoors CAN KiLL YOU iN MINUTES, workers due to backfeed of electrical energy. Generator exhaust contains carbon monoxide, This is •...
  • Page 6 A, WARNING: Contact with muffler area can result in A, CAUTION: Excessively high operating speeds increase serious burns. risk of injury and damage to generator. Exhaust heat/gases can ignite Excessively low speeds impose a heavy load. combustibles, structures or damage •...
  • Page 7: Assembly

    Install the wheel kit as follows: Assembly 1. Tip generator so that engine end is up. F_[-_-_IBead entire operator's manual beforeyou attempt 2. Slide axle (A) through both mounting brackets. to assemble or operate your new generator. 3. Slide a wheel (B) over axle. Your generator requires some assembly and is ready for use NOTE:Be sure to install wheel with raised hub inboard.
  • Page 8: Verify Engineoil Level

    Verify EngineOil Level A. WARNING: Fueland its vapors are extremely The generator engine is shipped from the factory filled with flammable and explosive. oil (API SJ or higher 10W-30). This allows for generator Fire or explosion can cause severe burns or death. operation in the widest range of temperature and climate WHEN ADDINGFUEL conditions.
  • Page 9: System Ground

    GeneratorLocation System Ground The generator has a system ground that connects the Clearances and Air Movement generator frame components to the ground terminals on the A, WARNING: Exhaustheat/gases can ignite AC output receptacles.The system ground is connected to combustibles, structures or damagefuel tank the AC neutral wire (the neutral is bonded to the generator causing a fire.
  • Page 10: Features And Controls

    Features and Controls Read this Operator's Manual and safety rules before operating yourgenerator. Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference. K - Identification Label -- Provides model, revision and A - Fuel Tank -- Capacity of seven (7) U.S.
  • Page 11: Cordsets And Receptacles

    120 Volt AC, 20 Amp, Duplex Receptacles CordSets and Receptacles The duplex receptacles are protected against overload by a Use only high quality, well-insulated, grounded extension cords with the generator's 120 Volt duplex receptacle. two pole rocker switch circuit breaker. Inspect extension cords before each use.
  • Page 12: Operation

    Operation 5. Grasp recoil handle and pull slowly until slight resistance is felt. Then pull rapidly one time only to start engine. Starting the Engine A. WARNING:Starter cord kickback (rapid retraction) can Disconnect all electrical loads from the generator. Use the result in bodily injury.
  • Page 13: Connecting Electricalloads

    Connecting ElectricalLoads Stopping the Engine 1. Let engine stabilize and warm up for a few minutes 1. Turn OFFand unplug alJ electrical loads from generator after starting. panel receptacles. NEVERstart or stop engine with electrical devices plugged in and turned ON. 2.
  • Page 14: Don't Overloadgenerator

    Don't OverloadGenerator NEVERadd more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as Capacity described above. You must make sure your generator can supply enough Rated* Additional rated (running) and surge (starting) watts for the items you Toolor Appliance (Running) Surge (Starting)
  • Page 15: Maintenance

    Maintenance Emissions Control Maintenance, replacement, or repair of the emissions controldevices and systemsmay be performed by any Maintenance Schedule non-roadengine repair establishment or individual. Follow the hourly or calendar intervals, whichever occurs However,to obtain "no charge" emissions control service, first. More frequent service is required when operating in the work must be performed by a factory authorized dealer.
  • Page 16: Enginemaintenance

    Adding Engine Oil EngineMaintenance 1. Make sure generator is on a level surface. _. WARNING: Unintentional sparking can result in fire or 2. Check oil level as described in Checking Oil Level electric shock. 3. if needed,slowly pour oil into oil fill opening to the point of overflowing at oil fill.
  • Page 17 Service A irCleaner Inspect IVluffierand Spark Attester Your e ngine willnotrunproperly and may bedamaged if inspect the muffler for cracks, corrosion, or other damage. yourunitwitha dirty aircleaner. Replace more often if Remove the spark arrester, if equipped, and inspect for operating under d irty ordusty conditions.
  • Page 18 Clean Cooling S ystem Check Valve Clearance Over t ime debris m ay accumulate incylinder cooling f insand Regular valve clearance check and adjustment will improve cannot beobserved without partial engine d isassembly. performance and extend engine life. This procedure cannot thisreason, werecommend youhave anauthorized service be done without partial engine disassembly and the use of...
  • Page 19: Storage

    Change Engine Oil Storage While engine is still warm, drain oil from crankcase. Refill The generator should be started at least once every seven with recommended grade. See Changing Engine OiL days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use Other Storage Tips: the following guidelines to prepare it for storage.
  • Page 20: Troubleshooting

    Troubleshooting Problem Correction Cause 1. Reset circuit breaker. 1. One of the circuit breakers is open. 2. Fault in generator. 2. Contact authorized service facility. Engine is running, but no AC 3. Poor connection or defective cord set. 3. Checkand repair. output is avaiiabJe.
  • Page 21: Warranties

    Warranties As the small off-road engine owner, you should however be aware that B&S may deny you warranty coverage if your small off-road engine or a part has failed due to abuse, Emissions Control System Warranty neglect, improper maintenanceor unapproved modifications. Briggs &...
  • Page 22 2. Length o fCoverage Emission Information B&S warrants totheinitial o wner and each subsequent Engines that are certified to meet the California Air purchaser thattheWarranted Parts s hall b efree from Resources Board (CARB) Emission Standards must display defects inmaterials and workmanship which caused the information regarding the Emissions Durability Period and failure o fthe Warranted Parts f oraperiod oftwoyears...
  • Page 23 Effective February 1,2006 replaces all undated Warranties and all Warranties dated before February 1,2006 LiMiTED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or workmanship or both.
  • Page 24: Product Specifications

    ® Portable enerator Product Specifications Starting Wattage ......8,250 watts Wattage ......5,500 watts AC Load Current: at 120 Volts ......45.8 Amps at 240 Volts ......22.9 Amps Phase ....... Single phase Rated Frequency ......60 Hertz Displacement ...... 18.61 ci (305 cc) Spark Plug Gap ....
  • Page 25 IGGS & STRA_O ® Este generador est_ clasificado conforme a la norma C22.2 No. 100-04 (motores y generadores) de la CSA (Canadian Standards Association [Asociaci6n canadiense de normalizaci6n]). BRIGGS& STRATTON POWERPRODUCTS GROUP,LLC JEFFERSON, W ISCONSIN,U.S.A.
  • Page 26 iVluchas gracias per comprar este generador Briggs & Stratton de gran calidad. Nos alegra que haya depositado su confianza en la marca Briggs & Stratton. Siempre que sea utilizado de acuerdo con las instrucciones de este manual, su generador Briggs & Stratton le proporcionar_ muchos a_os de buen funcionamiento. Este manual centiene informaci6n sobre seguridad para hacerleconsciente de los riesgos asociados a los generadores y mostrarle c6mo evitarlos.
  • Page 27 Tablade Contenido Seguridad de operario ......Descripci6n del equipo ........InformaciOn importante de seguridad ......Montaje ........Desembalajedel generador ........Instale el juego de ruedas ........Comprobar el nivel de aceite del motor ......Agregue combustible .......... Tierra del sistema ..........ConexiOnal sistema el6ctrico de un edificio ......
  • Page 28: Seguridadde Operario

    Seguridadde operario Sirnbolos sobre la seguridady significados Descripci6ndel equipo Lea alenlarnenle esle manual y farniliaricese con Descarga El_ctrica Gases T6xicos Contragolpe el generador. Conozcasus aplicaciones, lirnitacionesy riesgos. Este generador funciona en base a un motor de campo ei6ctrico giratorio y de corriente alterna (CA). Fuedise_ado con ia finalidad de proveer energia el6ctrica para i_mparas Explosi6n Manual d el Operario...
  • Page 29 A. ADVERTENCIA: La gasolina y sus vapores son "-] extremadamente inflamables y El uso de un generador en un espacio interior PUEDE explosivos. PROVOCAR LA MUERTE EN POCOS MINUTOS. El fuego o una explosi6n pueden causar quemaduras severase inclusive la muerte. Los gases de escape del generador contienen CUAND0 ANADA COMBUSTIBLE 0 VACiE ELDEP6SIT0 mon6xido de carbono, un veneno invisible e inodoro.
  • Page 30 A, ADVERTENCIA: El contacto con la zona del silenciador A, PRECAUCION: L as velocidades de operaci6n en puede producir quemaduras graves. exceso, aumentan los riesgos de heridasy da_os al generador. ,_>,_,,_ _ Los gases y ei calor de escape pueden infiamar los materiales combustibles y Lasvelocidades bajan en exceso, imponen una carga muy las estructuras 0 da_ar el dep6sito de combustible y...
  • Page 31: Montaje

    • ANcates IVlontaje • Gafas de seguridad Su generador requiere de ciertos procedimientos de montaje y Siga estos pasos para inslalar el juego de ruedas: solo estar_ listo para set utilizado despu6s de haberle suministrado servicio con el combustible y aceite 1.
  • Page 32: Comprobarel Nivel De Aceite Del Motor

    13. Vuelvaa colocar el generador en la posici6n normal de _i, AI:IVERTENCIA: La gasolina y sus vapores son funcionamiento (apoyadoen las ruedasy la pata de extremadamente inflamables y apoyo). explosivos. NOTA:Gire el asa en el bastidor del generador s61ocon fines El fuego o una explosi6n pueden causar de almacenamiento.
  • Page 33: Tierra Del Sistema

    Tierra del sislema Ubicaci6ndel generad0r El generador dispone de una conexi6n a tierra del sistema Espaci0 Libre Alreded0r del Generad0r que conecta los componentes del bastidor a los terminales de tierra de los enchufes hembra de salida de CA. La tierra Ak ADVERTENCIA: Los gases y el caior de escape pueden del sistema est_ conectada al cable de CA neutro que, a su inflamar los materiales combustibles y las...
  • Page 34: Controles Y Caracteristicas

    Controles y caracteristicas Lea este Manual del 0perario y reolas de seouridadantes de porter en marcba su generador. Compare las ilustraciones con su generador, para familiarizarse con la ubicaci0n de los diversos controles y ajustes. Guardeeste manual para futuras consultas. A =Tanque del Combustible -- El tanque tiene una K - Etiquetade IdentificaciOn -- Proporciona el modelo, capacidad de 7 galones americanos de gasolina sin...
  • Page 35: Juego De Cables Del Adaptador Del Generador

    Jueoosde cordones y enchulesconeclores AV/SI_, Las tomas el6ctricas pueden marcar un valor nominal mayor que la capacidad de salida del generador. Utilice exclusivamente cables prolongadores de alta calidad, . NUNCAintente conectar un dispositivo que requiera m6,s bien aislados y con conexi6n a tierra para la toma doble de amperaje dei que el generador o la toma el_ctrica pueden 120 V del generador.
  • Page 36: Operando

    Operando 6. Mueva la palanca de choque hasta la posici6n "Half" (media) y accione dos veces la manija de retroceso. Si ei motor no arranca, repita los pasos desde Enciendael molor 5 hasta 7. Desconectetodas las cargas el6ctricasdel generador. Use las 7.
  • Page 37: Conexionde Cargas El6Ctricas

    Parada del motor Conexi6n de cargasel6clricas 1. Deje que el motor se estabiNcey se caNentepor dos 1. Desconectetodas las cargas el6ctricas de los minutos despu6s del arranque. tomacorrientes del panei del generador. Nunca de arranque o detenga el motor con todos los dispositivos 2.
  • Page 38: No Sobrecargarel Generador

    6. Repita los pasos 4 y 5 para cada carga adicional que No sobrecargarel generador usted tenga. Capacidad NUNCAa_ada cargas que sobrepasen la capacidad del Debe asegurarse de que su generador puede proveer los generador. Tenga especial cuidado en contar con las cargas suficientes vatios de potencia continua (vatiaje nominal) y adicionales en la capacidad del generador, come se describe vatios de saNdapara los eiementos que deseeaNmentaral...
  • Page 39: Ivlantenimiento

    IVlantenimiento Control de emisiones Cualquier estahlecimientoo individuoespecializadoen la reparaci6n de rnotoresque no sean de autornoci6n puede Plan de mantenimiento encargarsedel rnantenirniento,la sustituci6ny la Siga los intervalos de horas o de calendafio, los que sucedan reparaciOn de los dispositivos y sisternasde control de antes.
  • Page 40 iVlanlenimienlo del molor Comprobaci6n del nivel de aceite Compruebe el nivel de aceite antes de cada uso o cada _, ADVERTENCiA: C hispear involuntario puede tener 8 horas de funcionamiento, como minimo. Rellenesi es ',, d=. como resultado el fuego o el golpe necesario.
  • Page 41 Limpie la zona de alrededor del tap6n de vaciado de Servieio del bujia aceite (A), situado en la base del motor, al otto lado del Cambie la bujia ayudar_ a su motor a arrancar m_s carburador. f_cilmente y funcionar mejor. 1.
  • Page 42 Lirnpie e inspeccioneel apaoachispasde la siouienle Comprobaci6n de holgurade la v_lvula m398r3: Si comprueba y ajusta la holgura de la v_lvula regularmente, 1. Para retirar la protecci6n del silenciador (A) de el funcionamiento del motor mejorar_ y tendr_ una mayor silenciador (B), retire los cuatro tornillos que conectan vida 0til.
  • Page 43 Almacenarniento Si no se ha a_adido un estabilizador de combustible a la gasoiina, deber_ vaciar completamente el motor utiiizando El oenerador deber_ ser encendido al menos una vez cada un contenedor homoiogado. Dejefuncionar el motor hasta siete dias y deber_ dejaflo funcionar al menos durante que se agote el combustible.
  • Page 44: Resoluci6N De Probiemas

    Resoluci6n de problemas Problemo CaUS3 Action 1. El interruptor autom_tico de 1. Reposicioneel interruptor. circuito est_ abierto. 2. Conexi6n mal o defectuosa del EI motor est_ funcionando 2. Revisey repare. juego de cables. pero no existe salida de AC disponsibie. 3.
  • Page 45: Garantiadel Sistema De Control De Emisiones

    Garanlias Como propietario del peque_o motor para m_quinas de servicio, debe ser consciente de que B&S puede denegar la cobertura de la garantia si el motor o uno de sus Garantia del sistemade controlde ernisiones componentes falla debido a un uso indebido o negligente, un mantenimiento inadecuadoo modificaciones no autorizadas.
  • Page 46 e. Elementos diversos utilizados en los sistemas Informaci6n sobreemisiones anteriores Los motores con certificaci0n de cumplimiento de la • V_lvulas y conmutadores de aspiraciOn, normativa sobre emisiones del California Air Resources temperatura, posiciOn y temporizados Board (CARB) deben mostrar informaci0n sobre el periodo de durabilidad de ias emisiones y el indice de aire.
  • Page 47 Fechadeentradaen vigor:l de Febrero de 2006.Sustituye a todaslasgarantias sinfechay a lasde fechaanterioral1 Febrero de 2006 GARANTiA LllVIITADA Briggs & Stratton Power Products Group, LLC reparar_ o sustituir_ sin cargo alguno cualquier componente del generador port_til que presente defectos de materiales y/o mano de obra. Los gastos de transporte de las producto enviadas para reparar o sustituir conforme a los t_rminos de esta garantia correr_n a cargo del comprador.
  • Page 48: Especificaciones Del Producto

    BRIGGS&STRA ® nora or port til Especificaciones d ei producto Vataje que Empieza ....8,250 Vatios (8,25 kW) Vataje ......5,500 vatios (5,5 kW) Carga Corfiente de C.A. a 120 Voltios ......45.8 Amperios a 240 Voltios ......22.9 Amperios Frecuencia Nominal .....

Table of Contents