Overview Of Controls On Ecotec Pro - Vaillant ecoTEC plus 612 Instructions For Use Manual

Wall hung room sealed fan assisted condensing boilers
Table of Contents

Advertisement

Hot water supply active
(ecoTEC plus combination boilers only)
Illuminated:
(ecoTEC system boilers only)
Illuminated:
Flashing:
Warmstart system active
(ecoTEC plus combination boilers only)
Illuminated:
Flashing:
Internal pump is running
Gas valve is activated
Flame with cross:
Boiler is at lock out and will display fault code
Flame without cross:
Normal burner operation
4.2

Overview of controls on ecoTEC pro

11
10
9
8
7
Fig. 4.3 ecoTEC pro controls
1
Display indicating the current heating flow tempera-
ture, the pressure in the heating system or additional
information
2 Indicator lights to display the current operating mode
3 The "i" information button
4 Built in control/timer (if fitted)
5 Pressure gauge displaying the pressure in the heat-
ing system
6 Main ON/OFF control
7 "+" button for moving forward in the display
8 "-" button for moving back in the display or for dis-
playing the pressure in the heating system
9 "Reset" button
Instructions for use ecoTEC
Hot water demand
Heating of an indirect hot water
cylinder turned on
Heating demand from the hot
water cylinder, burner on
Warmstart turned on
Warmstart demand, burner on
i
F
P
10 Maximum radiator temperature control
11 Maximum hot water temperature control and warm-
start ON/OFF
Multifunctional display system
ecoTEC pro boiler has a multifunction display (1). When
the main ON/OFF control is in the "ON" position the dis-
play will normally show the system CH flow temperature
of water in the boiler circuit (45 °C in the example),
which confirms that the boiler is functioning correctly.
Fig. 4.4 ecoTEC pro indicator lights
1
2
1
Display indicating flow temperature or the system
3
pressure or the relevent fault code.
2 Green warmstart indicator
Illuminated = Warmstart switched ON
Not illuminated = Warmstart is switched OFF and
there is no demand for hot water
4
Flashing = There is either a demand for hot water or
warmstart
3 Yellow indicator
bar
Illuminated = Main burner ignited
5
4 Red indicator
Illuminated = Boiler is at lock out and will display
6
fault code
As long as this symbol appears in the display, a
heating flow temperature and hot water outlet
temperature is set by the vrnetDIALOG accesso-
ry, which means the appliance uses temperatu-
res other than those set using the controls (10)
and (11).
This condition can only be ended:
- using vrnetDIALOG or
- by a change in temperature at controllers (10)
or (11) of more than 5 K.
This condition cannot be ended:
- with the "Reset" button (9) or
- by turning the appliance off or on.
Operation 4
i
F
P
1
2
bar
3
4
7