Omron IntelliSense BP762 Instruction Manual

Omron IntelliSense BP762 Instruction Manual

7 series plus blood pressure monitor with comfit cuff

Advertisement

INSTRUCTION MANUAL
7 series Plus
Blood Pressure Monitor
with ComFit
Cuff
TM
BP762
Model

Advertisement

Table of Contents
loading

Summary of Contents for Omron IntelliSense BP762

  • Page 1 INSTRUCTION MANUAL 7 series Plus Blood Pressure Monitor with ComFit Cuff BP762 Model...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Before Using the Monitor Introduction ..........3 Safety Information .
  • Page 3: Before Using The Monitor

    Before Using the Monitor INTRODUCTION Thank you for purchasing the Omron ® 7 series Plus BP762 Automatic Blood Pressure Monitor with ComFit Cuff. Fill in for future reference. DATE PURCHASED: __________________ SERIAL NUMBER: ____________________ • Staple your purchase receipt here •...
  • Page 4: Safety Information

    SAFETY INFORMATION To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual. SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL Indicates a potentially hazardous situation which, if not avoided, could result in death or WARNING serious injury.
  • Page 5 Do not use a cellular phone near the device. It may result in an operational failure. Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
  • Page 6: Risk Of Electrical Shock

    Do not submerge the device or any of the components in water. Store the device and the components in a clean, safe location. Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the...
  • Page 7: Before Taking A Measurement

    BEFORE TAKING A MEASUREMENT To ensure a reliable reading follow these recommendations: 1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement. 2.
  • Page 8: Operating Instructions

    Operating Instructions KNOW YOUR UNIT Main Unit: Display SET Button USER ID Selection Switch Memory ( ) Button Up/Down Start/Stop Button ) Buttons Battery Compartment Air Jack AC Adapter Jack...
  • Page 9 KNOW YOUR UNIT Components: Housing Air Tube Cord AC Adapter Air Plug (Connects to Air Jack) Arm Cuff INSTRUCTION MANUAL 7 series Plus Blood Pressure Monitor with ComFit Cuff BP762 Model Instruction Manual Storage Case Quick Start Guide...
  • Page 10: Unit Display

    UNIT DISPLAY Irregular Heartbeat Symbol Date/Time Display Average Value Symbol USER ID Symbol (A/B) Memory Symbol Systolic Blood Pressure Movement Symbol Blood Pressure Level Indicator Diastolic Blood Pressure Deflation Symbol Heartbeat Symbol Cuff Wrap Guide Low Battery Indicator Pulse Display / Memory Number...
  • Page 11: Display Symbols

    DISPLAY SYMBOLS IRREGULAR HEARTBEAT SYMBOL ( When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values. An irregular heartbeat rhythm is defined as Normal Heartbeat a rhythm that varies by less than 25% from Pulse...
  • Page 12: Heartbeat Symbol

    DISPLAY SYMBOLS Internationally recognized guidelines for upper limit of normal home blood pressure readings are as follows: Home Guideline for Upper Limit of Normal BP Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on age and morbidity.
  • Page 13: Using The Ac Adapter

    The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position. NOTES: • Use only the authorized Omron AC Adapter that came with this monitor. • We recommend you install the batteries even if the AC Adapter is used.
  • Page 14 USING THE AC ADAPTER TO CONNECT THE AC ADAPTER Insert the AC Adapter Plug into Housing the AC Adapter Jack on the back side of the monitor as illustrated. Plug the AC Adapter into a 120V AC outlet (60 cycles). Cord TO DISCONNECT THE AC ADAPTER Hold the Housing to remove the AC Adapter from the electrical...
  • Page 15: Battery Installation

    BATTERY INSTALLATION Battery Cover 1. Remove the battery cover by pulling the hook up while pushing it in the direction of the arrow. 2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
  • Page 16 BATTERY INSTALLATION BATTERY REPLACEMENT Low Battery Indicator When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended. CAUTION If battery fluid should get in your eyes, immediately rinse with plenty of clean water.
  • Page 17: Setting The Date And Time

    SETTING THE DATE AND TIME Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.
  • Page 18: Setting Date And Time

    SETTING THE DATE AND TIME 1. TO START THE SETTING Press the SET button to adjust the date and time. The year flashes on the display. 2. SETTING THE YEAR The year can be set between 2010 and 2040. When the display reaches 2040, it will return to 2010.
  • Page 19 SETTING THE DATE AND TIME 3. SETTING THE MONTH Press the Up button ( ) to advance by one month. Press the SET button to set the current month. The day flashes on the display. 4. SETTING THE DAY Press the Up button ( ) to advance by one day.
  • Page 20 SETTING THE DATE AND TIME 5. SETTING THE HOUR The time is set using AM or PM. Press the Up button ( ) to advance by one hour. Press the SET button to set the current hour. The minute flashes on the display. 6.
  • Page 21: Applying The Arm Cuff

    APPLYING THE ARM CUFF CAUTION Read all of the information in the instruction manual and any other literature in the box before operating the unit. CAUTION This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
  • Page 22 APPLYING THE ARM CUFF 3. Hold the thumb grip on the cuff Thumb Grip securely with your right hand. Cloth Fastener 4. Turn the palm of your left hand upward. 5. Apply the cuff to your left upper arm so the blue stripe is on the inside of your arm and aligned with your middle finger.
  • Page 23 APPLYING THE ARM CUFF 6. Wrap the cuff firmly in place around your arm using the cloth fastener.
  • Page 24: Applying The Cuff On The Right Arm

    APPLYING THE ARM CUFF APPLYING THE CUFF ON THE RIGHT ARM When taking a measurement using the right arm use this instruction for Step 5 on page 22. Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm.
  • Page 25: Taking A Measurement

    TAKING A MEASUREMENT The monitor automatically determines your ideal inflation level. In rare circumstances when a higher inflation may be necessary, the monitor automatically re-inflates the cuff up to 30 mmHg higher than the initial inflation and restarts the measurement. WARNING Contact your physician for specific information about your blood pressure.
  • Page 26 TAKING A MEASUREMENT 1. Press the START/STOP button to turn the monitor on. All symbols appear on the display. 2. Select your USER ID (A or B). 3. Sit on a chair with your feet flat on the floor. Place your left arm on a table so the cuff is level with your heart.
  • Page 27 TAKING A MEASUREMENT 4. Press the START/STOP button. The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically determines your ideal inflation level. This monitor detects the pulse during inflation. Do not move your arm and remain still until the entire measurement process is completed. NOTE: To stop the inflation or measurement, press the START/STOP button.
  • Page 28 TAKING A MEASUREMENT 6. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed. 7. Press the START/STOP button to turn the monitor off. NOTE: The monitor will automatically turn off after two minutes. WARNING Contact your physician for specific information about your blood pressure.
  • Page 29: Special Conditions

    TAKING A MEASUREMENT SPECIAL CONDITIONS CAUTION Inflating to a higher pressure than necessary may result in bruising where the cuff is applied. If your systolic pressure is known to be more than 220 mmHg, press and hold the START/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
  • Page 30: Using The Memory Function

    USING THE MEMORY FUNCTION The monitor is designed to store the blood pressure and the pulse rate in the memory for two people (USER A and USER B) every time a measurement is completed. The monitor automatically stores up to 60 sets of measurement values (blood pressure and pulse rate) for each user (A and B).
  • Page 31: To Display The Measurement Values

    USING THE MEMORY FUNCTION TO DISPLAY THE MEASUREMENT VALUES 1. Press the START/STOP button to turn the monitor on. 2. Select your USER ID (A or B). 3. Press the Memory button ( The Average Symbol ( ) appears on the display when the average reading is shown.
  • Page 32: To Delete All Values Stored In The Memory

    USING THE MEMORY FUNCTION TO DELETE ALL VALUES STORED IN THE MEMORY The values stored in the memory are deleted by USER ID. You cannot partially delete values stored in the memory. All values will be deleted. 1. Press the START/STOP button to turn the monitor on. 2.
  • Page 33: Care And Maintenance

    Care and Maintenance CARE AND MAINTENANCE To keep your blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the storage case when not in use. Make sure the AC adapter is placed under the main unit so that it does not damage the display.
  • Page 34 CARE AND MAINTENANCE Use the unit consistent with the instruction provided in this manual. CAUTION Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components. CAUTION Use only Omron authorized parts and accessories.
  • Page 35: Error Indicators And Troubleshooting Tips

    ERROR INDICATORS AND TROUBLESHOOTING TIPS ERROR INDICATORS SYMBOL CAUSE CORRECTION Insert the plug securely. Refer to “Applying the Air plug disconnected. Arm Cuff”. Apply the arm cuff correctly. Refer to “Applying Arm cuff not applied correctly. the Arm Cuff”. Air is leaking from the arm cuff. Replace the cuff with the new one.
  • Page 36 ERROR INDICATORS AND TROUBLESHOOTING TIPS TROUBLESHOOTING TIPS PROBLEM CAUSES AND SOLUTIONS No power. Replace all four batteries with new ones. No display appears on the unit. Check the battery installation for proper placement of the battery polarities. Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, Measurement values appear...
  • Page 37: Fcc Statement

    FCC STATEMENT NOTE: POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 38: Limited Warranty

    OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY. OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTAIL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
  • Page 39: Specifications

    SPECIFICATIONS Model: BP762 (HEM-7220-ZCS) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve Rapid Air Release: Automatic exhaust valve Measurement Method: Oscillometric method...
  • Page 40 Manufactured by OMRON HEALTHCARE Co., Ltd. Made in China Distributed by: Omron Healthcare, Inc. 1200 Lakeside Drive Bannockburn, IL 60015 www.omronhealthcare.com Copyright © 2010 Omron Healthcare, Inc.

Table of Contents