Telephone buttons You can use the following types of telephones to program your MICs system: M7310 or M7324 Norstar telephones or T7316 or T7316E Business Series Terminal. This guide uses the Business Series Telephone button icons for programming procedures. Refer to the table below for the keycap icons that correspond to the programming commands. Business Series Terminals Norstar telephones T7316, T7316E...
Contents Telephone buttons ii General information 1 Installed equipment 2 Programming overview (Profiles 1 and 4) 3 Programming overview (Profiles 2 and 3) 6 Programming overview MICS-XC (Companion) 9 Companion programming charts 13 System LID (Companion sets for MICS-XC systems) 13 Software keys 13 SysID 13 Companion ID 13...
Page 4
Profile 19 Dialpad 19 Template 19 Start DN 19 Terminals&Sets 20 Line Access 20 Capabilities 21 Name 22 User prefernces 22 Button prgrming 23 Model M7100/T7100 Button Programming 23 Model M7208/T7208 Button Programming 24 Model M7310 Button Programming 25 Model T7316 Button Programming 27 Model T7316E and KIM Button Programming 28 KIM module 29 Model M7324 Button Programming and CAP Assignments 30...
Page 5
Line restrns 44 Remote restrns 44 Telco features 44 Services 45 Ringing service 45 Restrn service 46 Routing service 47 If PRI-A, PRI-B, PRI-C, or PRI-D 48 If service type requires service id 48 If Protocol is SL-1 or TIE service type 48 Using line pools to create a dialing plan 48 Dest codes 49 Dest codes 50...
Page 6
Remote access 59 Rec’d # length 60 DN length 60 National length 60 Make / Break 60 Business name 60 CbC limits 60 Release reasons 60 Hospitality 61 SM sets 61 Network Services 61 ETSI (Profile 2, only) (software key required) 61 MCDN (Profile 1, 2, and 3, only) (software key required) 61 Telco features 62 VMSg ctr tel#s 62...
Page 7
StnMod 71 Maintenance 72 System version 72 Sys test log 73 Sys Admin Log 74 Network evt log 75 Template specific defaults 76 Terminals&Sets defaults 76 Line Access 76 Restrictions 76 Telco features (Feature assignmnt) 77 Lines defaults 77 Trunk/Line data (Target lines) 77 Trunk/Line data (Digital and Analog loopstart) 77 Trunk/Line data (Digital and Analog Groundstart) 78 Trunk/Line data (Digital and E&M lines) 78...
Page 8
viii Modular ICS 6.1 Programming Record P0603536 02...
General information Customer/Company Supplier Address Customer service representative Telephone Telephone Billing number Installer System coordinator Installation date All defaults for the default templates are shown in bold and underlined text. Copying set programming You can use the COPY command to copy programming from one telephone to other set, a range of sets or all the sets. Depending on where the display button is pressed, you will copy either all the programming for a telephone or only the programming found under one of the individual sub-headings.
Programming overview (Profiles 1 and 4) Defaults are shown in bold and underlined Allow redirect Pool Ans mode Manual Redirect ring Ans with DISA Profile PROF 1 Lines Intrusion Link at CO Protect Lvl None Aux. ringer ATA settings Signal Winkstart Show line:_ Dialpad...
Page 12
Programming overview (Profiles 1 and 4) continued ... Defaults are shown in bold and underlined Sched:Sched 5 tagging feature, you must specify Mode: None Broadcast Hunt delay: (sequential a name for the speed dial. Sched:Sched 6 None Services mode only) Sched:Night If busy: BusyTone...
Page 13
Programming overview (Profiles 1 and 4) continued ... Defaults are shown in bold and underlined Priv DN len Release reasons SysID I800 None (8 digits) Type None Text: None PrivNetId Password keys None Loc code CO fail None TIA-547A Hospitality Key 1 (8 digits) Priv DN len...
Programming overview (Profiles 2 and 3) Defaults are shown in bold and underlined Config Protect Lvl None ATA settings V.35 Profile Lines DS0 rate PROF 1 ATA ans timer TxClk src Auto ATA use Off site TxClk invrsn Show line:_ Data invrsn Msglndicate None...
Programming overview (Profiles 2 and 3) continued ... Defaults are shown in bold and underlined Ringing service Common settings Pswd 00 (If T1 and DID) Profile 3 only None Trunk Type User flt None Ringing groups Control sets Line type Line flt Pool A None...
Programming overview (Profiles 2 and 3) continued ... Defaults are shown in bold and underlined Change DNs Prfx:Deflt Attn attempts: PrivNetID Retry intrvl: DN length Type Slave Attn duration: Dial time out Old DN:_ Max. 7 digits BchanSeq Descend Time format 12hr New DN:_ Max.
Programming overview MICS-XC (Companion) Defaults are shown in bold and underlined Network evt log Allow redirect Pool Redirect ring Profile PROF 1 Provisioning Lines Intrusion Protect Lvl None Tests ATA settings Show line:_ Dialpad ATA ans timer Q, Z:0 CSU stats Trunk/Line data ATA use Off site...
Page 18
Programming overview MICS-XC (Companion) continued ... Defaults are shown in bold and underlined Distinct Ring Sched:Sched 5 tagging feature, you must specify None None a name for the speed dial. Sched:Sched 6 Ans mode None Services Manual Sched:Night Ans with DISA Service Passwords Link at CO...
Page 19
Programming overview MICS-XC (Companion) continued ... Defaults are shown in bold and underlined Direct-dial 637: Hour: Portable Minutes: State System prgrming Available Alarm D-Dial 1 Intrnl Companion Attn attempts: (MICS-XC only) Use prime line Retry intrvl: Attn duration: Registration CAP/KIM assignment Hunt groups Time format 12hr...
Page 20
Programming overview MICS-XC (Companion) continued ... Defaults are shown in bold and underlined Discon timer Answer timer System version (If T1 card) (If BRI card) Card type Card type Port/DN status Lines Loops Discon timer Loop aaa Module status Type Answer timer Protocol CO fail...
Companion programming charts The next four pages contain charts specific to programming the Companion information. All other programming for MICS-XC systems are the same as for the other MICS systems, and follows this section. System LID (Companion sets for MICS-XC systems) (System prgrming;...
Radios and Cells (Companion CT2+ sets for MICS-XC systems) (System prgrming; Companion; Radios and System prgrming; Companion; Cells) KSU block Base Station / RPI units RPI wiring KSU Antenna device type port: number equipment location block number (identify with number or Power ‡...
Hardware Modules Mod 03 StnMod DataMod TrunkMod Mod 04 StnMod DataMod TrunkMod Mod 05 StnMod DataMod TrunkMod Mod 06 StnMod DataMod TrunkMod Mod 07 StnMod DataMod TrunkMod Mod 08 StnMod DataMod TrunkMod Mod 09 StnMod DataMod Mod 10 StnMod DataMod Mod 11 StnMod DataMod...
To record additional information, photocopy this page before using. Installed telephones and other devices Name or location Telephone model CAP/ Port Default DN New DN (max. 7 digits) (max. 7 digits) *. Change DNs in System prgrming; Change DNs. Record old and new DNs here. Modular ICS 6.1 Programming Record P0603536 02...
Photocopy pages before using. Terminals&Sets Line Access (Terminals&Sets: Line access) Sets: (max. 7 digits) Line assignment List 3 digit line number and _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ circle line assignment.
Photocopy pages before using. Button prgrming Enter the button programming information for each telephone in the appropriate table. Model M7100/T7100 Button Programming M7100/T7100 Prgrming All defaults Last No. P0603536 02 Modular ICS 6.1 Programming Record...
Model M7208/T7208 Button Programming M7208/T7208 Prgrming Square Centrex Hybrid Line 1 Line Line 1 Pick-Up Line <XX> <XX> Line 2 Transfer Line pool Transfer Transfer Last No. Last No. Page Link Page Page Page Conf/ Conf/ Trans Trans Speed Speed Dial Dial Intercom...
Model M7310 Button Programming B11/12 B19/20 B27/28 B13/14 B21/22 B29/30 B23/24 B15/16 B31/32 B17/18 B25/26 B33/34 M7310 Prgrming Square Centrex Hybrid Line 1 Line Line 1 Line <xx> <xx> Line 2 Transfer Line Pool Transfer Transfer Call Fwd Pickup Page Link Page Page...
Page 34
M7310 Prgrming Square Centrex Hybrid B22 (shift) Set 238 Set 227 B24 (shift) Set 239 Set 228 B26 (shift) Set 240 Set 229 B28 (shift) Set 241 Set 230 B30 (shift) Set 242 Set 231 B32 (shift) Set 243 Set 232 B34 (shift) Set 244 Modular ICS 6.1 Programming Record...
Model T7316 Button Programming Line numbering starts here T7316 Prgrming Square Centrex Hybrid Line 1 Line <xx> Line 1 Line <xx> Line 2 Transfer Line Pool Transfer Transfer Call Fwd Pickup Page Link Page Page Page Conf/Trans Last No. Voice Call Intercom Intercom Internal autodial...
Model T7316E and KIM Button Programming Line numbering starts here T7316E Prgrming Square Centrex Hybrid Contrast Show Time Privacy Blank Privacy Blank Blank SavNum redial Blank Sav Num redial Blank Sav Num redial System Park Blank System Park Blank System Park Send Message Speed dial Line <XX>...
KIM module Note: MICS systems will support up to five central answering positions. This includes T7324 telephones with CAP modules and T7316E telephones with EKIMs. OKIM or EKIM KIM1 Prgrming KIM1 Prgrming KIM1 Prgrming OKIM or EKIM KIM2 Prgrming KIM2 Prgrming KIM2 Prgrming...
Model M7324 Button Programming and CAP Assignments M7324 Prgrming Square Centrex Hybrid Line 1 Line <XX> Line 1 Line <XX> Line2 Line Pool Transfer Call Fwd Speed Dial Last No. Saved Link Saved Saved Saved No. Conf/Trans Transfer Grp Pickup Voice Call Page Gnrl Intercom...
Page 39
Prgrming Default Prgrming Default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default No default...
User speed dial (Terminals&Sets: User speed dial) Spd# Speed dial number (max. 24 digits) Use prime line Pool code ____ (256-279) Use line: ____ Use routing tabl Modular ICS 6.1 Programming Record P0603536 02...
Telco features (Terminals&Sets:Telco features) Feature assignmnt (Terminals&Sets;Telco features; Feature assignmnt) Sets: (max. 7 digits) names: (max. 7 char.) Caller ID set Extl VMsg set Line#: Line#: Line#: Line#: Line#: Line#: Line#: 1stDisplay (Terminals&Sets;Telco features;1st Display) Name Name Name Name Name Name Name Numbr...
If T1 and Groundstart Line no. (3 digits) Telephone number Trunk type Ground Ground Ground Ground Line type Public Public Public Public Private to: _______ Private to: _______ Private to: _______ Private to: _______ Pool _____ Pool _____ Pool _____ Pool _____ Dial mode Pulse...
If T1 and E&M Line no. (3 digits) Telephone number Trunk type E&M E&M E&M E&M Line type Public Public Public Public Private to: _______ Private to: _______ Private to: _______ Private to: _______ Pool _____ Pool _____ Pool _____ Pool _____ Dial mode Pulse...
If T1 and DID (Profiles 1, 3 and 4 only) Line no. (3 digits) Telephone number Trunk type Line type Public Public Public Public Private to: _______ Private to: _______ Private to: _______ Private to: _______ Pool _____ Pool _____ Pool _____ Pool _____ Dial mode...
If BRI-2 or BRI-ST (ISDN) (BRI-2 for Profiles 2 and 3 only) Line no. (3 digits) Telephone number (supplied by the CO) Trunk type BRI-2 BRI-ST BRI-2 BRI-ST BRI-2 BRI-ST BRI-2 BRI-ST Line type Public Public Public Public Private to: _______ Private to: _______ Private to: _______ Private to: _______...
If PRI (ISDN) (Profiles 1 and 4 only) Line no. (3 digits) Telephone number (supplied by the CO) Trunk type Line type PRI-A PRI-B PRI-C PRI-A PRI-B PRI-C PRI-A PRI-B PRI-C PRI-A PRI-B PRI-C PRI-D PRI-D PRI-D PRI-D PrimeSet None None None None...
Restrictions Not available for Target lines. Restriction filter tables are provided under Terminals&Sets. Line restrns (Lines; Restrictions; Line restrns) Name (max. 7 char.) Line no. (3 digits) Normal Night Evening Lunch Sched 4 Sched 5 Sched 6 Remote restrns (Lines; Restrictions; Remote restrns) Name (max.
Photocopy pages before using. Services Ringing service (Services; Ringing Service/Ringing groups) (Maximum of 30 sets for each Ringing group) A=Assigned; U=Unassigned Ring grp: Ring grp: Ring grp: Ring grp: Ring grp: Ring grp: Ring grp: Ring grp: Ring grp: P0603536 02 Modular ICS 6.1 Programming Record...
Ringing Service (Services; Ringing Service) (continued) Schedule 6 Schedule 6 Schedule Ctrl set: Ctrl set: Ctrl set: Service Auto Service Auto Service Auto Manual Manual Manual Trunk answer Trunk answer Trunk answer ExtraDial ExtraDial ExtraDial ExtraDial Line settings Ring grp Aux.
Routing service (Services; Routing service) Route # DialOut Use pool (001-999) no number (Pools PRI-A, PRI-B, are used with all profiles; PRI-C and PRI-D are only used by Pro- or enter number files 1 and 4) C D E F M N O PRI-A PRI-B PRI-C PRI-D C D E F M N O PRI-A PRI-B PRI-C PRI-D...
If PRI-A, PRI-B, PRI-C, or PRI-D (Services; Routing service) (Profiles 1 and 4 only) Protocol: Srvctype: NI-2 Public OUTWATS DMS100 DMS250 AT&T 4ESS I800 If service type requires service id (Services; Routing service) (Profiles 1 and 4 only) ServiceID: None <valid service id #>...
Dest codes (Services; Routing service; Dest codes) Service Schedule Normal Rte DstCode Use route Digit First route Digit Second route Digit Third route Digit Absorb Absorb Absorb Absorb (max. 12 digits) (001-999) (001-999) (001-999) (001-999) length length length length All 0 1 All 0 1 All 0 1 All 0 1...
Dest codes (continued) Service Schedule DstCode First route Digit Second route Digit Third route Digit Absorb Absorb Absorb (max. 7 digits) (001-999) (001-999) (001-999) length length length All 0 All 0 1 All 0 1 All 0 All 0 1 All 0 1 All 0 All 0 1...
Activating routing schedules (Services: Routing Service) Schedule Schedule 1 Schedule 2 Schedule 3 Schedule 4 Schedule 5 Schedule 6 Mode Auto Auto Auto Auto Auto Auto Manual Manual Manual Manual Manual Manual Overflow Common settings (Services; Common settings) Control sets (Services;...
Photocopy pages before using. Sys speed dial Speed dial #: Number to dial PL = Use prime line Display Name (max. 16 char.) (001-255) digits pass (max. 24 digits) PC = Line Pool code: Default is speed dial code restr’n RT = Use routing tabl: L = Use Line: ___ Modular ICS 6.1 Programming Record...
Time&Date Hour: Minutes: Year: Month: Day: System prgrming Hunt groups (System prgrming: Hunt groups) Name: (7 characters) Group Number: DN _______ DN _______ DN _______ DN _______ DN _______ Members Appr only Appr only Appr only Appr only Appr only Appr&Ring Appr&Ring Appr&Ring...
Featr settings (System prgrming; Featr settings) Background music On hold Tones Music Silence Receiver volume Use sys volume Use set volume Camp timeout 30 45 300 600 Park timeout 30 45 300 600 Park mode Lowest Cycle Trnsfr callbk DRT to prime DRT delay 23 4 6 10 Held reminder...
Use Prime line Use Prime line Use Prime line Use Prime line Use Prime line (if D-Dial=Extrnl) Use line Use line Use line Use line Use line Pool code Pool code Pool code Pool code Pool code Use routing table Use routing table Use routing table Use routing table...
Page 66
Carrier Codes Prefix:10 ID length: 3 Prefix: ID length Prefix: ID length Prefix: ID length Prefix: ID length Prefix: ID length Modular ICS 6.1 Programming Record P0603536 02...
Remote access (System prgrming; Remote access) Remote access Pkg # Line pool access Remote page (Note that Line Pool access PRI-C and PRI-D are applicable to Profiles 1 and 4 only.) Package 00 permits no access to line pools PRI-A PRI-B PRI-C PRI-D (If PRI then PRI-A is default) PRI-A PRI-B PRI-C PRI-D (If PRI then PRI-A is default)
Photocopy pages before using Hospitality (System prgrming; Hospitality) Room/desk info Sets: (max. 7 digits) Room #: Adm pwd req’d Call Restrns Vacant: Use flt: __ Basic: Use flt: __ Mid: Use flt: __ Full: Use flt: __ Service time Hour: Minutes: Alarm Attn attempts:...
Telco features VMSg ctr tel#s (Telco features; VMSg ctr tel#s) VMsg center 1 VMsg center 2 VMsg center 3 VMsg center 4 VMsg center 5 line routing tbl line routing tbl line routing tbl line routing tbl line routing tbl tele#_______________ tele#_______________ tele#_______________...
If card is a PRI card (Profiles 1 and 4 only) Card type Lines Protocol protcl NI-2 DMS100 DMS250 4ESS SL-1 (does not show unless MCDN is active) (Not shown if only one protocol available) PrivNetID range: 1-127 BchanSeq Ascend Descend (Default is Descend unless SL-1 Master)
If card is an ETSI PRI card (Profile 2 only) Card type Lines Protocol EURO SL1 (does not show unless MCDN is active) PrivNetID 1 (does not show unless MCDN is active) range: 1-127 BchanSeq Ascend Descend (does not show unless MCDN is active) (Default is Descend unless SL-1 Master) User (does not show unless MCDN is active)
For T & NT only (for Profiles 1 and 4 only) SPID__ # of B-channels Network DNs DN1: Call type Voice Data Both DN2: Call type Voice Data Both DN3: Call type Voice Data Both DN4: Call type Voice Data Both DN5: Call type...
For S (for Profiles 2 and 3 only) Sampling Adaptve Fixed Assign DNs *LP ___ * LP ___ Show DN:__ Assigned Availabl Loop DN:_ None ISDN DN For T (for Profiles 2 and 3 only) ClockSrc Primary Secndry TimMstr (On core only) Ovlap recving Public digit length 789101112131415...
Page 77
MICS-XC (additional modules) Mod 09 StnMod Mod 10 StnMod Mod 11 StnMod Mod 12 StnMod Mod 13 (For use by StnMod Companion) Mod 14 (For use by StnMod Companion) P0603536 02 Modular ICS 6.1 Programming Record...
Page 78
TrunkMod (Profiles 1 and 4 only) (BRI cards and off-core DTI cartridges a re available on Modules 03 and 04 on midi systems, and on Modules 07 and 08 for maxi systems.) (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.) Cd1-Mod3 Loop E&M...
Page 79
TrunkMod (Profile 2 ) (BRI cards are available on Modules 03 and 04 on midi systems, and on Modules 07 and 08 for maxi systems.) (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.) Cd1-Mod3 Loop E&M BRI-2 BRI-ST Cd2-Mod3 Loop E&M BRI-2...
TrunkMod (Profiles 3 ) (BRI cards are available on Modules 03 and 04 on midi systems, and on Modules 07 and 08 for maxi systems.) (MICS-XC systems: TrunkMod cannot be configured for Modules 09-14.) Cd1-Mod3 Loop E&M BRI-2 BRI-ST Cd2-Mod3 Loop E&M BRI-2...
Sys test log (Maintenance; Sys test log) Sys Test Log Log item Time of log item Number of repetitions Modular ICS 6.1 Programming Record P0603536 02...
Page 83
Sys Admin Log (Maintenance; Sys Admin Log) Sys Admin Log Log item Time of log item Number of repetitions Time and date that log was checked P0603536 02 Modular ICS 6.1 Programming Record...
Network evt log (Maintenance; Network evt log) Network Log Log item Time of log item Number of repetitions Time and date that log was checked Modular ICS 6.1 Programming Record P0603536 02...
Template specific defaults For the Norstar MICS 6.1 system, the Square template is the default template. The Centrex, Hybrid, PBX and DID template are also available as an option at startup. For the Norstar MICS-XC 6.1 system, the PBX template is the default template. The DID template is also available as an option at startup.
Telco features (Feature assignmnt) Setting Square Centrex Hybrid Set 221: Call log set default target line: Y other sets: other lines: N Extl VMsg set default target line: other lines: N Lines defaults Trunk/Line data (Target lines) Setting Square Centrex Hybrid Rec’d #: None...
Trunk/Line data (Digital and Analog Groundstart) Setting Square Centrex Hybrid Line type Public Lines Pool Lines Pool 001 to 030: Pool A 001 to 030: Pool A 031 to 060: Public 031 to 060: Pool B 061 to 336: Public 061 to 068: Pool C 069 to 076: Pool D 077 to 084: Pool E...
Trunk/Line data (Digital and Analog DID) Setting Square Centrex Hybrid Line type Public Lines Pool Lines Pool 001 to 030: Pool A 001 to 030: Pool A 031 to 060: Public 031 to 060: Pool B 061 to 336: Public 061 to 068: Pool C 069 to 076: Pool D 077 to 084: Pool E...
Glossary of programming headings and settings This section presents the programming hierarchy in the Norstar Modular ICS/Modular ICS-XC interface. The dots each represent a level below the top level Below the 3rd level •••• ••••• •••••• Top Level Level 1 Level 2 Level 3 •••••••...
Page 91
Use the following commands to change defaults and configure the lines and sets to suit your system requirements. Use Installer or Administrator access codes. Terminals & Sets These commands allow you to assign settings to each telephone (DN). • Show set:_ Enter the DN of the telephone you want to program.
Page 92
••• DND on Busy Select whether or not an incoming call rings if the user already is on another call. ••• Handsfree Select whether handsfree will be available to a telephone. ••• HF answerback Select whether a user can automatically answer a voice call without lifting the Å...
Page 93
•••• ATA dvc Set to enhance connectivity for telephones connecting to PRI and BRI lines through an ATA module. Choose Telephon for telephones, and Modem for other devices, such as fax machines. ••• SM Supervisor Select whether the telephone can be used to perform silent monitoring on Hunt groups.
Page 94
•••••• Pg Zone All:F610 Page internally by zone. Zone 0 pages all zones. •••••• Page Zone 1:F611 •••••• Page Zone 2:F612 •••••• Page Zone 3:F613 •••••• Page Zone 4:F614 •••••• Page Zone 5:F615 •••••• Page Zone 6:F616 •••••• Page Spkr:F62 Page through an external loudspeaker system.
Page 95
•••••• Show time:F803 Use to display the time and date while on a call. •••••• Wait:Dial:F804 Use to program an external autodial number to cause the system to wait to receive dial tone from another system before proceeding with the dialing sequence.
Page 96
•••••• Voice Deny:F88 Use to prevent the set from receiving voice calls. •••••• MCID:F897 ESTI lines only: If service is active from the service provider, this feature saves current caller information at the service provider system. •••••• Language:F*501 Select the display language. (501 = first language; 502 = second language; 503 = third language ••••••...
Page 97
••• Line/set rstrns Assign restriction filters to certain lines on each set in your system. •••• Show line:_ Select the line on this telephone for which the restriction will apply. For each line, enter the number (two-digit) of the restriction filter to apply •••••...
Page 98
••• Auto privacy Select whether a line will be private to the individual on a call, or whether it can be shared by other users while a call is in progress. The Privacy setting ² ¡ Ü can be suspended for individual calls using the privacy feature ( •••...
Page 99
••• Restrn filters These are sets or groups of restrictions and associated overrides that specify the external numbers or feature codes that cannot be dialed from a telephone or line. •••• Show filter:_ Enter the two-digit filter number. ••••• Restrn flt 00 Filter 00 is pre-set with no restrictions.
Page 100
•• Sched:Night Select options for your ringing service. ••• Service Select how you want your service activated. Allow the telephone to answer incoming calls arriving at any telephone on the ••• Trunk Answer system. ••• ExtraDial Enter the internal telephone number of the Extra-Dial telephone. This allows you to assign an additional Direct-dial telephone in the Norstar system for each schedule you use.
Page 101
•• Dest codes Define which routes are used when a destination code is dialed. ••• Show DstCode:_ Up to 500 destination codes are programmable. Enter up to seven digits of the destination code that you want to use to define a route.
Page 102
• Common settings Use these commands to assign settings that are shared by different services. •• Control sets Assign control telephones to turn services on or off. Select lines for settings and services. ••• For lines •••• Show line:_ Enter the number of the line you want to program. ••••...
Page 103
••• Name If you choose No for display digits, enter 16 characters to identify the person or location for a speed dial number. When the number is dialed, the telephone displays the name, not the number. If you want to use the alpha tagging feature, you must specify a name for the speed dial.
Page 104
Time&Date Use these commands to set the system clock to the correct time and date. System prgrming Use these commands to change system-wide settings. These commands allow you to set up incoming calls on a specific DN to be • Hunt groups routed to a group of sets.
Page 105
•• Park mode Select whether the system will use Call Park codes in a sequence from lowest to highest, or use the lowest numbered code that is available when the call is parked. •• Trnsfr callbk Select the number of times a transferred call rings before it returns to the telephone that transferred it.
Page 106
•• Silent Monitor Use this command to determine if the Silent Monitoring feature will emit a conference tone when supervision occurs. (Y = tone; N = no tone) •• CLID Match Use this command to determine how many digits an incoming calls must match to a System Speed Dial listing to allow the speed dial name to display for the call.
Page 107
• Access Codes Use these commands to enter the access codes for: • Line pool • Park prefix • Extrnl code • Direct-Dial • Auto DN • DISA DN •• Line pool codes Enter a line pool access code for each line pool (1-4 digits). A line pool access code cannot start with the same digits as the: •...
Page 108
• Remote access Use these commands to create a system of controlled access to your Norstar system. •• Remote access pkgs Create packages to apply to lines that allow or restrict the remote access to Norstar line pools and/or to paging. •••...
Page 109
• Cells These commands provide information about the cells within the system. •• Show cell:_ Enter the number of the cell you wish to program. Assign a radio to this cell. •• Cell radios ••• Show radio:_ Enter the number of the radio. ••...
Page 110
•• Call Restrns These commands allow you to assign dialing filters to room occupancy states. ••• Vacant This command notes if the Room is empty or occupied. •••• Use flt: Enter the dialing filter for the room state. The filters range from 00 to 99. •••...
Page 111
Keys are required for some system expansion activities and to activate the remote monitoring capability. To obtain the required keys for ISDN PRI, and fixed access trunks/WAN access for Data Modules, call the Nortel Customer Response Center at: 1-800-684-5825. Note: An ISDN PRI key is required for MCDN networking.
Page 112
•••• Protocol •••• PrivNetId Specify the duration of an Open Switch Interval for a Trunk Cartridge. ••• Discon timer ••• Answer timer Select the minimum duration, in seconds, of an answer signal before a call is considered to be answered, for an E&M trunk cartridge. ••...
Page 113
••• D-packet servce Configure the D-packet service for this loop. Only one loop on each card can support D-channel packet service. •••• D-packet servce Turn the D-packet service for this loop on or off. •••• Lp001 Select the loop that supports the D-packet service: •...
Page 114
•••• Config Use to configure the settings for the SDI. ••••• Ptl Select the physical interface used to connect the SDI to the networking equipment. ••••• DS0 rate Select the transmission rate of the channels (Fixed lines) assigned to the SDI. •••••...