FRONT DOOR
INSTALLATION
(packaged separately)
1) Open the two side panels.
2) Slide the door
onto the two hinge
pins making sure
the two pieces
are fl ush together.
See diagram 1.
3) Close the door.
The latch plate
must be cen-
tered around the
alignment pin.
See
diagram 2. If the latch
plate interferes with the
corner of the stove you
may want to angle the
plate slightly so the door
closes easier.
4) The latches should already be at the proper
setting. If they are too hard or too easy
to close, you may want to adjust them by
loosening the latch catch. See diagram 3.
5) Remove the blue plastic protective coating
from the glass.
6) Test the seal around the door by placing
a piece of paper between the unit and the
door, close the door and try to pull the paper
out. If it slips out easily, then the door is
not properly sealed. Tighten or loosen the
latch. See diagram 3.
Diagram 3
Note:
The door latch may require adjust-
ment as the door gasket material
compresses after a few fi res and
after glass replacement. Turn the
latch catch inward or outward to
loosen or tighten.
®
Regency
U38-1 ULTIMATE Freestanding Gas Stove
INSTALLATION
1) Attach the top & bottom louvers to the side
stove panel using 2 screws per side.
Diagram 1
TEST FOR FLUE
A "spillage" test must be made before the
installed unit is left with the customer. Follow
the procedure below:
1) Start all exhaust fans in the home and any
other gas appliances. Then close all doors
and windows.
Diagram 2
2) Light the unit and set controls to maxi-
mum.
3) After fi ve minutes, test that there is a "pull"
on the fl ue by placing a smoke match,
cigarette or similar device which gives off
smoke, on the edge of the draft hood. See
diagrams.
LOUVER
SPILLAGE
INSTALLATION
The smoke should be drawn into the draft
hood. If the smoke is not drawn into the draft
hood, turn the unit off and check for the cause
of lack of draft.
.
Note: If the fl ue is blocked or has a strong
reverse fl ow, the thermally actuated safety
switch mounted in the draft hood will auto-
matically shut off the gas supply within about
10 minutes. If the heater turns off because
of this during the spillage test, check for the
cause of the lack of draft.
The thermally activated safety switch must
be manually reset before fi rst startup.
19