HAMPTON BAY Hampton H35-NG Owners & Installation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

H35 Direct Vent Gas Fireplace
WARNING:
If the information in these instructions are not followed exactly,
a fire or explosion may result causing property damage,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
Tested by:
918-085b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.hampton-fire.com
MODELS:
H35-NG Natural Gas
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
H35-LP Propane
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas sup-
plier, call the fire department.
Owners &
01/09/06

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY Hampton H35-NG

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-085b 01/09/06 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
  • Page 2: Unit Dimensions

    Congratulations! You are the owner of a state-of-the-art Hampton Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H35 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Page Safety Label Support Extension - Round or Square ....... 24 High Elevation ............24 Safety Labels ............4 Gas Connection ............24 System Data Chart ..........24 Installation Aeration Adjustment ..........24 Gas Pipe Pressure Testing ........25 Specifications ............
  • Page 4: Safety Labels

    SAFETY LABEL This is a copy of the label that accompanies NOTE: Hampton units are constantly being each Direct Vent Freestanding Gas Stove. We improved. Check the label on the unit and if have printed a copy of the contents here for there is a difference, the label on the unit is your review.
  • Page 5: Installation

    INSTALLATION tured Home Construction and Safety Standard, IMPORTANT: SAVE PASSAGEWAYS OF THE APPLI- Title 24 CFR, Part 3280, or the current Standard ANCE BE KEPT CLEAN. THESE INSTRUCTIONS of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/ NFPA 501A, and with CAN/CSA Z240-MH Mo- DUE TO HIGH TEMPERATURES, The Direct Vent Freestanding Gas Stove must...
  • Page 6: General Safety Information

    INSTALLATION 4) This appliance is Listed for bedroom instal- 9) To prevent injury, do not allow anyone who CLEARANCES TO lations when used with a Listed Millivolt is unfamiliar with the operation to use the COMBUSTIBLES Thermostat. Some areas may have further fireplace.
  • Page 7: Locating Your Gas Stove

    INSTALLATION LOCATING YOUR OPTIONAL FAN INSTALLATION GAS STOVE Fan Kit Contains: 7) Install locking grommet to power cord and push through hole in the rear panel and give When selecting a location for your stove, en- Qty. Description a 1/4 turn to secure. sure that the clearances listed above are met as Fan Speed Controller with nut, and knob.
  • Page 8: Venting Introduction

    3) Installation of any component part not man- losing warm room air up the chimney. ufactured or approved by Simpson Dura- Vent or FPI Fireplace Products International Note: These flue pipes must not be Ltd. connected to any other appliance.
  • Page 9: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS Hampton H35 Direct Vent Freestanding Gas Stove...
  • Page 10: Rigid Pipe Venting Components List

    INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent Direct VentGS Direct-Temp Direct Vent 6" Pipe Length, Galvanized 4DT-6 6" Pipe Length, Black 908B 4DT-6B 7" Pipe Length, Galvanized 7"...
  • Page 11: Rigid Pipe Venting Systems Horizontal Or Vertical Terminations

    The FPI AstroCap and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI...
  • Page 12: Rotating Elbow For Horizontal Terminations

    INSTALLATION ROTATING 45 ELBOW FOR STRAIGHT HORIZONTAL TERMINATIONS 1) Remove all 4 screws that se- 2) Rotate the elbow 180 cure the elbow to the unit using a 3) Secure the elbow by securing 1/4" magnetic nut driver. it with the 4 screws. Remove all 4 screws and washers VENTING ARRANGEMENTS...
  • Page 13: Venting Arrangements - Horizontal Terminations

    INSTALLATION Venting Arrangements - Horizontal Terminations using Rigid Pipe The two diagrams show all allowable combinations of straight horizontal ter- mination using Rigid Pipe. Restrictor po- sition "A". Riser Vent Termination Dura-Vent Snorkel Termination Venting Arrangements -Straight Horizontal Termination at a De-Rated BTU The diagrams show all allowable combi- nations of straight horizontal termina- tion using Rigid Pipe.
  • Page 14: Horizontal Vienting With Two Elbows

    INSTALLATION Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 With these options, maxi- 3' Min. 2' Max. mum total pipe length is 30 feet with minimum of 8 feet 4' Min. 3' Max.
  • Page 15: Vertical Venting With Two Elbows

    INSTALLATION Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V V + V1 With these options, max. total pipe length is 30 feet with min. 1' Min. 3' Max. 2' Min. of 6 feet total vertical and 2' Min.
  • Page 16: Vertical Termination With Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. THE APPLIANCE MUST NOT BE However, keep the flexible liner as straight as possible , avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
  • Page 17: Horizontal Termination Kit

    INSTALLATION DV STOVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (Part #946-216) includes all the parts needed to install the H35 Direct Vent unit with minimum horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown on page 19.
  • Page 18 INSTALLATION 13) Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14) Attach the 45 elbow onto the starter collar by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2"...
  • Page 19: Dura-Vent Termination Kits

    1 Wall Thimble Cover 1 Horiz. Sq. Term. Cap The FPI AstroCap is certified for installations using FPI venting systems as well as Simpson Dura- Vent® and Direct Vent GS. The FPI AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd.
  • Page 20: Dura-Vent Venting Components Parts List

    INSTALLATION DURA-VENT VENTING Parts not supplied by Dura-Vent wards the wall or ceiling, as much out of view as possible. The final positioning of 946-506/P Vent Guard (Optional) COMPONENTS the pipe and 90 elbow assembly is deter- 640-530 Riser Vent Terminal (Optional) mined by the mounting orientation of the 948-128 Vinyl Siding Shield for Riser...
  • Page 21 INSTALLATION sheet metal strips extending from the vent the vent to run downward. This could cap assembly into the outer wall of the vent cause high temperatures and may pipe. Use the two sheet metal screws present the possibility of a fire. provided to connect the strips to the pipe.
  • Page 22: Offset Chart

    INSTALLATION 7) Ensure vent is vertical and secure the base a plumb bob from the roof to the hole previously drilled in the ceiling, and mark the of the flashing to the roof with roofing rails, spot where the vent will penetrate the roof. slide storm collar over the pipe section and seal with a mastic.
  • Page 23: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    INSTALLATION leaky chimney condition exists. Do not CONVERTING A 4) Pass the flex pipe down through the center operate the appliance until the problem of the chimney system, and center the CLASS-A METAL is corrected. adaptor on the top of the chimney pipe. Drill four 1/8"...
  • Page 24: Cathedral Ceiling Installations

    INSTALLATION half of the flashing should be under the CATHEDRAL CEILINGS WATER SOLUTION OR GAS LEAK shingles. DETECTOR. DO NOT USE OPEN FLAME FOR LEAK TESTING. Round Support (RDS) & 4) Assemble the desired lengths of Black Pipe and Elbows necessary to reach from the Square Support (SQS) appliance adapter up through the support Note: Prior to any pressure testing of...
  • Page 25: Gas Pipe Pressure Testing

    INSTALLATION To adjust the aeration: use the allen key to turn 4) Light the pilot and turn the valve to "ON" CONVERSION FROM the turning gear which will adjust the air shutter. position. Read manometer. NATURAL GAS TO Open the air shutter for a blue flame or close it for a yellower flame.
  • Page 26 INSTALLATION 4) Remove and discard the 3 pressure regu- 9) Reinstall new burner orifice LP stamped lator mounting screws (A), pressure regu- #51 and tighten. lator tower (B) and diaphragm (C). 10) Reverse steps 3) to 2). 5) Insure that the rubber gasket (D) is properly positioned and install the new HI/LO pres- 11) Attach the Conversion label "This unit has sure regulator assembly to the valve using...
  • Page 27: Conversion To Lower Btu

    INSTALLATION Conversion Kit to Lower Btu Rating for H35 Hampton Natural Gas - Kit #: 740-950 Propane - Kit # 740-952 THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Natural Gas Conversion Kit 740-950 Contains: 5) Unscrew the 2 Rear Log Pins and move to the front hole position.
  • Page 28: Gas Fireplace - Optional Brick Panel

    INSTALLATION 4) Before installing the side brick panels, loos- 10) Adjust Vent restrictor setting: To set the LOG SET en the screws for the brick tabs enough so Vent restriction as indicated in the diagram, INSTALLATION that you can slide the brick tabs on to the simply loosen the screws and push the screws easily but that the tabs are secure.
  • Page 29 INSTALLATION 7) Place the Left Top Log D)02-46 on the pin 11) Position notch in Front Right Log G)02-48 on 3) Place Rear Log A)02-43 on the two pins on on Log B)02-56 and on top of the cutout on Log F)02-47 and push the bottom right edge the rear log support.
  • Page 30: Optional Door Installation

    INSTALLATION 2) Slide the Optional Side Tile Inset into the OPTIONAL DOUBLE DECORATIVE DOOR side panel, over the spring clip. DOOR INSTALLATION GRILL INSTALLATION 3) Repeat for other side. 1) Secure the Top Door Clip into the Top Front 1) Hook the Top Clip on the Decorative Door Top Tile Inset Casting.
  • Page 31: Door Hinge Removal

    INSTALLATION DOOR HINGE 4) Pull all four door hinges out from the sides of the front casting. REMOVAL 1) Remove the cast top by lifting it off of the stove. 5) Use a 7/16" wrench to remove the screws that secure the door hinges. 2) Release the catches on the left and right side of the stove that secure the glass.
  • Page 32: Wiring Diagram

    INSTALLATION WIRING DIAGRAM - H35-NG & H35-LP If any of the original wires as supplied with the Caution: Ensure that the wires do WARNING: Electrical Grounding appliance must be replaced, it must be replaced not touch any hot surfaces and are Instructions with CSA type SEW (200 C) or its equivalent.
  • Page 33: Final Check

    OPERATING INSTRUCTIONS seen when lighting the unit - the logs have 6) Rotate the flame height regulator to adjust 1) Choose a convenient location on the wall to been incorrectly positioned. the flame height higher or lower. install the receiver and the receptacle box (protection from extreme heat is very impor- 7) The unit should never be turned off, and on tant).
  • Page 34: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS Copy of the Lighting Plate instructions ADJUSTING FLAME AUTOMATIC CONVEC- HEIGHT TION FAN OPERATION Your heater has an adjustable flame to tailor the The fan operates automatically - turn the knob look and heat output to your specific needs. It at the top right rear corner to adjust to the is adjusted by turning the flame adjustment dial desired speed.
  • Page 35: Normal Operating Sounds Of Gas Appliances

    MAINTENANCE 2) Clean glass (never when unit is hot), appli- NORMAL OPERATING CAUTION: ANY SAFETY SCREEN ance, and door with a damp cloth. Never OR GUARD REMOVED FOR SERV- SOUNDS OF use an abrasive cleaner. ICING AN APPLIANCE MUST BE GAS APPLIANCES 3) The heater is finished in a porcelain finish REPLACED PRIOR TO OPERAT-...
  • Page 36: General Vent Maintenance

    MAINTENANCE 1) Lift off the Cast Top. GENERAL VENT FAN MAINTENANCE MAINTENANCE If your fan requires maintenance or replace- ment, access to the fan is through the rear Conduct an inspection of the venting system access panel on the back of the unit. NOTE: the semi-annually.
  • Page 37: Removing And Installing Valve

    MAINTENANCE 11) Carefully lift the burner tray assembly out. 3) Disconnect gas line to stove. 4) Disconnect 3/8" NPT pipe from 90 elbow on valve. 5) Disconnect the two (2) switch wires from valve. Replacing the Fan: Reverse the above steps (1 - 4). Make sure the fan wires and the ground wire are reattached.
  • Page 38: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 942-301** Casting - Top Auto On/Off Passage 942-311** Casting - Top Grill 908-106 Decal-Rear Control Panel W842051 Gasket - Upper Air 942-321** Casting - Left Side Passage Top 942-331** Casting - Right Side 260-917...
  • Page 39 PARTS LIST BURNER & LOG ASSEMBLY Part # Description 740-574/P Valve Assembly S.I.T. - Natural Gas 740-576/P Valve Assembly S.I.T. - Propane 910-378 Valve S.I.T. - Natural Gas 904-689 #33 Orifice - N.G. 904-645 #51 Orifice - LP 910-190 Piezo Ignitor & Nut 908-672 Control Panel Decal 490-061...
  • Page 40 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 41 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 42 NOTES _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ____________________________________________________________ __________________________________________________________ ____________________________________________________________...
  • Page 43: Warranty

    At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, field modifications or upgrades will not be performed.
  • Page 44 Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date Installed: _________________________________________________________ Serial No.: _____________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

H35-lpH35

Table of Contents