Advertisement

H15 Direct Vent Gas Fireplace
WARNING:
If the information in these instructions are not
followed exactly, a fire or explosion may result
causing property damage, personal injury or loss
of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable
vapours and liquids in the vicinity of this or any
other appliance.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
Tested by:
918-219b
FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
www.hampton-fire.com
MODELS:
H15-NG Natural Gas
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch:
do not use any phone in your
building.
Immediately call your gas supplier
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your gas
supplier, call the fire department.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
Installation Manual
H15-LP Propane
This appliance may only be
installed in an aftermarket per-
manently located, manufac-
tured (USA only) or mobile
home, where not prohibited
by local codes.
This appliance is only for use
with the type of gas indicated
on the rating plate. This appli-
ance is not convertible for use
with other gases, unless a cer-
tified kit is used.
Owners &
01/09/06

Advertisement

Table of Contents
loading

Summary of Contents for HAMPTON BAY Hampton H15-NG

  • Page 1 Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-219b 01/09/06 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4...
  • Page 2: Unit Dimensions

    Congratulations! You are the owner of a state-of-the-art Hampton Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H15 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Page Page Safety Label Support Extension - Round or Square ....... 25 High Elevation ............25 Safety Label ............4 Gas Connection ............25 System Data Chart ..........25 Installation Aeration Adjustment ..........26 Gas Pipe Pressure Testing ........26 Specifications ............
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accompanies NOTE: Hampton units are constantly being each Direct Vent Freestanding Gas Stove. We improved. Check the label on the unit and if there have printed a copy of the contents here for is a difference, the label on the unit is the correct your review.
  • Page 5: Installation

    INSTALLATION 501A, and with CAN/CSA Z240-MH Mobile IMPORTANT: DUE TO HIGH TEMPERATURES, Home Standard in Canada. THE APPLIANCE SHOULD BE LO- SAVE THESE CATED OUT OF TRAFFIC AND This appliance installation must comply with the INSTRUCTIONS manufacturer's installation instructions and lo- AWAY FROM FURNITURE AND cal codes, if any.
  • Page 6: General Safety Information

    INSTALLATION 5) This appliance is Listed for Alcove installa- 9) To prevent injury, do not allow anyone who CLEARANCES TO tions, maintain minimum Alcove clearances is unfamiliar with the operation to use the COMBUSTIBLES as follows, minimum width of 32-1/2" fireplace.
  • Page 7: Locating Your Gas Stove

    INSTALLATION 4) Remove the nylon hole plug from the control OPTIONAL FAN LOCATING YOUR panel. INSTALLATION GAS STOVE 5) Install the fan speed controller onto the control panel and secure with nut and Fan Kit Contains: When selecting a location for your stove, en- washer.
  • Page 8 INSTALLATION 12) Slide fan into place and secure with the two 14) Connect fan ground wire to lug nut at base 9) Remove 2 screws from unit. screws removed in step 9. of unit. Lug Nut 10) Place grommet in rear plate through the bottom of the opening as shown below.
  • Page 9: Venting Introduction

    3) Installation of any component part not man- POSITION ufactured or approved by Simpson Dura- Vent or FPI Fireplace Products International Note: These flue pipes must not be Ltd. To set the Vent restriction as indicated in the connected to any other appliance.
  • Page 10: Exterior Vent Terminal Locations

    INSTALLATION EXTERIOR VENT TERMINAL LOCATIONS Hampton H15 Direct Vent Freestanding Gas Stove...
  • Page 11: Rigid Pipe Venting Components List

    INSTALLATION RIGID PIPE VENTING COMPONENTS LIST All Simpson Dura-Vent components are available directly from FPI. Description Simpson Dura-Vent Selkirk Amerivent Direct VentGS Direct-Temp Direct Vent 6" Pipe Length, Galvanized 4DT-6 6" Pipe Length, Black 908B 4DT-6B 7" Pipe Length, Galvanized 7"...
  • Page 12: Rigid Pipe Venting Systems

    The FPI AstroCap and FPI Riser Vent terminal is certified for installations using FPI venting systems as well as Simpson Dura-Vent®, Direct Vent GS, American Metal Products, Ameri Vent Direct vent and Selkirk Direct-Temp. FPI , and FPI AstroCap are the proprietary trademarks of FPI Fireplace Products International Ltd.
  • Page 13: Horizontal Venting With Two Elbows

    INSTALLATION Horizontal Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option H + H1 With these options, maxi- 1' Min. 3' Max. mum total pipe length is 30 feet with minimum of 6 feet 2' Min. 4' Max.
  • Page 14: Veritcal Venting Wtih Two Elbows

    INSTALLATION Vertical Venting with Two (2) 90 Elbows One 90 elbow = Two 45 elbows. Option V V + V1 With these options, max. total pipe length is 30 feet with min. 1' Min. 4' Max. 2' Min. of 6 feet total vertical and max. 2' Min.
  • Page 15: Venting Arrangements - Horizontal Terminations

    45 elbow off the unit. Restrictor position "A". 12" max. w/AstroCap & Simpson Duravent Horizontal Square Termination Cap. 24" max. w/FPI Riser & Simpson Duravent Snorkel Termination Cap. Hampton H15 Direct Vent Freestanding Gas Stove...
  • Page 16: Vertical Termination With Co-Linear Flex System

    INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM Masonry chimneys may take various contours which the flexible liner will accommodate. THE APPLIANCE MUST NOT BE However, keep the flexible liner as straight as possible , avoid unnecessary bending. CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL The Air Intake pipe must be attached to the inlet air collar of the termination cap.
  • Page 17: Horizontal Termination Kit

    INSTALLATION DV STOVE HORIZONTAL VENT KIT DV 2 ft. Stove Vent Kit (Part # 946-116) and DV 4 ft. Stove Vent Kit (946-216) includes all the parts needed to install the H15 Direct Vent unit with up & out horizontal and vertical vent dimensions. For installations that require longer vertical and/or horizontal vents use the Dura-Vent system as shown on page 16.
  • Page 18 INSTALLATION 13) Secure the 4" dia. flex liner with adapter onto the stove collar. Put a bead of Mill-Pac around the appliance adapter and secure with 3 screws (#8 x 1/2, stainless steel). 14) Attach the 45 elbow onto the starter collar by sealing with Mill-Pac and/or high tem- perature silicone and securing with 3 of the #8 x 1/2"...
  • Page 19: Residential And Manufactured Homes / Mobile Homes Minimum Horizontal Termination Installations

    INSTALLATION RESIDENTIAL AND MANUFACTURED HOMES / MOBILE HOMES MINIMUM HORIZONTAL TERMINATION INSTALLATIONS You will require the following components with your new Hampton Direct Vent Freestanding Gas Planning Your venting Installation Stove. Please review your product to make sure you have everything you need. In the event that you are missing any part, contact your dealer.
  • Page 20: Dura-Vent Termination Kits

    Terminal 1 Horiz. Sq. Term. Cap Part# 640-530/P The FPI AstroCap is certified for installations using FPI venting systems as well as Simpson Dura-Vent® and Direct Vent GS. The FPI AstroCap is a proprietary trademark of FPI Fireplace Products International Ltd.
  • Page 21: Dura-Vent Venting Components Parts List

    INSTALLATION Parts not supplied by Dura-Vent the 9-1/2 round hole in the exterior wall DURA-VENT VENTING 946-506/P Vent Guard (Optional) AstroCap where the vent will be terminated. If the COMPONENTS wall being penetrated is constructed of 946-208/P Vent Guard (Optional) Riser Vent Terminal non-combustible material, i.e.
  • Page 22: Termination

    INSTALLATION NOTE: For Snorkel terminations in ABOVE 7) Install the Backing Plate into the wall pene- 8) Slide the decorative wall thimble up to the grade installations, follow national tration heat shield and attach using 4 wall surface being careful not to scratch or local code requirements.
  • Page 23 INSTALLATION 7) Ensure vent is vertical and secure the base the venting system. You may wish to relo- cate the appliance or to offset, as shown in of the flashing to the roof with roofing rails, diagram 8 to avoid cutting load bearing slide storm collar over the pipe section and seal with a mastic.
  • Page 24: Converting A Class-A Metal Chimney Or Masonry Chimney To A Direct Vent System

    INSTALLATION 4) Pass the flex pipe down through the center CONVERTING A CLASS- Approved for US Installations Only of the chimney system, and center the The use of an existing chimney as an air A METAL CHIMNEY OR adaptor on the top of the chimney pipe. Drill intake is not covered under the ANSI four 1/8"...
  • Page 25: Cathedral Ceiling Installations

    INSTALLATION half of the flashing should be under the CATHEDRAL CEILINGS IMPORTANT: ALWAYS CHECK FOR shingles. GAS LEAKS WITH A SOAP AND WATER SOLUTION OR GAS LEAK Round Support (RDS) & 4) Assemble the desired lengths of Black Pipe and Elbows necessary to reach from the DETECTOR.
  • Page 26: Aeration Adjustment

    2) Loosen the "IN" and/or "OUT" pressure tap(s), turning counterclockwise with a 1/8" wide Note: Aeration Adjustment should only flat screwdriver. be performed by an authorized FPI Installer at the time of installation 3) Attach manometer to "IN" and/or "OUT" pres- or service.
  • Page 27: Conversion To Propane

    INSTALLATION CONVERSION FROM NATURAL GAS TO PROPANE THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !! Conversion Kit #380-969 Contains: 6) Pull off the pilot cap to expose the pilot 13) Check for gas leaks.
  • Page 28: Log Set Installation

    INSTALLATION LOG SET INSTALLATION Read the instructions below carefully and refer to the dia- 6) Place the rear log on the 2 rear log locating pins on the rear of the grams. If the logs are broken do not use the unit until they are burner with the flat side to the back.
  • Page 29 INSTALLATION 8) Take the embers and place on the burner in the space between the 9) Place the center cross log on the locating pin in the top of the rear 2 front logs. Do not put embers on the burner in the area between log and position as shown below.
  • Page 30: Optional Wall Thermostat

    INSTALLATION OPTIONAL REMOTE FINAL CHECK OPTIONAL WALL CONTROL THERMOSTAT Before leaving this unit with the customer, the installer must ensure that the appliance is firing Use the Hampton Remote Control Kit approved correctly. This includes: A wall thermostat may be installed if desired. for this unit.
  • Page 31: Wiring Diagram

    INSTALLATION WIRING DIAGRAM - H15-NG & H15-LP Caution: Ensure that the wires do If any of the original wires as supplied with the CAUTION: Label all wires prior to appliance must be replaced, it must be replaced not touch any hot surfaces and are disconnection when servicing con- with CSA type SEW (200 C) or its equivalent.
  • Page 32: Operating Instructions

    OPERATING INSTRUCTIONS OPERATING 1) Turn stove OFF using the Burner "ON/OFF" facturing. Smoke detectors in the house may go switch remote or thermostat. Switches off at this time. Open a few windows to ven- INSTRUCTIONS are located at the top right hand corner tilate the room for a couple of hours.
  • Page 33: Copy Of Lighting Plate Instructions

    OPERATING INSTRUCTIONS COPY OF THE LIGHTING PLATE INSTRUCTIONS Hampton H15 Direct Vent Freestanding Gas Stove...
  • Page 34: Normal Operating Sounds Of Gas Appliances

    MAINTENANCE 2) Clean glass (never when unit is hot), appli- NORMAL OPERATING CAUTION: ANY SAFETY SCREEN ance, and door with a damp cloth. Never OR GUARD REMOVED FOR SERV- SOUNDS OF use an abrasive cleaner. ICING AN APPLIANCE MUST BE GAS APPLIANCES 3) The heater is finished in a porcelain finish REPLACED PRIOR TO OPERAT-...
  • Page 35: Log Installation

    MAINTENANCE GENERAL VENT GLASS FAN MAINTENANCE MAINTENANCE REPLACEMENT If your fan requires maintenance or replace- ment, access to the fan is through the rear Conduct an inspection of the venting system Your stove is supplied with high temperature, access panel on the back of the unit. semi-annually.
  • Page 36: Removing And Installing Valve

    MAINTENANCE 9) Remove burner by removing the 2 screws 12) To remove the valve, remove the 4 screws REMOVING VALVE on each side, slide the burner to the left and (2 per bracket) that hold the valve to the then lift the burner tray out. valve bracket assembly.
  • Page 37: Parts List

    PARTS LIST MAIN ASSEMBLY Part # Description Part # Description Part # Description 380-012 Rear Panel 942-601** Casting - Top 380-011 Restrictor 910-330 Fan Speed Control (120V) 942-621** Casting - Side & Leg 948-255 Latch Ojop W/J-Hook 904-569 Knob - Fan Speed Control 942-611** Casting - Front 940-338/P Replacement Glass...
  • Page 38 PARTS LIST BURNER & LOG ASSEMBLY Part # Description 380-574/P Valve/Pilot Assembly - S.I.T. - NG 910-378 Valve S.I.T. - Natural Gas 904-434 #47 Orifice - NG 910-190 Piezo Ignitor & Nut 908-672 Control Panel Decal 490-061 Switch Plate 936-170 Orifice Gasket 910-038 Pilot Assy-S.I.T.
  • Page 39: Warranty

    At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. as products evolve, field modifications or upgrades will not be performed.
  • Page 40 Dealer Name & Address: ________________________________________________ ______________________________________________________________________ Installer: ______________________________________________________________ Phone #: ______________________________________________________________ Date Installed: _________________________________________________________ Serial No.: _____________________________________________________________ Hampton is a trademark of FPI Fireplace Products International Ltd. © Copyright 2005, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

H15-lpH15

Table of Contents