Greenfire GF55 Owner's Manual

Freestanding and fireplace insert pellet stove
Hide thumbs Also See for Greenfire GF55:

Advertisement

WARNING:
Improper installation, adjustment, alteration,
s e r v i c e
o r
m a i n t e n a n c e
injury, property damage, or loss of life.
Refer to this manual. For assistance or
additional information consult an authorized
installer or service agency.
Tested by:
GF55-079
FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4
GF55 & GFI55
Freestanding and Fireplace
c a n
c a u s e
IMPORTANT: SAVE THESE INSTRUCTIONS
OWNER'S MANUAL
Insert Pellet Stove
FOR YOUR SAFETY:
Do not store or use gasoline or other fl ammable
vapours and liquids in the vicinity of this or any other
appliance.
Installation and service must be performed by an
authorized installer or service agency.
10/26/09

Advertisement

Table of Contents
loading

Summary of Contents for Greenfire Greenfire GF55

  • Page 1 Installation and service must be performed by an additional information consult an authorized authorized installer or service agency. installer or service agency. Tested by: IMPORTANT: SAVE THESE INSTRUCTIONS GF55-079 FPI FIREPLACE PRODUCTS INTERNATIONAL, LTD. 6988 Venture St., Delta, BC, Canada V4G 1H4 10/26/09...
  • Page 2 Congratulations! You are the owner of a state-of-the-art Pellet Stove. Thank-you for purchasing a FPI FIREPLACE PRODUCT. The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product that are not covered in this manual, please contact the GREENFIRE DEALER in your area.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS SAFETY LABEL MAINTENANCE Copy of Serial No. Decal ..........4 Routine Cleaning & Maintenance ........10 Opening the Door ...........10 Burn Pot & Liner .............10 INSTALLATION Door Glass Cleaning ..........10 Ash Pan & Door Gaskets ........10 Safety Warnings & Recommendations ......5 Ash Pan ..............
  • Page 4: Safety Label

    SAFETY LABEL This is a copy of the label that accom- panies each GF55 & GFI55. We have printed a copy of the contents here for your reference. On the GF55 the safety label is located on the underside of the hopper lid. On the GFI55 the safety label is located on the hopper cover behind the top faceplate.
  • Page 5: Installation

    ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical SINCE FPI HAS NO CONTROL OVER THE INSTALLATION OF YOUR cord should be connected to a standard 115 volts (4.6 Amps), 60 hertz STOVE, FPI GRANTS NO WARRANTY IMPLIED OR STATED FOR THE electrical outlet.
  • Page 6: Important Safety Information

    This may require an adjustment to the slider damper setting or to the auger feed trim setting on low. Since FPI has no control over the quality of pellets that you use, we assume no liability for negative results in selection of wood pellets.
  • Page 7: Operating Instructions

    OPERATING INSTRUCTIONS CONTROL BOARD FUNCTIONS 1. AUGER LIGHT: This green light will fl ash in conjunction with the auger pulse. 2. MODE LIGHT: Responsible for signaling the state of the control board. When the light AUGER is fl ashing the stove is in an automatic start mode or the thermostat has control of the unit.
  • Page 8: Operating Your Pellet Stove

    OPERATING INSTRUCTIONS OPERATING YOUR PELLET STOVE PRE-BURN INSTRUCTIONS: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit. Note: The thermostat mode can be changed during normal operation. DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
  • Page 9: Slider / Damper Set-Up

    OPERATING INSTRUCTIONS SLIDER / DAMPER SET-UP THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION. A Qualified Service Technician or Installer must set the Slider Damper. This is used to regulate the airflow through the pellet stove. The slider damper knob is located on the left cab side (see Figure 7).
  • Page 10: Maintenance

    MAINTENANCE ROUTINE CLEANING & MAINTENANCE The following list of components should be inspected and maintained If after long periods of burning, the fi re continually builds up and overfl ows routinely to ensure that the appliance is operating at its optimum and the burn pot or there is a build up of clinkers, this is an indication that giving you excellent heat value: the pellet fuel quality is poor or the stove may need cleaning.
  • Page 11: Ash Pan

    MAINTENANCE ASH PAN FRESH AIR INTAKE (weekly) (season) The ash pan is located under the burner. Always dispose of the ashes into Inspect periodically to be sure that the intake pipe is not clogged with any a metal container (never use cardboard, plastic or wood containers) stored foreign materials.
  • Page 12: Exhaust Passages

    MAINTENANCE EXHAUST PASSAGES POST SEASON CLEAN-UP (season) Once you are fi nished using the pellet appliance for the season, unplug the stove for added electrical protection. It is very important that the stove Removal of the firebox backing for bi-annual cleaning (refer to be cleaned and serviced as stated above.
  • Page 13: Warranty

    WARRANTY FPI is the manufacturer of the Greenfi re line of heating products. At FPI, our commitment to the highest level of quality and customer service is the most important thing we do. Each Greenfi re stove is built on a tradition of using only the fi nest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser.
  • Page 14: Exclusions And Limitations

    9. This warranty does not cover products made or provided by other manufacturers and used in conjunction with the operation of this stove without prior authorization from FPI The use of such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Greenfi...
  • Page 15 Labour rates are set per component and as such total labour costs may not be covered. 27. FPI is not liable for freight or labour on any stove replaced in-fi eld and is not liable for travel costs for service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service charges required by the Authorized Dealer.
  • Page 16 Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ______________________________________________________ Serial No.: __________________________________________________________ Greenfi re is a trademark of FPI Fireplace Products International Ltd. © Copyright 2009, FPI Fireplace Products International Ltd. All rights reserved. Printed in Canada...

This manual is also suitable for:

Greenfire gfi55

Table of Contents