Leveling; Electrical Connections - Vulcan-Hart VEC3018 ML-126198 Installation & Operation Manual

Vec series electric conveyor ovens
Table of Contents

Advertisement

Installing Stacked Ovens
1. Stack ovens after basic oven is installed.
2. Lift top oven and place it on top of bottom oven.
3. No fasteners are required; the weight of the oven will keep it in place.

LEVELING

Casters for this oven are of the non-adjustable type. For best results oven should be installed on a level
floor.

ELECTRICAL CONNECTIONS

WARNING:
ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE
APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION)
AND/OR OTHER LOCAL ELECTRICAL CODES.
WARNING:
DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE
DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT.
1. Remove wiring compartment cover from the right rear of the oven.
2. Run power supply cord through the conduit fitting.
3. Connect wires at the terminal block.
4. Follow the appropriate wiring diagram that is included with this manual when making connections
at the electric supply lines.
5. Replace wiring compartment cover.
6. Turn power supply ON.
Electrical Data
Oven Model
VEC3018
VEC4018
VEC3624
VEC3632
VEC4824
VEC4832
VEC6024
VEC6032
Total Kw
208V
10
28
15
42
15
42
30
83
30
83
45
125
45
125
60
166
60
166
Nominal Amps Per Line Wire
3 Phase
240V
480V
24
12
36
18
36
18
72
36
72
36
108
54
108
54
144
72
144
72
— 5 —
1 Phase
208V
240V
48
42
72
63
72
63
144
125
144
125
216
188
216
188
288
250
288
250