Monarch Instrument Division of Monarch International Inc. 15 Columbia Drive, Amherst NH 03031 USA declares under Monarch’s sole responsibility that the product: SLS - Smart Laser Sensor to which this declaration relates is in conformity with the following directives and...
Page 2
SAFEGUARDS AND PRECAUTIONS Examples: 1234.56<cr> 123456.<cr> _ _ _ _0.0<cr> ( _ = space character) 10.0 CHARGING Slide the Power switch (8) to the Off/Charge position and plug in the WARNING - This product emits a visible beam of laser charger.
To change the setting, move the Polarity switch (5) to the left (positive TABLE OF CONTENTS TABLE OF CONTENTS pulse) for a white target or to the right (negative pulse) for a black target. Turn the Sensitivity Adjust knob (7) to Max. Press and hold the Learn/ Gain button (6) until the Auto/Gain LED (3) blinks.
1.0 SMART LASER SENSOR SPECIFICATIONS In many applications, this is all Number of blinks Gain that is needed. In cases where the 1 Strong Signal Laser Specifications: target is marginal, the user may need to manually adjust the Classification: Class 3R (per IEC 60825-1 Ed 1.2 2001-8) sensitivity after trying the Auto Complies with FDA performance standards for laser products except for mode.
Page 5
6.0 OPERATION Max RPM: 500,000 RPM Min. Trigger Duration: 10 sec Note: Refer to Figure 3 for switch and button locations. Indicators: LEDs for On Target, Laser On, Auto/Gain, Power/Charge Turn the unit on by moving the Power switch (8) to the On position. The unit may be operated from the internal batteries and/or the charger/power Modes: Normal (manual) or Auto, and charging...
Page 6
Pulse Output (continued): The output socket on the unit has the following connections: Polarity: Positive or Negative pulse (switch selectable) Description Wire Color (of cable) RS232: Transmit Out – ASCII value of RPM (Accuracy ± RS232 Receive (input to 0.002% of reading) sensor) Common Orange...
If after completing step 4.4, the On Target LED (1) blinks Weight: 10.6 oz (300.5 grams) excluding cable and charger erratically or not at all, rotate the Sensitivity Adjust knob (7) Compliance: CE 93/68/EEC EMC directive (EN 61326:2001) slowly from 1 to 9 until the LED blinks regularly or is on solid. IEC 61010-1 2001, IEC 60825-1 2001, CFR 1040.10 and If after completing steps 4.1-4.5, the On Target LED (1) blinks 1040.11 except for deviations pursuant to Laser Notice No.
3.0 INDICATORS AND SWITCHES Charge position: Blinks RED when fast charging for very low batteries. Blinks AMBER when slow charging. Steady AMBER when the batteries are fully charged. Polarity switch Selects either a positive or negative output pulse. Learn/Gain button In Auto Mode: Press and hold until the On Target LED blinks regularly or is on solid.