set cdp hold-time

Use this command to set the hold time value for CDP discovery protocol configuration messages.
Syntax
set cdp hold-time hold-time
Parameters
hold‐time
Defaults
None.
Mode
Switch command, read‐write.
Example
This example shows how to set CDP hold time to 60 seconds:
D2(su)->set cdp hold-time 60

clear cdp

Use this command to reset CDP discovery protocol settings to defaults. 
Syntax
clear cdp {[state] [port-state port-string] [interval] [hold-time] [auth-code]}
Parameters
state
port‐state port‐string
interval
hold‐time
auth‐code
Defaults
At least one optional parameter must be entered.
Mode
Switch command, read‐write.
Example
This example shows how to reset the CDP state to auto‐enabled:
D2(su)->clear cdp state
Specifies the hold time value for CDP messages in seconds.Valid values are 
from 15 to 600.
(Optional) Resets the global CDP state to auto‐enabled.
(Optional) Resets the port state on specific port(s) to auto‐enabled. 
(Optional) Resets the message frequency interval to 60 seconds.
(Optional) Resets the hold time value to 180 seconds.
(Optional) Resets the authentication code to 16 bytes of 00 (00‐00‐00‐
00‐00‐00‐00‐00).
set cdp hold-time
D-Series CLI Reference 3-5