Set Logging Server - Enterasys D2 D2G124-12P Cli Reference Manual

D-series ethernet switches
Table of Contents

Advertisement

set logging server

Use this command to configure a Syslog server.
Syntax
set logging server index [ip-addr ip-addr] [facility facility] [severity severity]
[descr descr] [port port] [state {enable | disable}]
Parameters
index
ip‐addr ip‐addr
facility facility
severity severity
descr descr
port port
state enable | 
disable
Defaults
If ip‐addr is not specified, an entry in the Syslog server table will be created with the specified 
index number and a message will display indicating that no IP address has been assigned.
If not specified, facility, severity and port will be set to defaults configured with the set logging 
default command ("set logging default" on page 12‐5).
If state is not specified, the server will not be enabled or disabled.
Mode
Switch command, read‐write.
Example
This command shows how to enable a Syslog server configuration for index 1, IP address 
134.141.89.113, facility local4, severity level 3 on port 514:
D2(su)->set logging server 1 ip-addr 134.141.89.113 facility local4 severity 3
port 514 state enable
Specifies the server table index number for this server. Valid values are 1 ‐ 
8.
(Optional) Specifies the Syslog message server's IP address.
(Optional) Specifies the server's facility name. Valid values are: local0 to 
local7.
(Optional) Specifies the severity level at which the server will log 
messages. Valid values and corresponding levels are:
1 — emergencies (system is unusable)
2 — alerts (immediate action required)
3 — critical conditions
4 — error conditions
5 — warning conditions
6 — notifications (significant conditions)
7 — informational messages
8 — debugging messages
(Optional) Specifies a textual string description of this facility/server.
(Optional) Specifies the default UDP port the client uses to send to the 
server.
(Optional) Enables or disables this facility/server configuration.
set logging server