Sign in today to find solutions:

Don't have an account? Sign up

England's Stove Works PELLET STOVES Installation And Operation Manual

Englander stoves pellet stoves units installation & operation manual manual models 25-pdv 55-shp22 55-trp22 25-pdve 55-shp22e 55-trp22e.

 
INSTALLATION & OPERATION MANUAL
MODEL NUMBERS:
Thank you for purchasing this product from a fine line of heating equipment.
We wish you many years of safe heating pleasure with your new heating appliance.
IMPORTANT: IF YOU HAVE A PROBLEM WITH THIS UNIT DO NOT RETURN IT TO
THE DEALER. CONTACT TECHNICAL SUPPORT @ 1-800-245-6489.
These freestanding pellet units are approved for mobile home or doublewide installation with
outside combustion air hook-up. See "Flue System" section of manual.
Mobile home installation should be in accordance with the Manufactured Home and Safety
CAUTION: The structural integrity of the mobile home floor, wall and ceiling/roof must
Please Note the Following Precautionary Statements:
NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT.
England's Stove Works highly recommends the use of smoke detectors and
Carbon Monoxide detectors with any hearth product, including this unit. Follow all
manufacturer's instructions when using smoke or Carbon Monoxide detectors.
CAUTION: Please read this entire manual before installation and use of this pellet
fuel burning room heater.
Keep children, furniture, fixtures, and all combustible materials away
from any heating appliance. Refer to this owner's manual for all
clearances to combustible materials.
WARNING: USE OF OUTSIDE AIR IS MANDATORY WITH THIS UNIT.
DO NOT OPERATE UNIT WITH HOPPER OPEN. LID MUST BE SHUT AND TIGHTLY SECURED.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE,
BODILY INJURY OR EVEN DEATH. FOR YOUR SAFETY AND PROTECTION, FOLLOW ALL
THE INSTALLATION INSTRUCTIONS. CONTACT YOUR LOCAL BUILDING OR FIRE
OFFICIALS FOR RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS
(INCLUDING PERMITS) IN YOUR AREA.
25-PDV
25-PDVE
Save These Instructions.
Mobile Home Use:
Standard (HUD), CFR 3280, Part 24.
WARNING: Do Not Install in Sleeping Room
be maintained.
DO NOT OPERATE WITH DOOR OPEN
SAFETY NOTICE
Questions? Need Parts or Options?
55-SHP22
55-TRP22
55-SHP22E
55-TRP22E
www.englanderstoves.com
Rev. 1/07

Summary of Contents

  • Page 1

    CAUTION: The structural integrity of the mobile home floor, wall and ceiling/roof must Please Note the Following Precautionary Statements: NOTE: WE DO NOT RECOMMEND PELLET STOVES AS YOUR ONLY SOURCE OF HEAT. England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide detectors with any hearth product, including this unit.

  • Page 2

    A letter from our Technical Support department: Thank you for purchasing this fine product from England’s Stove Works! England's Stove Works was started, and is still owned by, a family that believes strongly in a "Do It Yourself" spirit – that’s one reason you found this product at your favorite “Do It Yourself”...

  • Page 3

    Central Furnace. If you install your stove in the same room as the Cold Air Return from your home’s Central Furnace, you must place your stove at least 20 feet (20’) from the Cold Air Return. We recommend you open an outside window slightly, and never close the door that leads from this room to the rest of your home.

  • Page 4

    Read and comply with the instructions in this manual. This unit should be tested (dry run) before loading pellets for 20 minutes. The stove should automatically shut itself off after the 20-minute dry run.

  • Page 5

    If you manually start your unit, recommended fire starter materials are: Wax-impregnated wood chips, cardboard cubes or firestarter chips designed for pellet stoves (see section on Manually Starting Unit). Follow any manufacturer’s directions for these products, and NEVER place any firestarter on any hot surface or hot coals.

  • Page 6

    Occasionally in shipping, the impingement (baffle) plate may shift out of its proper position. If this is the case with your stove, follow these instructions to return the plate to its proper position. Remove the plate from the stove, holding the plate by its tab handle, with the cutout notch facing upwards.

  • Page 7

    If you live in an area that has heavy snowfall, it is recommended the installation be taller than three feet (3’) to get above the snowdrift line. The same type installation can be used if your stove is below ground level by adding the clean- out section and vertical pipe inside until ground level is reached.

  • Page 8

    Connect a three inch (3”) tee with clean-out to the pipe adapter -- seal this with high temperature stove cement, then extend your pipe to the installed reducer at the thimble. If the thimble is in the ceiling, the pipe will go straight up, but if the thimble is in the wall another 90-degree elbow will be required to make the connection.

  • Page 9

    The protection should be U.L. approved or equal, and should be large enough to provide a minimum of six inches (6”) behind and on both sides of the stove. The clearance in front of the stove should be at least six inches (6”). This freestanding pellet unit will need a minimum 36”...

  • Page 10

    Exhaust Blower could put out the fire). Recommended fire starter materials: Wax-impregnated wood chips, cardboard cubes or firestarter chips designed for pellet stoves. Follow any manufacturer’s directions for these products, and NEVER place any firestarter on any hot surface or hot coals. Never use gasoline, lantern fuel, kerosene, charcoal lighter fluid, diesel fuel or any other flammable liquid to start the fire.

  • Page 11

    The red light will then shut off and the entire stove will be shut down. The hotter the unit is operating, the longer it will take for the stove to complete the Shut-Down cycle.

  • Page 12

    NOTE: Remember: 1) It is very important for the unit to be vented properly (see instructions on Outside Air), as the natural draft is needed to clear the smoke from the stove. 2) Do not open the hopper lid (or the unit’s door). This may cause fire to burn in the hopper.

  • Page 13

    Press the “OFF” touch pad and allow the stove to burn for five (5) minutes prior to opening the door. A long-handled screwdriver or long-handled putty knife can be used to scrape off any build-up or crust in the burn pot area.

  • Page 14

    The stove and the flue system should be given a complete cleaning at the end of the heating season.

  • Page 15

    WARNING: To perform any maintenance inside the rear of the unit, the stove must be out (no fire), cooled down and unplugged. Electrical shock can occur if the unit is not unplugged from power.

  • Page 16

    The Convection (room air) Blower (Part # PU-4C447) is located on the left side of the unit and can be removed by disconnecting the power leads and removing the four mounting screws. Once this is done, the blower will slide out of the stove. This procedure can be reversed to install a new blower.

  • Page 17

    This part can be removed from the unit by loosening the two outside screws and pulling the board back to the inside of the stove. The rear access panel should be removed prior to removing the control board. A 6-amp “quick-blow” fuse is used on this Control Board.

  • Page 18

    Consult a professional installer and/or call Technical Support if you have any questions. IMPORTANT SAFETY NOTE: white), the stove is over-fired. This condition could cause a house or chimney fire. Do not operate your unit too hot, or over-firing may result.

  • Page 19

    Adjusting your Hopper Lid Latches The seals around the top of the pellet hopper are important to safe an efficient operation of the unit. The latches installed on these units are designed to pull the hopper lid tight against this seal. Over the course of operation as these seals “wear in”...

  • Page 20

    The spring clip will hold well if it is placed on the top edge of the trim before placing the trim in the window of the stove. Place the top edge with the clip into the window opening, then push the bottom edge of the trim flush with the window.

  • Page 21

    REPLACEMENT PARTS, ACCESSORIES AND OPTIONS AC-GGK Glass Gasket Kit (gasket only, no glass) AC-DGKC Door Gasket Kit (#2 on diagram) AC-114 Brass Louvers (#26 on diagram) (2001 and later Models; for earlier models call 800-245-6489 for AC-112 louvers) AC-114BN Nickel Louvers (#26 on diagram) AC-G9 9”...

  • Page 22

    Pellet Stove – Exploded View Diagram Illustration 6 Dimensions of your pellet unit: 28 ½”W x 30”H x 28 ½”D 375 lbs. (Approx. 13 ½” height from floor to center of exhaust)

  • Page 23

    1. Remove auger and clean 2. Re-align auger 1. Check blower for material 2. Check impeller blower screw 1. Check stove connection 2. Check settings; always start unit on “5” to “9”setting 3. Check igniter for buildup 1. Check for flue blockage (nests, rodents, excess soot, etc.)

  • Page 24

    Have this information on hand if you phone the factory or your dealer regarding this product. Retain for your files: Model Number __________________________ Date of Purchase ________________________ Date of Manufacture _____________________ LIMITED 5 YEAR WARRANTY FROM THE DATE OF PURCHASE TO THE ORIGINAL OWNER The manufacturer extends the following warranties: Five Year Period: 1.

  • Page 25

    WARRANTY REGISTRATION for England’s Stove Works Purchased by (Name) ______________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ Telephone _______________________________________________________ Email Address ___________________________________________________ Purchased From (Dealer) ___________________________________________ Address _________________________________________________________ City ________________________ State __________ Zip _________________ (Please be sure to refer to sticker on back of manual or box to complete this section)