ECS DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 Installation And Owner's Manual

The tahoe direct vent zero clearance gas fireplace heater

Advertisement

Quick Links

The Tahoe Direct Vent Zero Clearance Gas
Fireplace Heater
Installer:
Leave this manual with the appliance.
Consumer: Retain this manual for future reference.
WARNING: If the information in these instruc-
tions are not followed exactly, a fire or explosion
may result causing property damage, personal
injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not
use any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
If you cannot reach your gas supplier, call
the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
23552-1-0607

INSTALLATION INSTRUCTIONS

OWNER'S MANUAL
GAS-FIRED
AND
DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
MILLIVOLT
DVD32FP3(0,1,2,3)(N,P)-1
DVD36FP3(0,1,2,3)(N,P)-1
DVD42FP3(0,1,2,3)(N,P)-1
DVD48FP3(0,1,2,3)(N,P)-1
DIRECT IGNITION
DVD32FP5(0,1,2,3)N-2
DVD36FP5(0,1,2,3)N-2
DVD42FP5(0,1,2,3)N-2
DVD48FP5(0,1,2,3)N-2
EFFECTIVE DATE
JUNE 2007
UL FILE NO. MH30033
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA only)
or mobile home, where not prohibited by state or local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certified
kit is used.
WARNING: If not installed, operated and
maintained in accordance with the manufacturer's in-
structions, this product could expose you to substances
in fuel or from fuel combustion which can cause death
or serious illness.
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for ECS DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2

  • Page 1: Installation Instructions

    The Tahoe Direct Vent Zero Clearance Gas Fireplace Heater Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference. WARNING: If the information in these instruc- tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Section Page Important Safety Information ... 3 Safety Information for Users of LP Gas ... 4 Requirements for Massachusetts ... 5 Introduction ... 6 Specifications ... 7 Fireplace Dimensions ... 7 Clearances ... 8 Locating Fireplace ... 8 Gas Supply ...
  • Page 3: Important Safety Information

    IMPORTANT SAFETY INFORMATION Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly. DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED • If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.
  • Page 4: Safety Information For Users Of Lp Gas

    SAFETY INFORMATION FOR USERS OF LP GAS Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precautions which can protect both you and your family from an accident.
  • Page 5: Requirements For Massachusetts

    REQUIREMENTS FOR MASSACHUSETTS For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 6: Introduction

    • Installation of any damaged fireplace or vent system component. • Modification of the fireplace or direct vent system. • Installation other than as instructed by Empire Comfort Systems, Inc. • Improper positioning of the logs, glass door or decorative rock.
  • Page 7: Specifications

    Input BTU/Hr Maximum BTU/Hr Minimum (millivolt only) KWH (Maximum) (Minimum) NAT. Orifice Air Shutter Opening Orifice Air Shutter Opening Height without standoff Width Depth Gas Inlet Shutoff Valve (Pipe) Venting Options DVVK-4TS Top vent kit (HORZ.) - 4½" to 6" (114.3mm to 152mm) wall thickness DVVK-4T Top vent kit (horz.) - 8"...
  • Page 8: Clearances

    Clearance to Combustibles Back 0" (0 mm) Side 0" (0 mm) Floor 0" (0 mm) Top Stand-off 0" (0 mm) Top Framing Edge 3" (76 mm) Figure 2 Combustible Material No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace.
  • Page 9: Gas Supply

    he gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code. Recommended Gas Pipe Diameter Pipe Length Schedule 40 Pipe Inside Diameter Nat.
  • Page 10: Rear Vent Conversion/Vent Systems

    VERTICAL VENTING Note : It is recommended that the flue cover plate tab be pulled outward prior to removal. This will ensure that the plate is not accidentally dropped inside the rear air chamber. FLUE COVER PLATE (See note above) INLET VENT COVER PLATE Converting flue take-off to rear venting...
  • Page 11: Installation

    Framing and Finishing 1. Choose unit location. 2. Frame in fireplace with a header across the top. It is important to allow for finished face when setting the depth of the frame. 3. Attach fireplace to frame using adjustable frame. Preset depth to suit facing material (adjustable to 1/2", 5/8"...
  • Page 12 Flush Mount Mantel Installation (Figure 10) The fireplace must extend 3/4" beyond finished wall surface when using a flush mount mantel. Refer to Figure 10 to locate nailing flanges on fireplace sides. Mark and drill two (2) 1/8" holes into fireplace side to mount each nailing flange.
  • Page 13 Flush Wall Installation FINISHED WALL 3! OF NON-COMBUSTIBLE MATERIAL FRONT TRIM OR NON- COMBUSTIBLE MA TERIAL (INSTALLA TION IS OPTIONAL) JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300° F, 149° C SEALANT MATERIAL (SEALANT IS OPTIONAL) Figure 12 Combustible Surround Installation COMBUSTIBLE SURROUND FINISHED WALL 2 X 4...
  • Page 14 HORIZONTAL ONLY, STRAIGHT OUT THE BACK " A" PIPE LENGTH "A" "B" 6" 5 1/8" to 6 1/2" (130mm to 165mm) 9" 8 1/8" to 9 1/2" (206mm to 241mm) 12" 11 1/8" to 12 1/2" (283mm to 317mm) Figure 15 VERTICAL, 90°...
  • Page 15: Venting Fireplace-Top Vent

    VENTING FIREPLACE - TOP To Use the Vent Graph (Figure 19) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line.
  • Page 16 VENTING FIREPLACE - TOP (continued) Below Grade Installation When it is not possible to meet the required vent terminal clearances of 12" (305mm) above grade level, a snorkel kit is recommended. It allows installation depth down to 7" (178mm) below grade level. The 7"...
  • Page 17 Figure 23 MINIMUM HOLE LOCATION DIMENSIONS FOR THROUGH THE WALL HORIZONTAL INSTALLATIONS WITH 90 DEGREE ELBOW OFF TOP OF FIREPLACE FIREPLACE HARD ELBOW DIMENSIONS SERIES "A" "B" DVD32FP 41-1/2" 4" (1054mm) (102mm) DVD36FP 41-1/2" 4" (1054mm) (102mm) DVD42FP 43-1/2" 4" (1105mm) (102mm) DVD48FP...
  • Page 18 EXAMPLES - TOP VENT RUN 24” 24” MINIMUM CLEARANCE TO COMBUSTIBLES Figure 27 Figure 26 Figure 28 Page 18 23552-1-0607...
  • Page 19: Venting Fireplace-Rear Vent

    VENTING FIREPLACE - REAR To Use the Vent Graph (Figure 29) 1. Determine the height of the center of the horizontal vent pipe. Using this dimension on the Sidewall Vent Graph, locate the point it intersects with the slanted graph line. 2.
  • Page 20 EXAMPLES - REAR VENT RUN Figure 30 Model DVD32 DVD36 DVD42 DVD48 Figure 31 Page 20 Maximum Pipe Length H1 24" 24" 18" Model Maximum Pipe Length H1 DVD32 24" DVD36 24" DVD42 24" DVD48 6" Figure 32 Figure 33 23552-1-0607...
  • Page 21: Termination Clearances

    TERMINATION CLEARANCES Termination clearance for buildings with combustible and noncombustible exteriors. Figure 34 Vertical Sidewall Installations Important! Minimum clearance between vent pipes and combustible materials is three (3") (76mm) on top, and (1") (25mm) on bottom and sides. Important! When vent termination exits through foundation less than 20" below siding outcrop, the vent pipe must flush up with the siding.
  • Page 22: Vent Clearances

    *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum] clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances < 100,000 BTU/Hr (30kW) clearance to permanently closed window [minimum 12 inches (30cm) recommended to prevent condensation on window] vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 24 inches (60 cm) from...
  • Page 23: Vent System Identification

    THREE 90 ELBOWS) (MAXIMUM OF TWO 90 ELBOWS) Special Venting Components (Simpson Duravent) See Empire Comfort Systems Retail Price List for Simpson Duravent part numbers and pricing. Special DV Vent Kits Available from Empire Comfort Systems, Inc. dealers. DVVK-4FV Vertical Flex Vent Kit 4" x 7"...
  • Page 24: Framing And Finishing

    Installing Support Brackets (Figure 37) A horizontal pipe support MUST BE used for each 3 feet of horizontal run. The pipe supports should be placed around the pipe and nailed in place to framing members. There MUST BE a 3 inch clearance to combustibles above 6 5/8 inch diameter pipe and elbows and 1 inch clearance on both sides and bottom of 6 5/8 inch pipe to combustibles on all horizontal pipe sections and elbows.
  • Page 25 FRAMING AND FINISHING (continued) Figure 41 Figure 39 See Horizontal Termination Page 26 and Vertical Termination Pages 31-32. Figure 40 23552-1-0607 Page 25...
  • Page 26: Horizontal Termination

    HORIZONTAL TERMINATION NOTE: Termination cap should pass through the wall firestop from the exterior of the building. Adjust the termination cap to its final exterior position on the building. WARNING: Termination cap must be positioned so that arrow is pointing up. Attach the termination cap with the four wood screws provided.
  • Page 27 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS CAUTION: Sharp edges, use protective gloves when installing. Tools Needed for Installation: Sheet metal snips 5/16” nut driver Phillips head screwdriver - #2 High temperature sealant or furnace cement rated for continuous use at 1,000 F minimum Measuring tape Parts Verification...
  • Page 28: Dvvk-4Re

    DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) VINYL SIDING KIT DV822 OUTSIDE MOUNTING PLATE MEASURE OUTSIDE WALL Figure 3A EXT. WALL SURFACE OR VINYL SIDING KIT FLUE PIPE BEYOND EXTERNAL WALL SURFACE OR VINYL SIDING KIT Figure 3B Page 28 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8”...
  • Page 29 DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) Follow correct option according to venting method. Connecting Directly to Fireplace If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4”...
  • Page 30: Dvvk-4F Flex Vent

    DVVK-4F FLEX VENT INSTRUCTIONS The DVVK-4F FLEX VENT KIT includes the following components: • (1) Horizontal Termination Cap • (1) 4-foot section of Flex vent with spacers (4" flue/7" outer pipe) • (1) 4" dia. Flue adapter collar Flex venting can be installed either vertically or horizontally off of the DVD Series fireplaces. When installing a horizontal vent run from top connections, maintain at least ½"...
  • Page 31: Vertical Termination

    Locate and mark the center point of the vent pipe using a nail on the underside of the roof. Drive the nail through the center point. Mark the outline of the roof hole around this center point. NOTE: Size of the roof hole dimensions depend on the pitch of the roof.
  • Page 32 All damaged gaskets on the glass frame assembly and combustion chamber must be replaced by a qualified service person. If damage occurs to the combustion chamber, it must be replaced by a qualified service person. Contact Empire Comfort Systems, Inc. for replacement parts. Page 32...
  • Page 33: Log Placement

    LOG PLACEMENT (5 LOG SET) Before you begin: if you are installing logs into the DVD32 or DVD36 model then this fireplace is supplied with a set of five ceramic fiber logs. Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation from ceramic fibers.
  • Page 34: Log Placement

    LOG PLACEMENT (7 LOG SET) Before you begin: If you are installing logs into the DVD42 or DVD48 model then this fireplace is supplied with a set of seven ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers.
  • Page 35: Operating Instructions

    OPERATING INSTRUCTIONS 750 Millivolt System The standing pilot (750 millivolt system) is a continuous burning pilot. The pilot remains ON even when the main burner is OFF. When you ignite the pilot, the thermopile produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON.
  • Page 36: Operating Instructions

    OPERATING INSTRUCTIONS (continued) STANDING PILOT OPERATING INSTRUCTIONS REMOTE/OFF/ON Switch The fireplace is equipped with a REMOTE/OFF/ON switch. A wire harness is attached to the REMOTE/OFF/ON switch. The red, black and green (wires) female push-ons attach to the REMOTE/ OFF/ON switch. At the opposite end of the wire harness, the black and green (wires) female push-ons attach to the gas valve.
  • Page 37: Wiring Diagram-Standing Pilot

    STANDING PILOT WIRING DIAGRAM (OPTIONAL) THERMOSTAT (OPTIONAL) WALL SWITCH Figure 57 23552-1-0607 Page 37...
  • Page 38: Lighting Instructions-Standing Pilot

    STANDING PILOT LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.
  • Page 39: Troubleshooting-Standing Pilot

    STANDING PILOT TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
  • Page 40: Wiring Diagram-Direct Ignition

    DIRECT IGNITION WIRING DIAGRAM (OPTIONAL) WALL SWITCH INTERRUPTEUR MURAL (FACULTATIVE) (OPTIONAL) REMOTE CONTROL RECEIVER 120V (FACULATIVE) CONTROLE E DISTANCE DU RECEPTEUR 120 VAC LINE BLACK NOIR 120 VAC RTN WHITE BLANC GREEN VERT JUNCTION BOX JONCTION BOÎTE Steady ON Normal operation, power ON to control 2 Flashes 3 unsuccessful ignition trials 3 Flashes...
  • Page 41: Lighting Instructions-Direct Ignition

    DIRECT IGNITION LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. A. BEFORE LIGHTING smell all around the appliance area for gas.
  • Page 42: Troubleshooting-Direct Ignition

    DIRECT IGNITION TROUBLESHOOTING With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the troubleshooting guide below. This guide will assist a qualified serviceperson in the diagnosis of problems and the corrective action to be taken.
  • Page 43 DIRECT IGNITION PROPANE/LP GAS CONVERSION 1. Turn off the gas supply. 2. Turn off the electrical supply to the appliance if so equipped. 3. Remove top louver and lower bottom louver. 4. Remove glass frame assembly. 5. Remove logs from burner assembly. VALVE CONVERSION 6.
  • Page 44: Maintenance And Service

    MAINTENANCE AND SERVICE PLEASE NOTE It is normal for appliances fabricated of steel to give off some expansion and/or contraction noise during the start up or cool down cycle. Similar noises are found with your furnace heat exchanger or car engine. It is not unusual for your gas fireplace to give off some odor the first time it is burned.
  • Page 45: Parts List

    INDEX NO. PART NUMBER DVD32 DVD36 R-7654 R-7654 17425 17425 R-7566 R-7566 R-7573 R-7573 17155 17155 M163 M163 17142 17142 R-7575 R-7575 17141 17141 R-7574 R-7574 17301 17149 17317 17317 10554 10554 17162 17162 R-3492 R-3492 17169 17127 17172 17134 17170 17128 17174...
  • Page 46: Parts View

    Page 46 PARTS VIEW DIRECT IGNITION BURNER ASSEMBLY 5 PIECE LOG ASSEMBLY 4 PIECE LOG ASSEMBLY MILLIVOLT BURNER ASSEMBLY 7 PIECE LOG ASSEMBLY 5 PIECE LOG ASSEMBLY 23552-1-0607...
  • Page 47: Optional Variable Speed Blower Installation Instructions

    FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Attention: Install blower assembly before connecting gas inlet supply line Note: Junction box on right side of fireplace must be pre-wired at time of fireplace installation for use with blower assembly. It is recommended that an ON/OFF wall switch be installed that will activate the power supply to the furnace by a qualified electrician.
  • Page 48 FBB4 OPTIONAL VARIABLE SPEED BLOWER INSTALLATION Page 48 FBB4 R7649 R4192 R4186 110 VOLT AC JUNCTION BOX BLOWER ASSEMBLY COMPLETE FAN CONTROL SPEED CONTROL KNOB SPEED CONTROL 23552-1-0607...
  • Page 49: Junction Box Wiring Installation Instructions

    JUNCTION BOX WIRING INSTALLATION INSTRUCTIONS STANDARD MILLIVOLT VALVE MODELS CAUTION: ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE MAKING THE ELECTRICAL CONNECTION, MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED.
  • Page 50: Accessories

    The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220-2623. Accessory Fan Kit Simulated Brick Panels...
  • Page 51: How To Order Repair Parts

    Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-2623 23552-1-0607...
  • Page 52: Service Notes

    SERVICE NOTES Empire Comfort Systems, Inc. 918 Freeburg Ave. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 FAX: 618-233-7097 or 800-443-8648 info@empirecomfort.com www.empirecomfort.com Page 52 23552-1-0607...