10-4. kW setup procedure

To set up kW, we advise you not to use DOP/DRW !, use only standard panel.
set C91 "01"
; Debug on
set C94 "D000"
; kW address
set C95 "xx"
; kW code
set B84 "01"
; to execute FACTORY SETTING
Try FACTORY SETTING
Check B12' display (F-23 E-THM LVL)
B12's display table
kW
|
200V | 400V
002
|
1.40 |
004
|
2.60 | 1.50
005,007 |
4.00 | 2.50
011,015 |
7.10 | 3.80
022
| 10.00 | 5.50
030,040 | 15.90 | 8.60
055
| 24.0
075
| 32.0
kW code table (common L100/SJ100)
xx | kW
01 | 002
02 | 004
03 | 005,007
04 | 011,015
05 | 022
06 | 030,040
07 | 055
08 | 075
In case of L100, SJ100, it automatically detects it's voltage class with hardware in the ISPM, voltage class
setup is not necessary.
Meaning
----
| 13.0
| 16.0
10-15