CLEANGUARD WET LOCATION
Page 1 of 2
Features
• UL and C-UL Listed for wet or damp
locations for covered ceiling use.
• Full perimeter gasketing (closed cell Neoprene) between door frame
and lens, between housing and door frame.
• Door frame is post painted, baked
acrylic enamel.
• 5" deep body.
• 81.2% efficient (T8).
• Hemmed over side rails for maximum safety.
• Fixture ends turned-in for safe handling.
• Built-in earthquake clips.
• Slimline door frame with 475 square inch lens opening.
• Mitered corner steel lens frame.
• Spring loaded rooster head latches.
• 18 gauge steel hinges.
• Flat and regressed aluminum doors available.
MOUNTING METHODS
exposed T-grid ceiling.
G
(with flat aluminum frame)
1/4" max.
1-1/2" max.
15/16" or 1"
24"
drywall kit (see options)
Support
Type "G"
(by others)
FIxture
Drywall Kit
(See Options)
Drywall
(by others)
Ceiling Opening
15/16"
24-5/16" x 48-5/16"
earthquake clip
before
installation
2' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE
plaster ceiling/flanged.
F
Plaster
Opening
24-1/8"
1-1/8" min.
3-3/4" max.
13/16"
24-11/16"
gasketing detail
Fixture
Gasketing
(Close Cell Neoprene)
Lens
Door Frame
earthquake clip
installed
(lay-in grid)
WES SERIES 2X4
DIMENSIONS
24" (610mm)
2" x 2-1/2" access plate
6" (152mm)
with two K.O.s
(7/8" dia.)
39-1/4" (997mm)
47-31/32" (1218mm)
Job Information
Job Name:
Cat. No.:
Lamp(s):
Volts/Ballast:
Lightolier
a Genlyte Thomas Company
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
2, 3 OR 4 LAMP, T8 OR T12
5" (127mm)
Type:
www.lightolier.com
SECTION 6/Folio N30-12

Advertisement

loading

Summary of Contents for Lightolier WES SERIES 2X4

  • Page 1 Technical Information: (978) 657-7600 • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2002 Genlyte Thomas Group LLC (Lightolier Division) SECTION 6/Folio N30-12 A0902...
  • Page 2: Specifications

    We reserve the right to change details of design, materials and finish. exceed 3108 candelas per square meter. To control veiling reflections, luminaire © 2002 Genlyte Thomas Group LLC (Lightolier Division) output in the 30°-90° zone shall not be less than 68.6%.

This manual is also suitable for:

2x4 wes series