Motor
Output
Voltage
Applicable Inverter Type
(kW)
*1
0.75
FR-F720-0.75K
1.5
FR-F720-1.5K
2.2
FR-F720-2.2K
3.7
FR-F720-3.7K
5.5
FR-F720-5.5K
7.5
FR-F720-7.5K
11
FR-F720-11K
15
FR-F720-15K
18.5
FR-F720-18.5K
200V class
22
FR-F720-22K
30
FR-F720-30K
37
FR-F720-37K
45
FR-F720-45K
55
FR-F720-55K
75
FR-F720-75K
90
FR-F720-90K
110
FR-F720-110K
0.75
FR-F740-0.75K
1.5
FR-F740-1.5K
2.2
FR-F740-2.2K
3.7
FR-F740-3.7K
5.5
FR-F740-5.5K
7.5
FR-F740-7.5K
11
FR-F740-11K
15
FR-F740-15K
18.5
FR-F740-18.5K
22
FR-F740-22K
30
FR-F740-30K
37
FR-F740-37K
45
FR-F740-45K
55
FR-F740-55K
75
FR-F740-75K
90
FR-F740-90K
400V class
110
FR-F740-110K
132
FR-F740-132K
160
FR-F740-160K
185
FR-F740-185K
220
FR-F740-220K
250
FR-F740-250K
280
FR-F740-280K
315
FR-F740-315K
355
FR-F740-355K
400
FR-F740-400K
450
FR-F740-450K
500
FR-F740-500K
560
FR-F740-560K
*1
Selections for use of the Mitsubishi 4-pole standard motor with power supply voltage 200VAC (200V class)/400VAC (400V class) 50Hz.
*2
Install one MCCB per inverter.
For installations in the United States or Canada, use the fuse certified by the UL and cUL.
(Refer to the Instruction Manual (basics).)
*3
The electrical durability of magnetic contactor is 500,000 times. When the magnetic contactor is used for emergency stop during motor driving, the electrical durability is 25
times.
When using the MC for emergency stop during motor driving or using on the motor side during commercial-power supply operation, select the MC with class AC-3 rated
current for the motor rated current.
*4
Cable
For the 55K or less, the recommended cable size is that of the cable (HIV cable (600V class 2 vinyl-insulated cable) etc.) with continuous maximum permissible temperature
of 75°C. Assumes that the ambient temperature is 50°C or less and the wiring distance is 20m or less.
For the 75K or more, the recommended cable size is that of the cable (LMFC (heat resistant flexible cross-linked polyethylene insulated cable) etc.) with continuous
maximum permissible temperature of 90°C or more. Assumes that the ambient temperature is 50°C or less and wiring is performed in an enclosure.
57
Moulded Case Circuit Breaker (MCCB) *2 or
Earth Leakage Circuit Breaker (ELB)
Reactor connection
without
with
30AF 10A
30AF 10A
30AF 15A
30AF 15A
30AF 20A
30AF 15A
30AF 30A
30AF 30A
50AF 50A
50AF 40A
100AF 60A
50AF 50A
100AF 75A
100AF 75A
225AF 125A
100AF 100A
225AF 150A
225AF 125A
225AF 175A
225AF 150A
225AF 225A
225AF 175A
400AF 250A
225AF 225A
400AF 300A
400AF 300A
400AF 400A
400AF 350A
400AF 400A
400AF 400A
600AF 500A
30AF 5A
30AF 5A
30AF 10A
30AF 10A
30AF 10A
30AF 10A
30AF 20A
30AF 15A
30AF 30A
30AF 20A
30AF 30A
30AF 30A
50AF 50A
50AF 40A
100AF 60A
50AF 50A
100AF 75A
100AF 60A
100AF 100A
100AF 75A
225AF 125A
225AF 100A
225AF 150A
225AF 125A
225AF 175A
225AF 150A
225AF 200A
225AF 175A
225AF 225A
225AF 225A
225AF 225A
400AF 400A
400AF 400A
400AF 400A
600AF 500A
600AF 600A
600AF 600A
800AF 700A
800AF 800A
1000AF 900A
1000AF 1000A
1200AF 1200A
1600AF 1500A
Input Side Magnetic
Contactor
Commercial-power
Reactor connection
supply operation
without
available
30AF 10A
S-N10
S-N10
30AF 15A
S-N10
S-N10
30AF 20A
S-N10
S-N10
30AF 30A
S-N20, N21
S-N10
50AF 50A
S-N25
S-N20, N21
100AF 60A
S-N25
S-N25
100AF 75A
S-N35
S-N35
225AF 125A
S-N50
S-N50
225AF 150A
S-N65
S-N50
225AF 175A
S-N80
S-N65
225AF 225A
S-N95
S-N80
400AF 250A
S-N150
S-N125
400AF 350A
S-N180
S-N150
600AF 500A
S-N220
S-N180
400AF 400A
S-N300
600AF 500A
S-N300
600AF 600A
S-N400
30AF 5A
S-N10
S-N10
30AF 10A
S-N10
S-N10
30AF 15A
S-N10
S-N10
30AF 20A
S-N10
S-N10
30AF 30A
S-N20
S-N11, N12
30AF 30A
S-N20
S-N20
50AF 50A
S-N20
S-N20
100AF 60A
S-N25
S-N20
100AF 75A
S-N25
S-N25
100AF 100A
S-N35
S-N25
225AF 125A
S-N50
S-N50
225AF 150A
S-N65
S-N50
225AF 175A
S-N80
S-N65
225AF 200A
S-N80
S-N80
225AF 225A
S-N95
400AF 300A
S-N150
400AF 350A
S-N180
400AF 400A
S-N220
600AF 500A
S-N300
600AF 500A
S-N300
600AF 600A
S-N400
600AF 600A
S-N600
800AF 800A
S-N600
800AF 800A
S-N600
800AF 800A
S-N600
1000AF 1000A
S-N800
1000A rated
1000AF 1000A
product
1000A rated
1200AF 1200A
product
1200A rated
1600AF 1600A
product
Recommended Cable
2
*3
Size (mm
)
*4
R, S, T
U, V, W
with
2
2
2
2
2
2
3.5
3.5
5.5
5.5
14
8
14
14
22
22
38
38
38
38
60
60
80
80
100
100
100
100
125
125
150
150
2 × 100
2 × 100
2
2
2
2
2
2
2
2
2
2
3.5
3.5
5.5
5.5
8
8
14
8
14
14
22
22
22
22
38
38
60
60
60
60
60
60
80
80
100
125
125
125
150
150
2 × 100
2 × 100
2 × 100
2 × 100
2 × 125
2 × 125
2 × 150
2 × 150
2 × 200
2 × 200
2 × 200
2 × 200
2 × 250
2 × 250
2 × 250
2 × 250
3 × 200
3 × 200
MCCB
INV
IM
MCCB
INV
IM