⋅ The following gives the items which can be monitored by the
cumulative saving power monitor (Pr. 52 = "51").
(The cumulative power monitor data digit can be shifted to the
right by the number set in Pr. 891 Cumulative power monitor digit
shifted times.)
Energy
Saving
Description and Formula
Monitor
Item
Power
Power saving is added up per hour.
saving
Σ (Power saving × ∆t)
amount
Power
Power saving amount represented in terms of
saving
charge
amount
Power saving amount × Pr. 896
charge
Estimated value of annual power saving amount
Annual
Power saving amount
power
saving
Operation time during
amount
power saving totalization
Annual
power
Annual power saving amount represented in
saving
terms of charge
amount
Annual power saving amount × Pr. 896
charge
* The increments vary according to the inverter capacity. (55K or less/75K or
more)
Adjustment of terminal FM
Pr.
C0(900), C1(901)
and AM (calibration)
C0(Pr.900) FM terminal calibration
The operation panel and parameter unit can be used to calibrate
the full scales of the terminals FM and AM.
(1) FM terminal calibration (C0(Pr.900))
⋅ The terminal FM is preset to output pulses. By setting the
Calibraton parameter C0 (Pr. 900), the meter connected to the
inverter can be calibrated by parameter setting without use
of a calibration resistor.
⋅ Using the pulse train output of the terminal FM, a digital
display can be provided by a digital counter. The monitor
value is 1440 pulses/s output at the full-scale value of Pr. 54
FM terminal function selection.
Indicator
1mA full-scale
analog meter
1mA
FM
(+)
(-)
Calibration
resistor
*1
8VDC
SD
Pulse width T1: Adjust using calibration parameter C0
Pulse cycle T2: Set with Pr. 55 (frequency monitor)
Set with Pr.56 (current monitor)
*1
Not needed when the operation panel (FR-DU07) or parameter unit (FR-
PU04) is used for calibration.
Used when calibration must be made near the frequency meter for such a
reason as a remote frequency meter.
However, the frequency meter needle may not deflect to full-scale if the
calibration resistor is connected. In this case, use this resistor and
operation panel or parameter unit together.
(2) AM terminal calibration (C1(Pr.901))
⋅ The AM terminal is factory-set to output 10VDC in the full-
scale state of each monitor item. By setting the calibration
parameter C1 (Pr. 901), the ratio (gain) of the output voltage
can be adjusted to the meter scale. Note that the maximum
output voltage is 10VDC.
Pr.
Refer to the section about Pr. 125, Pr. 126
C2(902) to C7(905)
Parameter for manufacturer setting. Do not set.
Pr.
989
indicates simple mode parameters and
Pr.
Increments
0.01kWh/
0.1kWh*
0.01/0.1*
Pr.899
0.01kWh/
× 24 × 365 ×
100
0.1kWh*
0.01/0.1*
C1(Pr.901) AM terminal calibration
(Digital indicator)
1440 pulse/s(+)
FM
T1
SD
T2
indicates extended parameters. When setting parameters, refer to the instruction manual (applied) and understand instructions.
Pr.
Pr.

Buzzer control of the operation panel

990
Pr.990 PU buzzer control
You can make the buzzer "beep" when you press key of the
operation panel (FR-DU07) and parameter unit (FR-PU04).
Pr.990 Setting
0
1(initial value)
Pr.

PU contrast adjustment

991
Pr.991 PU contrast adjustment
Contrast adjustment of the LCD of the parameter unit (FR-
PU04) can be performed.
Decreasing the setting value makes contrast light.
Pr.991 Setting
0 to 63
Pr.
989, CL, ALLC, Er.CL, PCPY

Parameter clear, parameter copy

Pr.989 Parameter copy alarm release
Pr.CL Parameter clear
Er.CL Alarm history clear
Set "1" in Pr.CL Parameter clear to initialize all parameters.
(Calibration parameters are not cleared.)*
Set "1" in ALLC All parameter clear to initialize all parameters. *
Set "1" in Er.CL Alarm history clear to clear alarm history. *
Parameter settings can be copied to multiple inverters by using
PCPY.
When parameters are copied to the 75K or more inverter from
the 55K or less inverter or vice versa, an
the operation panel.
For the parameters whose setting range differ, set
below after reset.
(-)
Pr.989
setting
PCPY
Setting
0
Cancel
1
Copy the source parameters in the operation panel.
Write the parameters copied to the operation panel to the
2
destination inverter.
3
Verify parameters in the inverter and operation panel.
* Parameters are not cleared when "1" is set in Pr.77 Parameter write selection.
Description
Without buzzer
With buzzer
Description
0 : Light
63 : Dark
ALLC All parameter clear
PCPY Parameter copy
alarm appears on
55K or less
75K or more
10
100
Description
Pr.989
as
46