Congratulations on purchasing the Lumiscope Model 2216 Talking Digital Ear Thermometer! Please be sure to read this manual carefully before using this new state-of- the-art device. Keep this manual handy for reference. Parts Identification: Take Reading “Memo.” Button “Talk” Button...
Page 3
lower thalamus have a common blood vessel. Because of this shared vessel, ear temperature can accurately tell fluctuation of body temperature. How to Use The Ear Thermometer Properly: For children younger than one year, gently pull the ear in an inclined backward direction to straighten the auditory canal before inserting the temperature probe for measurement.
Taking Measurements: 1. Thoroughly clean ear, and apply a clean, new probe cover to thermometer. 2. Insert the temperature probe along the ear canal as deep as is comfortable into the ear, press the “ “ button once to start the measurement and you will hear a single beep.
reading will be overwritten, as will each existing memory with the new reading, as they are taken. 4. For the most accurate temperature readings, wait 10 minutes between consecutive uses. 5. If a measurement falls within measuring range (89.6°F ~ 109.3°F or 32.0°C ~ 42.9°C), the temperature will be displayed.
Clock Mode 1. The 2216 will enter clock mode when the thermometer is on and no key is pressed for more than one minute. 2. The time will be displayed in Year, Month, Date, Day, Hour and Minute, with a flashing “:” for seconds. 3.
Replacing The Battery Tool needed: small screwdriver Remove screw on underside of unit, and remove battery cover. Insert two new ‘AAA’ batteries as shown in figure 2. Replace battery cover, and reinstall screw. Reset Button Hole Figure 2 °C/°F Button Hole...
Troubleshooting: Symptom: Checklist: Solution: No response Is battery dead? Change battery. Is battery in place Check orientation of properly? battery. Battery symbol Low battery Change battery. on screen “Lo” on screen Has the ther- Follow instruction (temperature is mometer been manual for correct below 89.6°F or positioned...
Specifications: Model Number 2216 Power Supply DC3V (‘AAA’ x 2) Power Consumption <0.05W for Talk Function Temperature Sensor IR Sensor Measuring Range 89.6°F ~ 109.3°F (32.0°C ~ 42.9°C) Measuring Accuracy ±0.4°F (±0.2°C) from 96.7°F to 102.2°F (36.0°C to 39.0°C) ±0.5°F (±0.3°C) from 89.6°F to 96.6°F (32.0°C to 35.9°C) ±0.5°F (±0.3°C) from 102.3°F to 109.3°F (39.1°C to 42.9°C)
To obtain warranty service on your Lumiscope Model 2216 Talking Digital Ear Thermometer, please contact the Lumiscope Repair Department at 1-800-672-8293. There is a $15 fee for return shipping and handling.