Operation Safety Instructions; Care Of Your Opener; Maintenance Schedule - Chamberlain 1000SDR 1/3 HP Owner's Manual

1/3 hp 1/2 hp
Table of Contents

Advertisement

IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of severe injury or death to persons:
1. READ AND FOLLOW ALL INSTRUCTIONS.
2. Do not permit children either to operate or to play with the opener. Keep remote control in a location
inaccessible to children.
3. Operate opener only when the door is in full view and free from any obstruction. Keep the door in sight
until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.
CAUTION
4. Check safety reversal system monthly. See page 26. The garage door MUST reverse on contact with a one
inch object (or a 2x4 board laid flat) placed on the floor. If an adjustment is made to one of the controls
(either force or limits of travel), the other control may need to be adjusted also, and the safety reversal
system must be checked. Failure to properly adjust the opener may result in severe injury or death.
5. If possible, use the manual release only when the door is in a closed position. Caution should be taken
whenever the disconnect cord is actuated with the door open. Weak or broken springs may cause the door to
fall rapidly, causing injury or death to persons.
6. KEEP GARAGE DOORS PROPERLY BALANCED. See page 3. An improperly balanced door may not
reverse when required, and could result in severe injury or death. Repairs to cables, spring assemblies and
other hardware must be made by a professional garage door person.
7. Disconnect the electric power to the garage door opener before making any repairs or removing the covers.
Force and Limit Adjustment Controls
8
8
1
7
7
3
5
Kg
FORCE CONTROLS
Weather conditions may cause some minor changes in
door operation requiring some re-adjustments,
particularly during the first year of operation.
Pages 24 and 25 refer to the limit and force adjustments.
Only a screwdriver is required. Follow the instructions
carefully.
Repeat the safety reverse test (page 26) after any
adjustment of limits or force.
Once a Month
Manually operate door. If it is unbalanced or binding,
call for professional garage door service.
Check to be sure door opens & closes fully. Adjust
limits and/or force if necessary. (See pages 24 & 25.)
WARNING
CAUTION
SAVE THESE INSTRUCTIONS

Care of Your Opener

1
3
5
Kg
+
LIMIT CONTROLS

Maintenance Schedule

WARNING
The Remote Control Transmitter
The opener must learn the code of any new remote
control. Page 29 explains how to program your receiver
and how to erase all codes if required. Self service of
+
your receiver and remote controls is not recommended. If
service is needed, call the toll-free number listed on the
back page.
The yellow test light will glow and the opener will
operate when the remote control is activated, as long as
there is adequate battery power.
If the power indicator light is dim or off, replace the
battery. Also check the test light if transmission range
decreases.
The 12 volt battery should produce power for at least a
year.
Dispose of your old battery properly.
Repeat the safety reverse test. Make any necessary
adjustments (See page 26).
Oil door rollers, bearings and hinges. The opener does
not require additional lubrication. Do not grease the door
tracks.
27
WARNING
The Transmitter Battery
Once a Year

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents