Runtime Menu Description - Carrier PRO-DIALOG Plus 30GK Series Installation, Operation & Maintenance Instructions Manual

Air-cooled liquid chillers
Table of Contents

Advertisement

4.5.10 - Runtime menu description

RUNTIMES 1
[runtiMES 1]
NOTE: The items in brackets show what is displayed on the
user interface.
4.5.10.1 - Description of the Runtimes 1 menu
RUNTIMES MENU [1]
iTEM # FORMAT
UNIT
0
-
-
1
nnnn | M 10 | M100
hrs/10 or 100
2
nnnn | M 10 | M100
hrs/10 or 100
3 [1]
nnnn | M 10 | M100
hrs/10 or 100
4 [1]
nnnn | M 10 | M100
hrs/10 or 100
5 [1]
nnnn | M 10 | M100
hrs/10 or 100
6 [1]
nnnn | M 10 | M100
hrs/10 or 100
7 [1]
nnnn | M 10 | M100
hrs/10 or 100
8 [1]
nnnn | M 10 | M100
hrs/10 or 100
9 [1]
nnnn | M 10 | M100
hrs/10 or 100
10
nnnn | M 10 | M100
-/10 or 100
11
nnnn | M 10 | M100
-/10 or 100
12 [1]
nnnn | M 10 | M100
-/10 or 100
13 [1]
nnnn | M 10 | M100
-/10 or 100
14 [1]
nnnn | M 10 | M100
-/10 or 100
15 [1]
nnnn | M 10 | M100
-/10 or 100
16 [1]
nnnn | M 10 | M100
-/10 or 100
17 [1]
nnnn | M 10 | M100
-/10 or 100
18 [1]
nnnn | M 10 | M100
-/10 or 100
NOTES
1
This item is masked when not used
*
Certain values are divided by 10 or by 100, so that number of hours or start-
ups of less then 10 are displayed as 0.
When the value is divided by 10 or by 100 it is displayed in turn with "M 10" or
"M100".
26
RUNTIMES
RUNTIMES 2
MAINTENANCE
[runtiMES 2]
[MAintEnAnCE]
COMMENTS
When selected this item
authorises return to the previous
menu
Unit operating hours*
Compressor A1 operating hours*
Compressor A2 operating hours*
Compressor A3 operating hours*
Compressor A4 operating hours*
Compressor B1 operating hours*
Compressor B2 operating hours*
Compressor B3 operating hours*
Compressor B4 operating hours*
Machine starts*
Compressor A1 starts*
Compressor A2 starts*
Compressor A3 starts*
Compressor A4 starts*
Compressor B1 starts*
Compressor B2 starts*
Compressor B3 starts*
Compressor B4 starts*
4.5.10.2 - Description of the Runtimes 2 menu
RUNTIMES MENU [2]
iTEM # FORMAT
UNIT
0
-
-
1
nnnn | M 10 | M100
hrs/10 or 100
2
nnnn | M 10 | M100
hrs/10 or 100
3 [1]
nnnn | M 10 | M100
hrs/10 or 100
4 [1]
nnnn
-
5
nnnn
-
4.5.10.3 - Maintenance menu description
To be active, the maintenance function must be preset in the
Service configuration.
ITEM # FORMAT
DESCRIPTION
0
MAintEnAnCE MEnu When selected this item authorises return to the
previous menu.
1 [1]
Accessible with the Service password.
2 [1]
For future use
3 [1]
For future use
4 [1]
ALErt
Water loop rate to low
5 [1]
nnn/ALErt
Next primary pump maintenance operation in nnn
days. 'ALErt' is displayed, when the delay before
maintenance has elapsed.
6 [1]
nnn/ALErt
Next secondary pump maintenance operation in
nnn days. 'ALErt' is displayed, when the delay
before maintenance has elapsed.
7 [1]
nnn/ALErt
Next water filter maintenance operation in nnn
days. 'ALErt' is displayed, when the delay before
maintenance has elapsed.
Legend
1 This item is masked when not used.
COMMENTS
When selected this item
authorises return to the previous
menu
Pump #1 operating hours*
Pump #2 operating hours*
Condenser pump operating
hours
Number of start-ups for the
compressor with the highest
number during the last hour
Average number of compressor
start-ups/hour for the last 24
hours

Hide quick links: