Bryant 355MAV Installation, Start-Up, And Operating Instructions Manual page 27

Series h deluxe 4-way multipoise variable-capacity direct vent condensing gas furnace
Table of Contents

Advertisement

UNIT
ALTITUDE
SIZE
042040
042060
042080
6001 to 7000‡
060080
060100
060120
Unit
Altitude
Size
042040
042060
042080
7001 to 8000‡
060080
060100
060120
Unit
Altitude
Size
042040
042060
042080
8001 to 9000‡
060080
060100
060120
Unit
Altitude
Size
042040
042060
042080
9001 to 10000‡
060080
060100
060120
* Disk usage—Unless otherwise stated, use perforated disk assembly (factory-supplied in loose parts bag).
† Wide radius elbow.
‡ Vent sizing for Canadian installations over 4500 ft (1370m) above sea level are subject to acceptance by the local authorities having jurisdiction.
NA—Not Allowed; pressure switch will not make.
NOTES:
1. Do not use pipe size greater than those specified in table or incomplete combustion, flame disturbance, or flame sense lockout may occur.
2. Size both the combustion-air and vent pipe independently, determine the smallest diameter allowed by the table for each pipe, then use the larger diameter for both pipes.
3. Assume two 45° elbows equal one 90° elbow. Long radius elbows are desirable and may be required in some cases.
4. Elbows and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
5. The minimum pipe length is 5 ft for all applications.
TABLE 7—MAXIMUM ALLOWABLE PIPE LENGTH (FT)
TERMINATION
TYPE
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 3-In.
Concentric
Termination
Type
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 3-In.
Concentric
Termination
Type
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 3-In.
Concentric
Termination
Type
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 2-In.
Concentric
2 Pipe or 3-In.
Concentric
PIPE DIAMETER
(IN.)*
1
1-1/2
35
2
70
1-1/2
35
2
70
1-1/2
20
2
70
2
31
2-1/2
70
3†
49
Pipe Diameter
(In.)*
1
1-1/2
32
2
66
1-1/2
32
2
66
1-1/2
18
2
66
2
29
2-1/2
66
3†
46
Pipe Diameter
(In.)*
1
1-1/2
30
2
62
1-1/2
30
2
62
1-1/2
17
2
62
2
27
2-1/2
62
3†
43
Pipe Diameter
(In.)*
1
1-1/2
27
2
57
1-1/2
27
2
57
1-1/2
15
2
57
2
24
2-1/2
57
3†
39
—27—
Continued
NUMBER OF 90° ELBOWS
2
3
4
30
25
20
15
70
68
67
66
30
25
20
15
70
68
67
66
15
10
5
NA
70
68
67
62
26
21
16
11
70
68
67
66
48
47
45
44
Number of 90° Elbows
2
3
4
27
22
17
12
65
63
62
60
27
22
17
12
65
63
62
60
13
8
NA
NA
65
63
62
57
24
19
14
65
63
62
60
44
43
41
40
Number of 90° Elbows
2
3
4
25
20
15
10
60
58
56
55
25
20
15
10
60
58
56
55
12
7
NA
NA
60
58
56
51
22
17
12
60
58
56
55
41
39
37
35
Number of 90° Elbows
2
3
4
22
17
12
55
53
51
49
22
17
12
55
53
51
49
10
5
NA
NA
55
53
51
46
19
14
9
NA
55
53
51
49
37
35
33
31
5
6
10
64
10
64
NA
57
6
64
43
5
6
7
59
7
59
NA
52
9
NA
59
38
5
6
5
53
5
53
NA
46
7
NA
53
34
5
6
7
NA
47
7
NA
47
NA
41
NA
47
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Series h

Table of Contents