SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance,
or use can cause explosion, fire, electrical shock, or other
conditions which may cause death, personal injury, or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The qualified
installer or agency must use factory- -authorized kits or accessories
when modifying this product. Refer to the individual instructions
packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing,
and work gloves. Use quenching cloth for brazing operations.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions included in
literature and attached to the unit. Consult local building codes and
current editions of the National Electrical Code ( NEC ) NFPA 70.
In Canada, refer to current editions of the Canadian electrical code
CSA 22.1.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the unit and in instructions or
manuals, be alert to the potential for personal injury. Understand
these signal words; DANGER, WARNING, and CAUTION. These
words are used with the safety- -alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury
or death. WARNING signifies hazards which could result in
personal injury or death. CAUTION is used to identify unsafe
practices which would result in minor personal injury or product
and property damage. NOTE is used to highlight suggestions
which will result in enhanced installation, reliability, or operation.
WARNING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing, modifying, or servicing system, main
electrical disconnect switch must be in the OFF position and
install a lockout tag. There may be more than 1 disconnect
switch. Lock out and tag switch with a suitable warning label.
CAUTION
!
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and
wear appropriate protective clothing and gloves when
handling parts.

Installation Instructions

Indoor Thermostat Control Options
Model
187B / 180B

INSTALLATION RECOMMENDATIONS

NOTE: In some cases noise in the living area has been traced to
gas pulsations from improper installation of equipment.
1. Locate unit away from windows, patios, decks, etc. where
unit operation sound may disturb customer.
2. Ensure that vapor and liquid tube diameters are appropriate
for unit capacity.
3. Run refrigerant tubes as directly as possible by avoiding un-
necessary turns and bends.
! !
4. Leave some slack between structure and unit to absorb vi-
bration.
5. When passing refrigerant tubes through the wall, seal open-
ing with RTV or other pliable silicon- -based caulk. (See Fig.
1.)
6. Avoid direct tubing contact with water pipes, duct work,
floor joists, wall studs, floors, and walls.
7. Do not suspend refrigerant tubing from joists and studs with
a rigid wire or strap which comes in direct contact with
tubing.(See Fig. 1.)
8. Ensure that tubing insulation is pliable and completely sur-
rounds vapor tube.
9. When necessary, use hanger straps which are 1 in. (25.4
mm) wide and conform to shape of tubing insulation. (See
Fig. 1.)
10. Isolate hanger straps from insulation by using metal sleeves
bent to conform to shape of insulation.
NOTE:
Avoid contact between tubing and structure
OUTDOOR WALL
HANGER STRAP
(AROUND VAPORTUBE ONLY)
1" (25.4 mm) MIN.
Fig. 1 - - Piping Installation
Standard
Evolution
2---stage
Control
Thermostat
Yes
INDOOR WALL
CAULK
LIQUID TUBE
VAPOR TUBE
INSULATION
THROUGH THE WALL
JOIST
INSULATION
VAPOR TUBE
LIQUID TUBE
SUSPENSION
Yes
A94026

Advertisement

Table of Contents
loading

Summary of Contents for Bryant EVOLUTION 187B

  • Page 1: Installation Instructions

    187B (2 - - 5 TONS) 180B (3 TON TROPHY) EVOLUTIONt SERIES 2- -STAGE AIR CONDITIONER WITH PURON REFRIGERANT Installation Instructions SAFETY CONSIDERATIONS Indoor Thermostat Control Options Standard Improper installation, adjustment, alteration, service, maintenance, Evolution Model 2---stage Control or use can cause explosion, fire, electrical shock, or other Thermostat conditions which may cause death, personal injury, or property damage.
  • Page 2: Operating Ambient

    Make Piping Connections The outdoor unit contains system refrigerant charge for operation with AHRI rated indoor unit when connected by 15 ft. (4.57 m) of WARNING field- -supplied or factory accessory tubing. For proper unit operation, check refrigerant charge using charging information located on control box cover and/or in the Check Charge section of PERSONAL INJURY AND ENVIRONMENTAL this instruction.
  • Page 3 Table 1 – Accessory Usage REQUIRED FOR REQUIRED FOR SEA COAST LOW --- AMBIENT COOLING REQUIRED FOR LONG LINE ACCESSORY APPLICATIONS APPLICATIONS APPLICATIONS* (Within 2 miles/3.22 km) (Below 55°F/12.8_C) Compressor Start Assist Kit Crankcase Heater Standard Standard Standard Standard with Evolutiont Control Evaporator Freeze Protection (Low Ambient not allowed with non ---communicating thermostat)
  • Page 4 Make Electrical Connections Refer to Fig. 3 and install filter drier as follows: 1. Braze 5- -in. liquid tube to the indoor coil. Be sure field wiring complies with local and national fire, safety, 2. Wrap filter drier with damp cloth. and electrical codes, and voltage to system is within limits shown on unit rating plate.
  • Page 5 Final Wiring Check quired airflow shown in the air conditioning Product Data for LOW speed. If a higher or lower continuous fan speed is IMPORTANT: Check factory wiring and field wire connections desired, the continuous fan speed can be changed using the to ensure terminations are secured properly.
  • Page 6 Communication and Status Function Lights Outdoor Fan Motor Operation For Evolution Control Only, Green communications The outdoor unit control energizes the outdoor fan any time the compressor is operating except for low- -ambient cooling operation. (COMM)Light The outdoor fan remains energized if a pressure switch or Green LED (COMM Light) compressor overload should open.
  • Page 7 MODEL PLUG MODEL PLUG UTILITY RELAY UTILITY SIGNAL OPEN RELAY SUPPLIED BY UTILITY PROVIDER Liquid Line Solenoid A06526 Fig. 6 - - 2- -Stage Control Board Evolution Controlled Low Ambient Cooling Check Charge This unit is capable of low ambient cooling down to 0_F Models 180B / 187B should be charged in high stage compressor (- -17.78_C) without a kit - - ONLY when using Evolution control.
  • Page 8: Care And Maintenance

    Final Checks CARE AND MAINTENANCE IMPORTANT: Before leaving job, be sure to do the following: For continuing high performance and to minimize possible equipment failure, periodic maintenance must be performed on this 1. Ensure that all wiring is routed away from tubing and sheet equipment.
  • Page 9: System Communications Failure

    TROUBLESHOOTING Control Fault If the outdoor unit control board has failed, the control will flash If the compressor fails to operate with a cooling call, Table 4 can be the appropriate fault code. (See Table 6) The control board should used to verify if there is any damage to the compressor windings be replaced.
  • Page 10: No 230V At Compressor

    2- -Stage Compressor cutout trips for three consecutive cycles, then unit operation is locked out for 4 hours and the appropriate fault code is displayed. The 2- -stage compressor contains motor windings that provide No 230V at Compressor 2- -pole (3500 RPM) operation. Refer to Table 4 for correct winding resistance.
  • Page 11 OAT Thermistor must be OCT Thermistor must be locked in place with spherical secured tight on the liquid tube. nib end facing towards the front of the control box Fig. 9 - - Outdoor Coil Thermistor (OCT) Attachment Fig. 8 - - Outdoor Air Thermistor (OAT) Attachment Table 6 –...
  • Page 12 Two-Stage Variable Speed Variable Speed 2-Stage Thermidistat Air Conditioner Furnace Fan Coil Air Conditioner Thermidistat Heat Stage 2 O/B W2 RVS/Heat Stage 2 O/W2/B Heat Stage 1 W/W1 Heat Stage 1 W/W1 REMOVE J2 JUMPER FOR Cool Stage 1 Y1 / W2 Compressor Low HEAT STAGING Cool Stage 2...
  • Page 13 PURONR (R- -410A) REFRIGERANT QUICK REFERENCE GUIDE S Puron refrigerant operates at 50- -70 percent higher pressures than R- -22. Be sure that servicing equipment and replacement components are designed to operate with Puron refrigerant S Puron refrigerant cylinders are rose colored. S Recovery cylinder service pressure rating must be 400 psig, DOT 4BA400 or DOT BW400.
  • Page 14 Catalog No. II180---187B---01 E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/10 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

This manual is also suitable for:

Evolution 180b

Table of Contents